Title: Integration of microlenses on surface-micromachined optical ultrasound transducer array to improve detection sensitivity for parallel data readout
This Letter reports the integration of microlenses (MLs) on a surface-micromachined optical ultrasound transducer (SMOUT) array to enable parallel ultrasound data readout from a multiplicity of elements. The MLs are fabricated by photoresist patterning and reflow, and their focal lengths are optimized with parametric studies. Experiments are conducted to characterize the acoustic responsivity and its uniformity of the SMOUT-ML elements under different conditions. The temporal stability of SMOUT-ML elements immersed in water is assessed by monitoring their acoustic response continuously for 1 week. Parallel ultrasound signal readout is simulated with a small group of SMOUT-ML elements. Experimental results show that high acoustic sensitivity and excellent long-term stability can be achieved by the ML-integrated SMOUT array, which could provide a promising approach for enabling parallel ultrasound data acquisition for improving the imaging speed of 3D acoustic tomography.  more » « less
Award ID(s):
1852184 2036134
PAR ID:
10392826
Author(s) / Creator(s):
;
Publisher / Repository:
Optical Society of America
Date Published:
Journal Name:
Optics Letters
Volume:
48
Issue:
3
ISSN:
0146-9592; OPLEDP
Format(s):
Medium: X Size: Article No. 652
Size(s):
Article No. 652
Sponsoring Org:
National Science Foundation
More Like this
  1. This article reports the fine-tuning of the optical resonance wavelength (ORW) of surface-micromachined optical ultrasound transducer (SMOUT) arrays to enable ultrasound data readout with non-tunable interrogation light sources for photoacoustic computed tomography (PACT). Permanent ORW tuning is achieved by material deposition onto or subtraction from the top diaphragm of each element with sub-nanometer resolution. For demonstration, a SMOUT array is first fabricated, and its ORW is tuned for readout with an 808 nm laser diode (LD). Experiments are conducted to characterize the optical and acoustic performances of the elements within the center region of the SMOUT array. Two-dimensional and three-dimensional PACT (photoacoustic computed tomography) is also performed to evaluate the imaging performance of the ORW-tuned SMOUT array. The results show that the ORW tuning does not degrade the optical, acoustic, and overall imaging performances of the SMOUT elements. As a result, the fine-tuning method enables new SMOUT-based PACT systems that are low cost, compact, powerful, and even higher speed, with parallel readout capability. 
    more » « less
  2. This paper reports a new 2D surface-micromachined optical ultrasound transducer (SMOUT) array consisting of 350 × 350 elements with highly uniform optical and acoustic performances. Each SMOUT element consists of a vacuum-sealed Fabry-Perot (F-P) interferometric cavity formed by two parallel partially reflective distributed Bragg reflectors (DBRs). Optical mapping in the 4 cm × 4 cm center region of the SMOUT array shows that the optical resonance wavelength (ORW) of > 94% of the elements falls within a narrow range of ≤ 10 nm. The center frequency, acoustic bandwidth and noise equivalent pressure (NEP) of the elements are determined to be 5 MHz, 5 MHz, and 20.7 Pa (with 16 times of signal averaging) or 172.5 Pa (without averaging) over a bandwidth of 10 MHz, respectively. The temperature and temporal stability of the SMOUT elements is also tested, which shows there is little variation in their ORW under large ambient temperature fluctuation and during continuous water immersion. To demonstrate its imaging capability, 2D and 3D PACT based on the SMOUT array is also conducted within a 3 cm × 3 cm field of view (FOV) at a depth of 3cm with no interrogation wavelength tuning. These results show that the SMOUT array could overcome some of the major limitations in existing ultrasound transducer arrays for PACT and provide a promising solution for achieving high-speed 3D imaging. 
    more » « less
  3. This Letter reports a new, to the best of our knowledge, high-frequency surface-micromachined optical ultrasound transducer (HF-SMOUT) array for micro photoacoustic computed tomography (µPACT). An 11 × 11 mm22D array of 220 × 220 elements (35 µm in diameter) is designed, fabricated, and characterized. The optical resonance wavelength (ORW) of ≥90% of the elements falls within a 6-nm range. The acoustic center frequency and bandwidth of the elements are ∼14 MHz and ∼18 MHz (129%), respectively. The noise equivalent pressure (NEP) is 161 Pa (or 18 mPa/Hz) within a measurement bandwidth of 5–75 MHz. The standard deviation of the ORW drift is 0.45 nm and 0.93 nm within 25°C−55°C, respectively, and during a seven-day continuous water immersion. PACT experiments are conducted to evaluate the imaging performances of the HF-SMOUT array. The spatial resolution is estimated as 90 µm (axial) and 250–750 µm (lateral) within a 10 × 10 mm2field of view (FoV) and the imaging depth of 16 mm. A 3D PA image of a knotted black hair target is also successfully acquired. These results demonstrate the feasibility of using the HF-SMOUT array for µPACT applications. 
    more » « less
  4. Abstract Ultrasound is a safe, noninvasive diagnostic technique used to measure internal structures such as blood vessels and the velocity of blood flow in the human body. The ability to continuously measure blood flow in major cerebral arteries would enable the early detection of medical problems such as stroke. However, current ultrasound technology consists of rigid, hand-held probes that are arduous to use, sensitive to movement, and are primarily designed for intermittent, instead of continuous use. Here, we describe the design of a wearable ultrasound patch for continuously measuring blood flow velocity through the middle cerebral artery (MCA) that can be assessed from the temple region of the head. The wearable ultrasound patch is composed of an array of piezoelectric elements that are wired together using flexible electrical conductors and encapsulated in an elastic substrate. To improve ultrasound energy transfer, a soft and conformal composite matching layer is introduced. The matching layer consists of gallium-based liquid metal (LM) microdroplets dispersed in a silicone elastomer. The acoustic impedance of the matching layer can be tuned by varying the volume loading of LM. The wearable ultrasound patch will provide new opportunities to continuously measure blood flow velocity and ultimately enable early detection of medical problems such as stroke. 
    more » « less
  5. Abstract Painless, needleless delivery of drugs through the skin can be realized through aphenomenon called sonophoresis by applying an ultrasound field to the biological tissue. Development of wearable embodiments of such systems demands comprehensive characterization of both the physical mechanism of sonophoresisas well as wearability parameters. Here, we present a framework for analyzing disk‐type piezoelectric transducers in a polymeric substrate to create acoustic cavitation in a fluid coupling medium for sonophoresis applications. The device design and operating parameters such as the working frequency, applied voltage range, acoustic pressure distribution, and transducer spacing were determine dusing a finite element methods (FEM),and verified with experimental measurements. The influence of the surrounding water and tank reflections on the acoustic pressure field, and the interaction between the elements in the array structure were also studied.Finally, the impact of skin and the substrate geometry on the acoustic pressure fields was characterized to simulate the invivo use‐case of the system. These analytical models can be used to guide critical parameters for device design such as the separation distance of the piezoelectric transducer from the skin boundary. We envision that this tool boxwill support rapid design iteration for realization of wearable ultrasound systems. 
    more » « less