Despite substantial research efforts in developing high-voltage sodium-ion batteries (SIBs) as high-energy-density alternatives to complement lithium-ion-based energy storage technologies, the lifetime of high-voltage SIBs is still associated with many fundamental scientific questions. In particular, the structure phase transition, oxygen loss, and cathode–electrolyte interphase (CEI) decay are intensely discussed in the field. Synchrotron X-ray and neutron scattering characterization techniques offer unique capabilities for investigating the complex structure and dynamics of high-voltage cathode behavior. In this review, to accelerate the development of stable high-voltage SIBs, we provide a comprehensive and thorough overview of the use of synchrotron X-ray and neutron scattering in studying SIB cathode materials with an emphasis on high-voltage layered transition metal oxide cathodes. We then discuss these characterizations in relation to polyanion-type cathodes, Prussian blue analogues, and organic cathode materials. Finally, future directions of these techniques in high-voltage SIB research are proposed, including CEI studies for polyanion-type cathodes and the extension of neutron scattering techniques, as well as the integration of morphology and phase characterizations.
more »
« less
Synchrotron science for sustainability: life cycle of metals in the environment
Abstract The movement of metals through the environment links together a wide range of scientific fields: from earth sciences and geology as weathering releases minerals; to environmental sciences as metals are mobilized and transformed, cycling through soil and water; to biology as living things take up metals from their surroundings. Studies of these fundamental processes all require quantitative analysis of metal concentrations, locations, and chemical states. Synchrotron X-ray tools can address these requirements with high sensitivity, high spatial resolution, and minimal sample preparation. This perspective describes the state of fundamental scientific questions in the lifecycle of metals, from rocks to ecosystems, from soils to plants, and from environment to animals. Key X-ray capabilities and facility infrastructure for future synchrotron-based analytical resources serving these areas are summarized, and potential opportunities for future experiments are explored.
more »
« less
- Award ID(s):
- 1656321
- PAR ID:
- 10443978
- Publisher / Repository:
- Oxford University Press
- Date Published:
- Journal Name:
- Metallomics
- Volume:
- 15
- Issue:
- 8
- ISSN:
- 1756-591X
- Format(s):
- Medium: X
- Sponsoring Org:
- National Science Foundation
More Like this
-
-
Abstract X‐ray microscopy can provide unique chemical, electronic, and structural insights into perovskite materials and devices leveraging bright, tunable synchrotron X‐ray sources. Over the last decade, fundamental understanding of halide perovskites and their impressive performance in optoelectronic devices has been furthered by rigorous research regarding their structural and chemical properties. Herein, studies of perovskites are reviewed that have used X‐ray imaging, spectroscopy, and scattering microscopies that have proven valuable tools toward understanding the role of defects, impurities, and processing on perovskite material properties and device performance. Together these microscopic investigations have augmented the understanding of the internal workings of perovskites and have helped to steer the perovskite community toward promising directions. In many ways, X‐ray microscopy of perovskites is still in its infancy, which leaves many exciting paths unexplored including new ptychographic, multimodal, in situ, and operando experiments. To explore possibilities, pioneering X‐ray microscopy along these lines is briefly highlighted from other semiconductor systems including silicon, CdTe, GaAs, CuInxGa1−xSe2, and organic photovoltaics. An overview is provided on the progress made in utilizing X‐ray microscopy for perovskites and present opportunities and challenges for future work.more » « less
-
ABSTRACT Over ∼150 resolved, kpc-scale X-ray jets hosted by active galactic nuclei have been discovered with the Chandra X-ray Observatory. A significant fraction of these jets have an X-ray spectrum either too high in flux or too hard to be consistent with the high-energy extension of the radio-to-optical synchrotron spectrum, a subtype we identify as Multiple Spectral Component (MSC) X-ray jets. A leading hypothesis for the origin of the X-rays is the inverse-Compton scattering of the cosmic microwave background by the same electron population producing the radio-to-optical synchrotron spectrum (known as the IC/CMB model). In this work, we test the IC/CMB model in 45 extragalactic X-ray jets using observations from the Fermi Large Area Telescope to look for the expected high level of gamma-ray emission, utilizing observations from the Atacama Large Millimeter/submillimeter Array (ALMA) and the Hubble Space Telescope (HST) when possible to best constrain the predicted gamma-ray flux. Including this and previous works, we now find the IC/CMB model to be ruled out in a total of 24/45 MSC X-ray jets due to its over-prediction for the observed MeV-to-GeV gamma-ray flux. We present additional evidence against the IC/CMB model, including the relative X-ray-to-radio relativistic beaming in these sources, and the general mismatch between radio and X-ray spectral indexes. Finally, we present upper limits on the large-scale bulk-flow Lorentz factors for all jets based on the Fermi upper limits, which suggest that these jets are at most mildly relativistic.more » « less
-
ABSTRACT Sgr A* exhibits flares in the near-infrared and X-ray bands, with the luminosity in these bands increasing by factors of 10–100 for ≈60 min. One of the models proposed to explain these flares is synchrotron emission of non-thermal particles accelerated by magnetic reconnection events in the accretion flow. We use the results from particle-in-cell simulations of magnetic reconnection to post-process 3D two-temperature GRMHD simulations of a magnetically arrested disc (MAD). We identify current sheets, retrieve their properties, estimate their potential to accelerate non-thermal particles, and compute the expected non-thermal synchrotron emission. We find that the flux eruptions of MADs can provide suitable conditions for accelerating non-thermal particles to energies γe ≲ 106 and producing simultaneous X-ray and near-infrared flares. For a suitable choice of current-sheet parameters and a simplified synchrotron cooling prescription, the model can simultaneously reproduce the quiescent and flaring X-ray luminosities as well as the X-ray spectral shape. While the near-infrared flares are mainly due to an increase in the temperature near the black hole during the MAD flux eruptions, the X-ray emission comes from narrow current sheets bordering highly magnetized, low-density regions near the black hole, and equatorial current sheets where the flux on the black hole reconnects. As a result, not all infrared flares are accompanied by X-ray ones. The non-thermal flaring emission can extend to very hard (≲ 100 keV) X-ray energies.more » « less
-
Tracking the change in electronic structure of target elements is crucial to investigate the nature of redox reactions occurring in battery electrodes. X-ray emission spectroscopy (XES) and x-ray absorption fine structure (XAFS) perform this role well with high sensitivity and throughput, but the requisite of synchrotron facilities often limits those availability for material characterization. Using a lab-scale x-ray emission/absorption spectrometer, we investigated the changes in the local structure and chemistry around the 3d transition metal elements of LiMO 2 cathodes for Li-ion batteries as a function of the battery state of charge (SoC). Ex situ measurement was prepared from the electrode samples with discrete difference in SoC. Coupled with ex situ measurement, operando measurement was performed using pouch cells with LiMO 2 cathode, which enabled a real-time monitoring of chemical shift in an element-specific manner resulted from changing electrode potential. Through the XES mode of the bench-top spectrometer, fluorescence emissions from the LiMO 2 cathode, or the cell containing it, was monochromatized by a spherically bent crystal analyzer (SBCA). The Kβ emissions of 3d transition metal elements such as cobalt display position/shape difference of spectrum with varying SoC. The trend of chemical shift and change in spectral features provided the information on the electronic structure variation, such as oxidation state change of 3d transition metals in LiMO 2 during charge and discharge (i.e., delithiation and lithiation). Furthermore, valence-to-core (VtC) emission signals helped enable in-depth analysis such as spin structure characterization. In addition to the XES analysis, we could measure K-edge XAFS for the same 3d transition metals in LiMO 2 as well. In the XAFS mode of the spectrometer, SBCA monochromatized bremsstrahlung x-ray generated from a high-power x-ray tube is used to make an incident source energy-dispersive. While Kβ XES probed occupied levels, K-edge XAFS examined unoccupied levels providing comprehensive understanding on the change in electronic structure of 3d transition metals in LiMO 2 . Figure 1more » « less