skip to main content


Title: One-Step Fabrication of Stimuli-Responsive Chitosan-Platinum Brushes for Listeria monocytogenes Detection
Bacterial contamination in food-processing facilities is a critical issue that leads to outbreaks compromising the integrity of the food supply and public health. We developed a label-free and rapid electrochemical biosensor for Listeria monocytogenes detection using a new one-step simultaneous sonoelectrodeposition of platinum and chitosan (CHI/Pt) to create a biomimetic nanostructure that actuates under pH changes. The XPS analysis shows the effective co-deposition of chitosan and platinum on the electrode surface. This deposition was optimized to enhance the electroactive surface area by 11 times compared with a bare platinum–iridium electrode (p < 0.05). Electrochemical behavior during chitosan actuation (pH-stimulated osmotic swelling) was characterized with three different redox probes (positive, neutral, and negative charge) above and below the isoelectric point of chitosan. These results showed that using a negatively charged redox probe led to the highest electroactive surface area, corroborating previous studies of stimulus–response polymers on metal electrodes. Following this material characterization, CHI/Pt brushes were functionalized with aptamers selective for L. monocytogenes capture. These aptasensors were functional at concentrations up to 106 CFU/mL with no preconcentration nor extraneous reagent addition. Selectivity was assessed in the presence of other Gram-positive bacteria (Staphylococcus aureus) and with a food product (chicken broth). Actuation led to improved L. monocytogenes detection with a low limit of detection (33 CFU/10 mL in chicken broth). The aptasensor developed herein offers a simple fabrication procedure with only one-step deposition followed by functionalization and rapid L. monocytogenes detection, with 15 min bacteria capture and 2 min sensing.  more » « less
Award ID(s):
1805512
NSF-PAR ID:
10385431
Author(s) / Creator(s):
; ; ;
Date Published:
Journal Name:
Biosensors
Volume:
11
Issue:
12
ISSN:
2079-6374
Page Range / eLocation ID:
511
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. Abstract

    In this work, we demonstrate the development of a rapid and label-free electrochemical biosensor to detectListeria monocytogenesusing a novel stimulus–response thiomer nanobrush material. Nanobrushes were developed via one-step simultaneous co-deposition of nanoplatinum (Pt) and alginate thiomers (ALG-thiomer). ALG-thiomer/Pt nanobrush platform significantly increased the average electroactive surface area of electrodes by 7 folds and maintained the actuation properties (pH-stimulated osmotic swelling) of the alginate. Dielectric behavior during brush actuation was characterized with positively, neutral, and negatively charged redox probes above and below the isoelectric point of alginate, indicating ALG-thiomer surface charge plays an important role in signal acquisition. The ALG-thiomer platform was biofunctionalized with an aptamer selective for the internalin A protein onListeriafor biosensing applications. Aptamer loading was optimized and various cell capture strategies were investigated (brush extended versus collapsed). Maximum cell capture occurs when the ALG-thiomer/aptamer is in the extended conformation (pH > 3.5), followed by impedance measurement in the collapsed conformation (pH < 3.5). Low concentrations of bacteria (5 CFU mL−1) were sensed from a complex food matrix (chicken broth) and selectivity testing against other Gram-positive bacteria (Staphylococcus aureus) indicate the aptamer affinity is maintained, even at these pH values. The new hybrid soft material is among the most efficient and fastest (17 min) forL. monocytogenesbiosensing to date, and does not require sample pretreatment, constituting a promising new material platform for sensing small molecules or cells.

     
    more » « less
  2. null (Ed.)
    Irrigation water is a primary source of fresh produce contamination by bacteria during the preharvest, particularly in hydroponic systems where the control of pests and pathogens is a major challenge. In this work, we demonstrate the development of a Listeria biosensor using platinum interdigitated microelectrodes (Pt-IME). The sensor is incorporated into a particle/sediment trap for the real-time analysis of irrigation water in a hydroponic lettuce system. We demonstrate the application of this system using a smartphone-based potentiostat for rapid on-site analysis of water quality. A detailed characterization of the electrochemical behavior was conducted in the presence/absence of DNA and Listeria spp., which was followed by calibration in various solutions with and without flow. In flow conditions (100 mL samples), the aptasensor had a sensitivity of 3.37 ± 0.21 kΩ log-CFU−1 mL, and the LOD was 48 ± 12 CFU mL−1 with a linear range of 102 to 104 CFU mL−1. In stagnant solution with no flow, the aptasensor performance was significantly improved in buffer, vegetable broth, and hydroponic media. Sensor hysteresis ranged from 2 to 16% after rinsing in a strong basic solution (direct reuse) and was insignificant after removing the aptamer via washing in Piranha solution (reuse after adsorption with fresh aptamer). This is the first demonstration of an aptasensor used to monitor microbial water quality for hydroponic lettuce in real time using a smartphone-based acquisition system for volumes that conform with the regulatory standards. The aptasensor demonstrated a recovery of 90% and may be reused a limited number of times with minor washing steps. 
    more » « less
  3. Foodborne pathogens are a major concern for public health. We demonstrate for the first time a partially automated sensing system for rapid (~17 min), label-free impedimetric detection of Escherichia coli spp. in food samples (vegetable broth) and hydroponic media (aeroponic lettuce system) based on temperature-responsive poly(N-isopropylacrylamide) (PNIPAAm) nanobrushes. This proof of concept (PoC) for the Sense-Analyze-Respond-Actuate (SARA) paradigm uses a biomimetic nanostructure that is analyzed and actuated with a smartphone. The bio-inspired soft material and sensing mechanism is inspired by binary symbiotic systems found in nature, where low concentrations of bacteria are captured from complex matrices by brush actuation driven by concentration gradients at the tissue surface. To mimic this natural actuation system, carbon-metal nanohybrid sensors were fabricated as the transducer layer, and coated with PNIPAAm nanobrushes. The most effective coating and actuation protocol for E. coli detection at various temperatures above/below the critical solution temperature of PNIPAAm was determined using a series of electrochemical experiments. After analyzing nanobrush actuation in stagnant media, we developed a flow through system using a series of pumps that are triggered by electrochemical events at the surface of the biosensor. SARA PoC may be viewed as a cyber-physical system that actuates nanomaterials using smartphone-based electroanalytical testing of samples. This study demonstrates thermal actuation of polymer nanobrushes to detect (sense) bacteria using a cyber-physical systems (CPS) approach. This PoC may catalyze the development of smart sensors capable of actuation at the nanoscale (stimulus-response polymer) and macroscale (non-microfluidic pumping). 
    more » « less
  4. A systematic study of electrochemically roughened (ECR) thin film platinum (Pt) microelectrodes for glutamate, GLU (a major excitatory neurotransmitter) detection is presented. Scanning electron microscopy, energy dispersive spectroscopy, surface profilometry, electrochemical impedance spectroscopy and amperometry techniques were applied to investigate the effect of high-frequency electrical pulses on Pt microelectrode roughness, electroactive area, charge transfer resistance, and sensitivity and selectivity to hydrogen peroxide, a by-product of enzymatic biosensors and GLU. An increase in the mean surface roughness from 9.0 ± 0.5 to 116.3 ± 7.4 nm (n = 3) was observed which resulted in a 55 ± 2% (n = 3) increase in the electroactive area. An ECR microelectrode treated at +1.4 V and coated with a selective coating produced a GLU selectivity value of 342 ± 34 (n = 3) vs ascorbic acid and the highest GLU sensitivity of 642 ± 45 nAμM−1cm−2(n = 3) when compared to other surface-treated Pt microelectrodes reported in the literature. An impedance model was created to elucidate the microstructural and electrochemical property changes to the ECR microelectrodes. The ECR surface comprises of uniformly distributed homogenous pores with very low impedance, which is ∼6-times lower when compared to a methanol cleaned electrode. The model could lay a foundation for the rational designing of biosensors for enhanced neurotransmitter detection.

     
    more » « less
  5. Parvinzadeh Gashti, Mazeyar (Ed.)
    The simple, accurate, and rapid detection of foodborne pathogens is essential for public health. Development of an immunomagnetic separation (IMS) multiplex touchdown PCR (IMS–multiplex TD–PCR) assay for simultaneous detection and distinguishing of C. jejuni and C. coli is reported herein. Polyclonal antibody (pAb) against multiepitope antigen (MEA) was conjugated to ferromagnetic nanoparticles (FMNs) to produce anti-MEA FMNs. Optimal anti-MEA FMNs loading yielded 26.7 μg of immunoglobulin G (IgG) molecules per mg of FMNs with an average size of 72 ± 9  nm, corresponding to an 83% rate of pAb conjugation. Anti-MEA FMNs (20 μg) for IMS captured culturable C. jejuni cells at 3.54 × 10 2 colony-forming unit (CFU)/mL in pure culture, while higher amounts (40 and 60 μg) reduced the recovery. The scanning electron microscope (SEM) analysis revealed the attachment of anti-MEA FMNs to target bacteria, forming aggregated cells and magnetic nanoparticles in ellipse-like shapes. The subsequent multiplex TD–PCR assay simultaneously detected and distinguished C. jejuni and C. coli at 104 CFU/mL in mixed culture and at 103 CFU/mL for each individual species. Furthermore, the limit of detection (LOD) of the IMS–multiplex TD–PCR assay was 104 CFU/g in spiked chicken breast samples. Specificity was 100% for both C. jejuni and C. coli as none of the amplicons were detected in control samples where Campylobacter was absent. This assay is able to detect and distinguish C. jejuni and C. coli simultaneously and is simple, accurate, and rapid with a time to result of 4 h without an enrichment step, making it a promising approach for rapid and culture-free detection of Campylobacter in chicken products. 
    more » « less