This Letter reports a new, to the best of our knowledge, high-frequency surface-micromachined optical ultrasound transducer (HF-SMOUT) array for micro photoacoustic computed tomography (µPACT). An 11 × 11 mm22D array of 220 × 220 elements (35 µm in diameter) is designed, fabricated, and characterized. The optical resonance wavelength (ORW) of ≥90% of the elements falls within a 6-nm range. The acoustic center frequency and bandwidth of the elements are ∼14 MHz and ∼18 MHz (129%), respectively. The noise equivalent pressure (NEP) is 161 Pa (or 18 mPa/Hz) within a measurement bandwidth of 5–75 MHz. The standard deviation of the ORW drift is 0.45 nm and 0.93 nm within 25°C−55°C, respectively, and during a seven-day continuous water immersion. PACT experiments are conducted to evaluate the imaging performances of the HF-SMOUT array. The spatial resolution is estimated as 90 µm (axial) and 250–750 µm (lateral) within a 10 × 10 mm2field of view (FoV) and the imaging depth of 16 mm. A 3D PA image of a knotted black hair target is also successfully acquired. These results demonstrate the feasibility of using the HF-SMOUT array for µPACT applications.
more »
« less
Fine-Tuning of Optical Resonance Wavelength of Surface-Micromachined Optical Ultrasound Transducer Arrays for Single-Wavelength Light Source Readout
This article reports the fine-tuning of the optical resonance wavelength (ORW) of surface-micromachined optical ultrasound transducer (SMOUT) arrays to enable ultrasound data readout with non-tunable interrogation light sources for photoacoustic computed tomography (PACT). Permanent ORW tuning is achieved by material deposition onto or subtraction from the top diaphragm of each element with sub-nanometer resolution. For demonstration, a SMOUT array is first fabricated, and its ORW is tuned for readout with an 808 nm laser diode (LD). Experiments are conducted to characterize the optical and acoustic performances of the elements within the center region of the SMOUT array. Two-dimensional and three-dimensional PACT (photoacoustic computed tomography) is also performed to evaluate the imaging performance of the ORW-tuned SMOUT array. The results show that the ORW tuning does not degrade the optical, acoustic, and overall imaging performances of the SMOUT elements. As a result, the fine-tuning method enables new SMOUT-based PACT systems that are low cost, compact, powerful, and even higher speed, with parallel readout capability.
more »
« less
- PAR ID:
- 10544759
- Publisher / Repository:
- MDPI
- Date Published:
- Journal Name:
- Micromachines
- Volume:
- 15
- Issue:
- 9
- ISSN:
- 2072-666X
- Page Range / eLocation ID:
- 1111
- Format(s):
- Medium: X
- Sponsoring Org:
- National Science Foundation
More Like this
-
-
This Letter reports the integration of microlenses (MLs) on a surface-micromachined optical ultrasound transducer (SMOUT) array to enable parallel ultrasound data readout from a multiplicity of elements. The MLs are fabricated by photoresist patterning and reflow, and their focal lengths are optimized with parametric studies. Experiments are conducted to characterize the acoustic responsivity and its uniformity of the SMOUT-ML elements under different conditions. The temporal stability of SMOUT-ML elements immersed in water is assessed by monitoring their acoustic response continuously for 1 week. Parallel ultrasound signal readout is simulated with a small group of SMOUT-ML elements. Experimental results show that high acoustic sensitivity and excellent long-term stability can be achieved by the ML-integrated SMOUT array, which could provide a promising approach for enabling parallel ultrasound data acquisition for improving the imaging speed of 3D acoustic tomography.more » « less
-
Linear transducer arrays are widely used in photoacoustic computed tomography (PACT) due to their lightweight design, cost-effectiveness, and handheld convenience. Despite these advantages, the inherent focusing design of the linear array results in anisotropic resolution in 3D. Specifically, the elevational resolution is approximately an order of magnitude worse than both lateral and axial resolutions. In this work, we propose multiview linear PACT (MvLPACT) to overcome this limitation. By combining the scanned data along the elevational direction from multiple angles, MvLPACT compensates for the deficiencies in elevational resolution. A multiview fast iterative shrinkage-thresholding algorithm (FISTA) based deconvolution, named MvFISTA-Deconv, is applied to the multiview scanning data to reconstruct 3D images. MvFISTA-Deconv integrates the high-frequency components that correspond to high-resolution features acquired from multiple angles into the reconstructed 3D images with improved resolution. Our proposed MvLPACT is evaluated on both phantoms and in vivo human experiments, showing a significant elevational resolution improvement up to 8-fold. Our results demonstrate MvLPACT as a powerful and robust technique for high-resolution 3D imaging in PACT applications, offering substantial advancements over traditional linear-array-based PACT.more » « less
-
Photoacoustic imaging (PAI) is a hybrid image modality that combines optical absorption contrast and acoustic detection of light-induced ultrasound waves. PAI can produce high-resolution and molecular-sensitive images of deep tissues, which are useful for various preclinical studies, such as brain functions, cancer therapy, and vascular imaging. However, PAI faces the challenge of strong optical attenuation in biological tissues, which limits the imaging depth of conventional PAI to several centimeters. Many clinically relevant organs are located near body cavities, which offers the opportunity to navigate a catheter-based device for internal-illumination PAI. By delivering light directly to the target through an optical fiber, internal-illumination PAI can effectively overcome the optical attenuation problem and achieve imaging depths of more than 10 cm while maintaining the resolution, signal-to-noise ratio, and functional and molecular sensitivity of PAI. Thus, internal-illumination PAI has great potential for medical applications. This review introduces the principles and applications of different internal-illumination PAI modalities: photoacoustic endoscopy, internal-illumination photoacoustic tomography, and photoacoustic-guided ablation. We highlight the current research directions and challenges and discuss the future opportunities.more » « less
-
Nanoparticle-mediated photothermal therapy (PTT) is a promising strategy for cancer treatment; however, nanoparticle instability and lack of precise imaging tools for real-time temperature monitoring during therapy and nanoparticle tracking have hindered investigations in animal models. To address these critical issues, we present a theranostic platform that seamlessly integrates armored core–gold nanostar (AC-GNS)–mediated PTT with full-view photoacoustic computed tomography (PACT), enabling nanoparticle tracking and real-time imaging-guided PTT in deep tissues. The AC-GNS platform delivered exceptional photostability and thermal resilience beyond those of conventional nanoparticles while serving as a high-performance contrast agent for PACT and a photothermal transducer for PTT. Integrating AC-GNS–mediated PTT with noninvasive PACT enabled whole-body nanoparticle tracking, PTT treatment monitoring via thermal imaging, and thermal dose determination, culminating in a 100% survival rate in a murine bladder cancer model without long-term treatment-related toxicity. This theranostic platform lays the foundation for broader research applications and provides opportunities for advancing solid tumor treatment and response assessment research.more » « less
An official website of the United States government