Title: A model of fluid–structure and biochemical interactions for applications to subclinical leaflet thrombosis
Abstract Subclinical leaflet thrombosis (SLT) is a potentially serious complication of aortic valve replacement with a bioprosthetic valve in which blood clots form on the replacement valve. SLT is associated with increased risk of transient ischemic attacks and strokes and can progress to clinical leaflet thrombosis. SLT following aortic valve replacement also may be related to subsequent structural valve deterioration, which can impair the durability of the valve replacement. Because of the difficulty in clinical imaging of SLT, models are needed to determine the mechanisms of SLT and could eventually predict which patients will develop SLT. To this end, we develop methods to simulate leaflet thrombosis that combine fluid–structure interaction and a simplified thrombosis model that allows for deposition along the moving leaflets. Additionally, this model can be adapted to model deposition or absorption along other moving boundaries. We present convergence results and quantify the model's ability to realize changes in valve opening and pressures. These new approaches are an important advancement in our tools for modeling thrombosis because they incorporate both adhesion to the surface of the moving leaflets and feedback to the fluid–structure interaction.  more » « less
Award ID(s):
1652541 1931516
PAR ID:
10413014
Author(s) / Creator(s):
 ;  ;  ;  ;  ;  ;  ;  
Publisher / Repository:
Wiley Blackwell (John Wiley & Sons)
Date Published:
Journal Name:
International Journal for Numerical Methods in Biomedical Engineering
Volume:
39
Issue:
5
ISSN:
2040-7939
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. Abstract Transcatheter aortic valve replacement (TAVR) first received FDA approval for high-risk surgical patients in 2011 and has been approved for low-risk surgical patients since 2019. It is now the most common type of aortic valve replacement, and its use continues to accelerate. Computer modeling and simulation (CM&S) is a tool to aid in TAVR device design, regulatory approval, and indication in patient-specific care. This study introduces a computational fluid-structure interaction (FSI) model of TAVR with Medtronic’s CoreValve Evolut R device using the immersed finite element-difference (IFED) method. We perform dynamic simulations of crimping and deployment of the Evolut R, as well as device behavior across the cardiac cycle in a patient-specific aortic root anatomy reconstructed from computed tomography (CT) image data. These IFED simulations, which incorporate biomechanics models fit to experimental tensile test data, automatically capture the contact within the device and between the self-expanding stent and native anatomy. Further, we apply realistic driving and loading conditions based on clinical measurements of human ventricular and aortic pressures and flow rates to demonstrate that our Evolut R model supports a physiological diastolic pressure load and provides informative clinical performance predictions. 
    more » « less
  2. Calcific aortic valve disease (CAVD) is an active pathobiological process leading to severe aortic stenosis, where the only treatment is valve replacement. Late-stage CAVD is characterized by calcification, disorganization of collagen, and deposition of glycosaminoglycans, such as chondroitin sulfate (CS), in the fibrosa. We developed a three-dimensional microfluidic device of the aortic valve fibrosa to study the effects of shear stress (1 or 20 dyne per cm 2 ), CS (1 or 20 mg mL −1 ), and endothelial cell presence on calcification. CAVD chips consisted of a collagen I hydrogel, where porcine aortic valve interstitial cells were embedded within and porcine aortic valve endothelial cells were seeded on top of the matrix for up to 21 days. Here, we show that this CAVD-on-a-chip is the first to develop human-like calcified nodules varying in calcium phosphate mineralization maturity resulting from high shear and endothelial cells, specifically di- and octa-calcium phosphates. Long-term co-culture microfluidic studies confirmed cell viability and calcium phosphate formations throughout 21 days. Given that CAVD has no targeted therapies, the creation of a physiologically relevant test-bed of the aortic valve could lead to advances in preclinical studies. 
    more » « less
  3. Computational cardiovascular flow analysis can provide valuable information to medical doctors in a wide range of patientspecific cases, including cerebral aneurysms, aortas and heart valves. The computational challenges faced in this class of flow analyses also have a wide range. They include unsteady flows, complex cardiovascular geometries, moving boundaries and interfaces, such as the motion of the heart valve leaflets, contact between moving solid surfaces, such as the contact between the leaflets, and the fluid–structure interaction between the blood and the cardiovascular structure. Many of these challenges have been or are being addressed by the Space–Time Variational Multiscale (ST-VMS) method, Arbitrary Lagrangian–Eulerian VMS (ALE-VMS) method, and the VMS-based Immersogeometric Analysis (IMGA-VMS), which serve as the core computational methods, and the special methods used in combination with them. We provide an overview of the core and special methods and present examples of challenging computations carried out with these methods, including aorta and heart valve flow analyses. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium provided the original work is properly cited. 
    more » « less
  4. Introduction: Calcific aortic valve disease (CAVD) is an active pathological process leading to severe valve calcification. Late-stage CAVD is characterized by increased leaflet stiffness, disorganized collagen bundles and the deposition of glycosaminoglycans, such as chondroitin sulfate (CS), in the fibrosa layer. However, many details of the cellular pathological cascade remain unknown. Animal models such as mice, rabbits, and pigs are used in understanding human CAVD, but mice do not have similar anatomy, rabbits cannot spontaneously develop atherosclerotic lesions, and pigs require long, expensive and complex studies. Here we utilize microfluidic devices of the aortic valve fibrosa to model late-stage CAVD. Hypothesis: We assessed the hypothesis that microfluidic calcification will increase with increased shear rates and CS content. Methods: Valve-on-a-chip devices contained a hydrogel of 1.5 mg/mL collagen I-only healthy controls or 1.5 mg/mL collagen I with 1 mg/mL or 20 mg/mL CS. Porcine aortic valve interstitial cells (PAVIC) were embedded within and endothelial cells (PAVEC) were seeded onto the matrix. Steady shear stress at 1 dyne/cm 2 and 20 dyne/cm 2 were applied using a peristaltic pump for 14 days. Alizarin Red S (ARS), an assay to assess calcium deposition, was used to quantify calcific nodule formation. Scanning electron microscopy with energy dispersive x-ray (SEM/EDX) was used to further analyze sample mineralization. Results: Co-cultures in the presence of increasing shear stress and CS exhibit increased calcific nodule formation compared to static controls, both qualitatively and quantitatively (n≥3). SEM revealed the microstructure of calcified nodules and EDX confirmed calcium phosphate mineralization with physiologically-relevant calcium to phosphorous ratios (Ca/P= 0.88 - 1.4). Conclusions: These results show that in vitro calcification is driven by shear stress in the presence of PAVEC and CS. As seen in ex vivo studies of human calcification, these microfluidic-derived nodules are similarly composed of a range of naturally-occurring calcium phosphates. Given that CAVD has no targeted therapy, the creation of a physiologically relevant model of the aortic valve can provide a test bed for novel therapeutic interventions. 
    more » « less
  5. Ghorbel, Mohamed; May-Newman, Karen (Ed.)
    Heart disease is a leading cause of mortality, with calcific aortic valve disease (CAVD) being the most prevalent subset. Being able to predict this disease in its early stages is important for monitoring patients before they need aortic valve replacement surgery. Thus, this study explored hydrodynamic, mechanical, and hemodynamic differences in healthy and very mildly calcified porcine small intestinal submucosa (PSIS) bioscaffold valves to determine any notable parameters between groups that could, possibly, be used for disease tracking purposes. Three valve groups were tested: raw PSIS as a control and two calcified groups that were seeded with human valvular interstitial and endothelial cells (VICs/VECs) and cultivated in calcifying media. These two calcified groups were cultured in either static or bioreactor-induced oscillatory flow conditions. Hydrodynamic assessments showed metrics were below thresholds associated for even mild calcification. Young’s modulus, however, was significantly higher in calcified valves when compared to raw PSIS, indicating the morphological changes to the tissue structure. Fluid–structure interaction (FSI) simulations agreed well with hydrodynamic results and, most notably, showed a significant increase in time-averaged wall shear stress (TAWSS) between raw and calcified groups. We conclude that tracking hemodynamics may be a viable biomarker for early-stage CAVD tracking. 
    more » « less