Several problems challenge mesoscopic imaging in the brain: 1) Difficulty with positioning high-NA objectives near the brain; 2) Creating a flat imaging window against the surface of the brain; 3) Adjusting the imaging window in the face of changes in swelling and pressure in the brain; 4) Preventing growth of dura and biofilms that obscure the imaging window; 5) Follow-on MRI imaging of the animal post-implantation. We propose here an ultra-large window radiolucent implant to address these issues. Our approach provides a 2 cm diameter window for non-human primates (NHPs) that regulates pressure and employs a stable, strong, and thin design. The system is mechanically modeled and stress-tested to achieve access to the brain by large objectives, with design features that allow for manual repositioning of the imaging lens. To optimize the distance between the objective and the brain, we prioritize a thin implant design. A strong radiolucent implant is created using PEEK plastic, a strong, thermoresistant and biostable material. We heighten strength of the chamber’s attachment to the skull by using titanium screws that are normal to the surface of the bone at each point. The implant design has several parts and contemplates a potential method to maintain pressure on the brain. This method uses an engineered silicone mount to maintain even pressure of the imaging window on the brain’s surface, despite brain motion. The mechanical properties of the silicone are manipulated to closely resemble that of brain tissue to be more biomimetic and act as a cushion for motion. This method also allows for the manual repositioning of the cover slip to create a flat imaging window. Lastly, our approach prevents dural growth by blocking the migration of migratory biofilm-forming cells; we hypothesize that use of dynamic pressure maintenance on the brain is key to this method’s success. We are also investigating methods to elongate the longevity of the implant and imaging site, such as silver sputtering on implants and blue light therapy. These methods have produced an ultra-large field of view with 2P image results in <60,000 neurons. As such the chambers are expected to enhance recording window longevity and may prove to be a critical advance in NHP and human brain imaging.
more »
« less
A Novel pressure regulating brain imaging implant for ultra large field of view microscopic imaging in primates
Several problems challenge mesoscopic imaging in the brain: 1) Difficulty with positioning high-NA objectives near the brain; 2) Creating a flat imaging window against the surface of the brain; 3) Adjusting the imaging window in the face of changes in swelling and pressure in the brain; 4) Preventing growth of dura and biofilms that obscure the imaging window; 5) Follow-on MRI imaging of the animal post-implantation. We propose here an ultra-large window radiolucent implant to address these issues. Our approach provides a 2 cm diameter window for non-human primates (NHPs) that regulates pressure and employs a stable, strong, and thin design. The system is mechanically modeled and stress-tested to achieve access to the brain by large objectives, with design features that allow for manual repositioning of the imaging lens. To optimize the distance between the objective and the brain, we prioritize a thin implant design. A strong radiolucent implant is created using PEEK plastic, a strong, thermoresistant and biostable material. We heighten strength of the chamber’s attachment to the skull by using titanium screws that are normal to the surface of the bone at each point. The implant design has several parts and contemplates a potential method to maintain pressure on the brain. This method uses an engineered silicone mount to maintain even pressure of the imaging window on the brain’s surface, despite brain motion. The mechanical properties of the silicone are manipulated to closely resemble that of brain tissue to be more biomimetic and act as a cushion for motion. This method also allows for themanual repositioning of the cover slip to create a flat imaging window. Lastly, our approach prevents dural growth by blocking the migration of migratory biofilm-forming cells; we hypothesize that use of dynamic pressure maintenance on the brain is key to this method’s success. We are also investigating methods to elongate the longevity of the implant and imaging site, such as silver sputtering on implants and blue light therapy. These methods have produced an ultra-large field of view with 2P image results in <60,000 neurons. As such the chambers are expected to enhance recording window longevity and may prove to be a critical advance in NHP and human brain imaging.
more »
« less
- Award ID(s):
- 1734887
- PAR ID:
- 10430745
- Date Published:
- Journal Name:
- Society for Neuroscience 2021
- Format(s):
- Medium: X
- Sponsoring Org:
- National Science Foundation
More Like this
-
-
Abstract Some textured silicone breast implants with high average surface roughness (‘macrotextured’) have been associated with a rare cancer of the immune system, Breast Implant-Associated Anaplastic Large Cell Lymphoma (BIA-ALCL). Silicone elastomer wear debris may lead to chronic inflammation, a key step in the development of this cancer. Here, we model the generation and release of silicone wear debris in the case of a folded implant-implant (‘shell-shell’) sliding interface for three different types of implants, characterized by their surface roughness. The ‘smooth’ implant shell with the lowest average surface roughness tested (R a = 2.7 ± 0.6 μ m) resulted in average friction coefficients of μ avg = 0.46 ± 0.11 across 1,000 mm of sliding distance and generated 1,304 particles with an average particle diameter of D avg = 8.3 ± 13.1 μ m. The ‘microtextured’ implant shell (R a = 32 ± 7.0 μ m) exhibited μ avg = 1.20 ± 0.10 and generated 2,730 particles with D avg = 4.7 ± 9.1 μ m. The ‘macrotextured’ implant shell (R a = 80 ± 10 μ m) exhibited the highest friction coefficients, μ avg = 2.82 ± 0.15 and the greatest number of wear debris particles, 11,699, with an average particle size of D avg = 5.3 ± 3.3 μ m. Our data may provide guidance for the design of silicone breast implants with lower surface roughness, lower friction, and smaller quantities of wear debris.more » « less
-
Silicone elastomer medical implants are ubiquitous in medicine, particularly for breast augmentation. However, when these devices are placed within the body, disruption of the natural biological interfaces occurs, which significantly changes the native energy-dissipation mechanisms of living systems. These new interfaces can introduce non-physiological contact pressures and tribological conditions that provoke inflammation and soft tissue damage. Despite their significance, the biotribological properties of implant-tissue and implant-extracellular matrix (ECM) interfaces remain poorly understood. Here, we developed an in vitro model of soft tissue damage using a custom-built in situ biotribometer mounted onto a confocal microscope. Sections of commercially-available silicone breast implants with distinct and clinically relevant surface roughness ([Formula: see text]m, [Formula: see text]m, and [Formula: see text]m) were mounted to spherically-capped hydrogel probes and slid against collagen-coated hydrogel surfaces as well as healthy breast epithelial (MCF10A) cell monolayers to model implant-ECM and implant-tissue interfaces. In contrast to the “smooth” silicone implants ([Formula: see text]m), we demonstrate that the “microtextured” silicone implant ([Formula: see text]m) induced higher frictional shear stress ([Formula: see text] Pa), which led to greater collagen removal and cell rupture/delamination. Our studies may provide insights into post-implantation tribological interactions between silicone breast implants and soft tissues.more » « less
-
Abstract: Thin tissue slice based histology has been used as a gold standard for disease diagnosis since over a hundred years ago. However, histopathological evaluation on two-dimensional slides suffers from large variations due to limited sampling. To improve the diagnostic accuracy, three-dimensional (3D) histology is performed through serial sectioning, staining, imaging and reconstruction of individual slices, which is highly time-consuming and labor intensive. We developed a volumetric stimulated Raman scattering (SRS) imaging method, which provides histology-like information in 3D context without the need for staining with dyes. Using a small molecule clearing agent, formamide, we performed tissue clearing within 30 min and achieved an imaging depth up to 500 µm in highly scattered tissues, including brain, kidney, liver and lung. Through a two-color SRS imaging scheme, we obtained histology-like images in cleared brain tissue slices. Our method has the potential for 3D tissue histopathology to improve the accuracy of histopathological examination. https://doi.org/10.1364/BOE.10.004329more » « less
-
ABSTRACT IntroductionThe cervical spine, pivotal for mobility and overall body function, can be affected by cervical spondylosis, a major contributor to neural disorders. Prevalent in both general and military populations, especially among pilots, cervical spondylosis induces pain and limits spinal capabilities. Anterior Cervical Discectomy and Fusion (ACDF) surgery, proposed by Cloward in the 1950s, is a promising solution for restoring natural cervical curvature. The study objective was to investigate the impacts of ACDF implant design on postsurgical cervical biomechanics and neurorehabilitation outcomes by utilizing a biofield head-neck finite element (FE) platform that can facilitate scenario-specific perturbations of neck muscle activations. This study addresses the critical need to enhance computational models, specifically FE modeling, for ACDF implant design. Materials and MethodsWe utilized a validated head-neck FE model to investigate spine–implant biomechanical interactions. An S-shaped dynamic cage incorporating titanium (Ti) and polyetheretherketone (PEEK) materials was modeled at the C4/C5 level. The loading conditions were carefully designed to mimic helmet-to-helmet impact in American football, providing a realistic and challenging scenario. The analysis included intervertebral joint motion, disk pressure, and implant von Mises stress. ResultsThe PEEK implant demonstrated an increased motion in flexion and lateral bending at the contiguous spinal (C4/C5) level. In flexion, the Ti implant showed a modest 5% difference under 0% activation conditions, while PEEK exhibited a more substantial 14% difference. In bending, PEEK showed a 24% difference under 0% activation conditions, contrasting with Ti’s 17%. The inclusion of the head resulted in an average increase of 18% in neck angle and 14% in C4/C5 angle. Disk pressure was influenced by implant material, muscle activation level, and the presence of the head. Polyetheretherketone exhibited lower stress values at all intervertebral disc levels, with a significant effect at the C6/C7 levels. Muscle activation level significantly influenced disk stress at all levels, with higher activation yielding higher stress. Titanium implant consistently showed higher disk stress values than PEEK, with an orders-of-magnitude difference in von Mises stress. Excluding the head significantly affected disk and implant stress, emphasizing its importance in accurate implant performance simulation. ConclusionsThis study emphasized the use of a biofidelic head-neck model to assess ACDF implant designs. Our results indicated that including neck muscles and head structures improves biomechanical outcome measures. Furthermore, unlike Ti implants, our findings showed that PEEK implants maintain neck motion at the affected level and reduce disk stresses. Practitioners can use this information to enhance postsurgery outcomes and reduce the likelihood of secondary surgeries. Therefore, this study makes an important contribution to computational biomechanics and implant design domains by advancing computational modeling and theoretical knowledge on ACDF–spine interaction dynamics.more » « less