Title: A cavity ion source for high-ionization efficiency neodymium isotope-ratio analyses in the geosciences
The principles governing ionization techniques used in thermal ionization mass spectrometers are relatively well understood and have remained largely unchanged for many decades. Though significant advances have been made in ion signal quantification for isotope ratio measurements, particularly for analyses of small samples by using multiple detector systems and low-noise amplifiers, the fundamental approach to sample ionization has received little focus. Modern TIMS techniques attempting to achieve parts-per-million level isotope ratios precisions are realizing limits imposed by the physics of the ionization source. A type of high-ionization efficiency thermal source employed in nuclear physics communities for decades is the so-called cavity thermal ionization source. Here, we provide a proof-of-concept study that shows cavity sources may provide a path forward to achieve a new level of precision in isotope ratio measurements from solid samples. We document our new, simple, cavity ion source design, show preliminary results from Nd isotope measurements, and discuss these new data in the context of current precision limits imposed during traditional thermal ionization methods. We show that, within the limits of our testbed mass spectrometer, mass fractionation within the cavity ion source appears similar to that from filament ion sources. We also demonstrate that oxide- versus -metal ion production plays a significant role in cavity ionization processes for Nd. Cavity ion sources may provide a viable path forward to achieving isotope ratios precisions at the sub-ppm precision level.  more » « less
Award ID(s):
2017252
PAR ID:
10401636
Author(s) / Creator(s):
; ;
Date Published:
Journal Name:
Journal of Analytical Atomic Spectrometry
Volume:
35
Issue:
10
ISSN:
0267-9477
Page Range / eLocation ID:
2337 to 2350
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. None (Ed.)
    The common assumption that residual peridotites retain the Nd-Hf isotope ratios in the mantle source is debated because melt and solid of different isotopic compositions could undergo chemical exchange during melt migration, altering the isotopic signature of the source. By modeling the transport of chemical heterogeneities in the melting region beneath a mid-ocean ridge, we show that the shape of a chemical heterogeneity marked by Nd or Hf isotope ratio changes systematically through subvertical dispersion, stretching, compression, and shearing. The isotope ratios inside the chemical heterogeneity decay toward the values of background mantle. The amount of decay depends on the strength of dispersion, which itself is strongly dependent on the melt fraction in the melting region. When the maximum melt fraction is greater than 1%, buoyancy-driven melt flow relative to the solid causes subvertical dispersion of isotopic signals in the solid. Differential flows of the melt and solid also produce chromatography fractionation of Nd with respect to Hf, causing their isotope ratios to decouple. Compositions of the residue in Nd-Hf isotope ratio diagram do not record the endmembers in the source, instead they represent an area that covers part of the binary mixing line between the background mantle and the original heterogeneity. In the case of small melt fraction (<0.2%), the low permeability results in sluggish melt flow, weak dispersion, and negligible chromatography fractionation. Consequently, Nd and Hf isotope ratios in the residue remain coupled, representing the endmember isotope ratios in the source. The ridge model with larger melt fraction may correspond to the fast-spreading ridge, while the model with smaller melt fraction may correspond to the ultraslow-spreading ridge. The present study underscores the importance of melt migration processes beneath mid-ocean ridges on the deformation, mixing and decoupling of Nd-Hf isotope ratios in residual peridotites. 
    more » « less
  2. Secondary ion mass spectrometry techniques are used to study trace elements in organic samples where matrix compositions vary spatially. This study was conducted to develop calibrations for lithium content and lithium isotope measurements in kerogen. Known concentrations of Li ions (6Li and 7Li) were implanted into organic polymers, with a range of H/C and O/C ratios similar to kerogen, along with glassy carbon (SPI Glas‐22) and silicate glass (NIST SRM 612). Results show that Li content calibration factors (K*) are similar for carbonaceous samples when analysed using a 5kV secondary ion accelerating voltage. Using a 9 kV secondary ion accelerating voltage, K* factors are negatively correlated with the sample O content, changing ~ 30% between 0 and 15 oxygen atomic %. Thus, to avoid the matrix effect related to O content, using a 5 kV secondary ion accelerating voltage is best for quantification of Li contents based on 7Li+/12C+ ratios. Under these analytical conditions, Li ppm (atomic) = (132 (  8) × 7Li+/12C+) × 12C atom fraction of the sample measured. Lithium isotope ratio measurements of SPI Glas‐22 and NIST SRM 612 are within uncertainty; however, the organic polymer samples as a group show a 10‰ higher δ7Li than NIST SRM 612. 
    more » « less
  3. Precise and accurate atomic mass data provide crucial information for applications in a wide range of fields in physics and beyond, including astrophysics, nuclear structure, particle and neutrino physics, fundamental symmetries, chemistry, and metrology. The most precise atomic mass measurements are performed on charged particles confined in a Penning trap. Here, we describe the development, status, and outlook of CHIP-TRAP: the Central Michigan University high-precision Penning trap. CHIP-TRAP aims to perform ultra-high precision (∼1 part in 1011 fractional precision) mass measurements on stable and long-lived isotopes produced with external ion sources and transported to the Penning traps. Along the way, ions of a particular m/q are selected with a multi-reflection time-of-flight mass separator (MR-TOF-MS), with further filtering performed in a cylindrical capture trap before the ions are transported to a pair of hyperbolic measurement traps. In this paper, we report on the design and status of CHIP-TRAP and present results from the commissioning of the ion sources, MR-TOF-MS, and capture trap. We also provide an outlook on the continued development and commissioning of CHIP-TRAP. 
    more » « less
  4. Abstract The minor and trace element compositions of biogenic carbonates such as foraminifera are important tools in paleoceanography research. However, most studies have focused primarily on samples with element to calcium (El/Ca) ratios higher than the El/Ca range often found in benthic foraminifera. Here, we systematically assess the precision and accuracy of foraminifera elemental analysis across a wide range of El/Ca especially at relatively low ratios, using a method on a Thermo Scientific iCAP Qc quadrupole Inductively Coupled Plasma Mass Spectrometer (ICP‐MS). We focus on two benthic foraminifera species,Hoeglundina elegansandCibicidoides pachyderma, and prepared a suite of solution standards based on their typical El/Ca ranges to correct for signal drift and matrix effects during ICP‐MS analysis and to determine analytical precision. We observe comparable precisions with published studies at high El/Ca, and higher relative standard deviations for each element at lower El/Ca, as expected from counting statistics. The overall long‐term analytical precision (2σ) of theH. elegans‐like consistency standard solutions was 6.5%, 4.6%, 5.0%, for Li/Ca, Mg/Ca, Mg/Li, and 6.4%, 10.0%, 4.2% for B/Ca, Cd/Ca, Sr/Ca. The precision forH. elegans‐like Mg/Li is equivalent to a temperature uncertainty of 0.5–1.1°C. Measurement precisions were also assessed based on three international standards (one solution and two powder standards) and replicate measurements ofH. elegansandC. pachydermasamples. We provide file templates and program scripts that can be used to design calibration and consistency standards, prepare run sequences, and convert the raw ICP‐MS data into molar ratios. 
    more » « less
  5. Secondary ion mass spectrometry techniques are used to study trace elements in organic samples where matrix compositions vary spatially. This study was conducted to develop calibrations for lithium content and lithium isotope measurements in kerogen. Known concentrations of Li ions (6Li and7Li) were implanted into organic polymers, with a range of H/C and O/C ratios similar to kerogen, along with glassy carbon (SPI Glas‐22) and silicate glass (NIST SRM 612). Results show that Li content calibration factors (K*) are similar for carbonaceous samples when analysed using a 5 kV secondary ion accelerating voltage. Using a 9 kV secondary ion accelerating voltage,K* factors are negatively correlated with the sample O content, changing ~ 30% between 0 and 15 oxygen atomic %. Thus, to avoid the matrix effect related to O content, using a 5 kV secondary ion accelerating voltage is best for quantification of Li contents based on7Li+/12C+ratios. Under these analytical conditions, Li ppm (atomic) = (132 (± 8) × 7Li+/12C+) × 12C atom fraction of the sample measured. Lithium isotope ratio measurements of SPI Glas‐22 and NIST SRM 612 are within uncertainty; however, the organic polymer samples as a group show a 10‰ higher δ7Li than NIST SRM 612. 
    more » « less