Title: Influence of testing environment and loading rate on intervertebral disc compressive mechanics: An assessment of repeatability at three different laboratories
Abstract In vitro mechanical testing of intervertebral discs is crucial for basic science and pre‐clinical testing. Generally, these tests aim to replicate in vivo conditions, but simplifications are necessary in specimen preparation and mechanical testing due to complexities in both structure and the loading conditions required to replicate in vivo conditions. There has been a growing interest in developing a consensus of testing protocols within the spine community to improve comparison of results between studies. The objective of this study was to perform axial compression experiments on bovine bone‐disc‐bone specimens at three institutions. No differences were observed between testing environment being air, with PBS soaked gauze, or a PBS bath (P > .206). A 100‐fold increase in loading rate resulted in a small (2%) but significant increase in compressive mechanics (P < .017). A 7% difference in compressive stiffness between Labs B and C was eliminated when values were adjusted for test system compliance. Specimens tested at Lab A, however, were found to be stiffer than specimens from Lab B and C. Even after normalizing for disc geometry and adjusting for system compliance, an ∼35% difference was observed between UK based labs (B and C) and the USA based lab (A). Large differences in specimen stiffness may be due to genetic differences between breeds or in agricultural feed and use of growth hormones; highlighting significant challenges in comparing mechanics data across studies. This research provides a standardized test protocol for the comparison of spinal specimens and provides steps towards understanding how location and test set‐up may affect biomechanical results.  more » « less
Award ID(s):
1751212
PAR ID:
10456431
Author(s) / Creator(s):
 ;  ;  ;  ;  ;  
Publisher / Repository:
Wiley Blackwell (John Wiley & Sons)
Date Published:
Journal Name:
JOR SPINE
Volume:
3
Issue:
3
ISSN:
2572-1143
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. null (Ed.)
    Abstract Painful herniated discs are treated surgically by removing extruded nucleus pulposus (NP) material (nucleotomy). NP removal through enzymatic digestion is also commonly performed to initiate degenerative changes to study potential biological repair strategies. Experimental and computational studies have shown a decrease in disc stiffness with nucleotomy under single loading modalities, such as compression-only or bending-only loading. However, studies that apply more physiologically relevant loading conditions, such as compression in combination with bending or torsion, have shown contradicting results. We used a previously validated bone–disc–bone finite element model (Control) to create a Nucleotomy model to evaluate the effect of dual loading conditions (compression with torsion or bending) on intradiscal deformations. While disc joint stiffness decreased with nucleotomy under single loading conditions, as commonly reported in the literature, dual loading resulted in an increase in bending stiffness. More specifically, dual loading resulted in a 40% increase in bending stiffness under flexion and extension and a 25% increase in stiffness under lateral bending. The increase in bending stiffness was due to an increase and shift in compressive stress, where peak stresses migrated from the NP–annulus interface to the outer annulus. In contrast, the decrease in torsional stiffness was due to greater fiber reorientation during compression. In general, large radial strains were observed with nucleotomy, suggesting an increased risk for delamination or degenerative remodeling. In conclusion, the effect of nucleotomy on disc mechanics depends on the type and complexity of applied loads. 
    more » « less
  2. This research investigated experimentally the seismic performance of steel gravity framing with a concrete slab at the system level. Two half-story, two-by-three bay steel gravity frame specimens were tested under cyclic loading. Bolted-bolted double-angle connections were used for a beam-to-column gravity connection. Primary design variables and construction details include the orientation of the metal deck to the loading direction, the presence or absence of metal deck seams on secondary beams, and the contribution of additional reinforcement bars in the concrete slab. Concrete blocks were positioned at the midpoint of each bay to simulate gravity loads, and a quasi-static displacement-controlled cyclic loading protocol was applied to the specimen using three hydraulic actuators. These investigations confirmed general observations from previous subassembly testing programs that the composite steel gravity framing system can provide substantial flexural stiffness, strength, and ductility under cyclic loading. Further, the test findings showed that the primary design variables and construction details significantly affected the cyclic behavior of composite gravity connections. Comparing the test results from a multi-bay setup and a subassembly testing setup, the cyclic behavior showed remarkable differences, especially for cases with weak axis decking or strong axis decking with a seam. These large differences are attributed to a significant separation of the girder from the column in the subassembly testing setup, which may not be present in a real building. Virtually all previous cyclic loading tests on gravity connections have been conducted in subassembly test setups. These subassembly tests are therefore the basis for the models that are currently used to include gravity frame connections in the seismic performance assessment of buildings, and these models may be quite inaccurate in some cases. The data generated in this system-level testing program is intended to support efforts to develop improved models of gravity connections subject to seismic loading. 
    more » « less
  3. Poly(lactic-co-glycolic) acid (PLGA) has been widely implemented in tissue engineering and drug delivery systems, stemming from its biocompatibility, controllable biodegradation, non-toxicity, non-immunogenicity, and tunable mechanical properties. PLGA exhibits a broad range of degradation times and modes, which can be finely tuned by adjusting various parameters, namely by altering the ratio of lactide and glycolide units, molecular weight, end group functionality, specimen geometry, processing temperature, and chemistry of the surrounding medium. To tailor the degradation profile, the in vitro profile should closely reflect the in vivo profile; however, the effects of mechanical loading coupled with hydrolysis on PLGA biodegradation are typically overlooked. To this end, this study investigates the combined effects of mechanical loading and hydrolysis at 37ºC on the changes in the chemical and physical properties of PLGA as it degrades with time. We found that after several days of combined loading and hydrolysis at 37ºC PLGA significantly creeps, whereas non-loaded (but hydrolyzed) specimens only slightly elongated after relatively long-term hydrolysis (~60 days). Despite this observation and perhaps counterintuitively, the hydrolyzed non-loaded samples exhibited faster degradation than hydrolyzed loaded samples. Additionally, our studies indicated the presence of bulk erosion in hydrolyzed non-loaded samples and surface erosion in hydrolyzed loaded samples. We also observed (only) physical ageing in control samples (loaded and non-loaded samples that were not immersed in PBS but exposed to 37 °C). Based on these observations, we discuss potential underlying mechanisms for the observed differences in the biodegradation behavior of PLGA specimens with and without mechanical loading. 
    more » « less
  4. null (Ed.)
    Captive specimens in museum collections facilitate study of rare taxa, but the lifestyles, diets, and lifespans of captive animals differ from their wild counterparts. Trabecular bone architecture adapts to in vivo forces, and may reflect interspecific variation in ecology and behavior as well as intraspecific variation between captive and wild specimens. We compared trunk vertebrae bone microstructure in captive and wild xenarthran mammals to test the effects of ecology and captivity. We collected μCT scans of the last six presacral vertebrae in 13 fossorial, terrestrial, and suspensorial xenarthran species (body mass: 120 g to 35 kg). For each vertebra, we measured centrum length; bone volume fraction (BV.TV); trabecular number and mean thickness (Tb.Th); global compactness (GC); cross-sectional area; mean intercept length; star length distribution; and connectivity and connectivity density. Wild specimens have more robust trabeculae, but this varies with species, ecology, and pathology. Wild specimens of fossorial taxa (Dasypus) have more robust trabeculae than captives, but there is no clear difference in bone microstructure between wild and captive specimens of suspensorial taxa (Bradypus, Choloepus), suggesting that locomotor ecology influences the degree to which captivity affects bone microstructure. Captive Tamandua and Myrmecophaga have higher BV.TV, Tb.Th, and GC than their wild counterparts due to captivity-caused bone pathologies. Our results add to the understanding of variation in mammalian bone microstructure, suggest caution when including captive specimens in bone microstructure research, and indicate the need to better replicate the habitats, diets, and behavior of animals in captivity. 
    more » « less
  5. Bennett, M; Wolf, S.; Frank, B. W. (Ed.)
    Computer simulations for physics labs may be combined with hands-on lab equipment to boost student understanding and make labs more accessible. Hybrid labs of HTML5-based computer simulations and hands-on lab equipment for topics in mechanics were investigated in a large, algebra-based, studio physics course for life science students at a private, research-intensive institution. Computer simulations were combined with hands-on equipment and compared to traditional hands-on labs using an A/B testing protocol. Learning outcomes were measured for the specific topic of momentum conservation by comparing student scores on post-lab exercises, related quiz and exam questions, and a subset of questions on the Energy and Momentum Conceptual Survey (EMCS) administered before and after instruction for both groups. We find that students who completed a hands-on lab vs. a hybrid lab showed no difference in performance on momentum assessments. 
    more » « less