Title: Covalently‐Attached, Surface‐Eroding Polymer Coatings on Magnesium Alloys for Corrosion Control and Temporally Varying Support of Cell Adhesion
Abstract

For degradable magnesium (Mg) alloy‐based stents it would be desirable to delay early corrosion to maintain mechanical strength. Similarly, early after stent placement reduced thrombogenicity is an important feature, while chronically, endothelial cell adhesion and vessel integration are desirable. In this study, surface eroding polymers of amino‐grafted poly(1,3‐trimethylene carbonate) (PTMC‐NH2) and PTMC‐NH2combined with sulfobetaine bearing polymer PSB (PTMC‐NHCO‐PSB) are developed, and these polymers are covalently attached onto 6‐phosphonohexanoic acid (PHA)‐coated AZ31 Mg alloy surfaces in sequence. In vitro degradation testing in ovine plasma shows PTMC, PTMC‐NH2, and PTMC‐NHCO‐PSB cast films experience a gradual thickness and mass loss with maintenance of smooth surfaces, confirming surface erosion behavior. The PTMC‐NH2polymer is firmly bound to the PHA‐modified AZ31 surface and demonstrates a resistance to peeling. PTMC, PTMC‐NH2, and PTMC‐NHCO‐PSB coated AZ31 have a lower corrosion rate versus polylactide‐co‐glycolide coated and untreated AZ31. PTMC‐NHCO‐PSB coated AZ31 inhibits platelet deposition and smooth muscle cell adhesion and growth, but after 2‐week immersion in plasma, this surface supports endothelial cell adhesion and growth. These results suggest PTMC‐NHCO‐PSB surface eroding coating offers a means of controlling corrosion while providing a temporally varying bio‐functionality for biodegradable vascular stent applications.

 
more » « less
NSF-PAR ID:
10456879
Author(s) / Creator(s):
 ;  ;  ;  ;  ;  ;  
Publisher / Repository:
Wiley Blackwell (John Wiley & Sons)
Date Published:
Journal Name:
Advanced Materials Interfaces
Volume:
7
Issue:
15
ISSN:
2196-7350
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. Polymeric coatings can provide temporary stability to bioresorbable metallic stents at the initial stage of deployment by alleviating rapid degradation and providing better interaction with surrounding vasculature. To understand this interfacing biocompatibility, this study explored the endothelial-cytocompatibility of polymer-coated magnesium (Mg) alloys under static and dynamic conditions compared to that of non-coated Mg alloy surfaces. Poly (carbonate urethane) urea (PCUU) and poly (lactic-co-glycolic acid) (PLGA) were coated on Mg alloys (WE43, AZ31, ZWEKL, ZWEKC) and 316L stainless steel (316L SS, control sample), which were embedded into a microfluidic device to simulate a vascular environment with dynamic flow. The results from attachment and viability tests showed that more cells were attached on the polymer-coated Mg alloys than on non-coated Mg alloys in both static and dynamic conditions. In particular, the attachment and viability on PCUU-coated surfaces were significantly higher than that of PLGA-coated surfaces of WE43 and ZWEKC in both static and dynamic conditions, and of AZ31 in dynamic conditions (P<0.05). The elementary distribution map showed that there were relatively higher Carbon weight percentages and lower Mg weight percentages on PCUU-coated alloys than PLGA-coated alloys. Various levels of pittings were observed underneath the polymer coatings, and the pittings were more severe on the surface of Mg alloys that corroded rapidly. Polymer coatings are recommended to be applied on Mg alloys with relatively low corrosion rates, or after pre-stabilizing the substrate. PCUU-coating has more selective potential to enhance the biocompatibility and mitigate the endothelium damage of Mg alloy stenting. 
    more » « less
  2. null (Ed.)
    Lack of long-term patency has hindered the clinical use of small-diameter prosthetic vascular grafts with the majority of these failures due to the development of neointimal hyperplasia. Previous studies by our laboratory revealed that small-diameter expanded polytetrafluoroethylene (ePTFE) grafts coated with antioxidant elastomers are a promising localized therapy to inhibit neointimal hyperplasia. This work is focused on the development of poly(diol- co -citrate- co -ascorbate) (POCA) elastomers with tunable properties for coating ePTFE vascular grafts. A bioactive POCA elastomer (@20 : 20 : 8, [citrate] : [diol] : [ascorbate]) coating was applied on a 1.5 mm diameter ePTFE vascular graft as the most promising therapeutic candidate for reducing neointimal hyperplasia. Surface ascorbate density on the POCA elastomer was increased to 67.5 ± 7.3 ng mg −1 cm −2 . The mechanical, antioxidant, biodegradable, and biocompatible properties of POCA demonstrated desirable performance for in vivo use, inhibiting human aortic smooth muscle cell proliferation, while supporting human aortic endothelial cells. POCA elastomer coating number was adjusted by a modified spin-coating method to prepare small-diameter ePTFE vascular grafts similar to natural vessels. A significant reduction in neointimal hyperplasia was observed after implanting POCA-coated ePTFE vascular grafts in a guinea pig aortic interposition bypass graft model. POCA elastomer thus offers a new avenue that shows promise for use in vascular engineering to improve long-term patency rates by coating small-diameter ePTFE vascular grafts. 
    more » « less
  3. Abstract

    Tracheal stenting currently using non‐degradable stents is commonplace for treatment of trauma, prolonged intubation related adult airway obstructions, and pediatric patients‐associated tracheal stenosis conditions. Degradable tracheal stent placement will avoid complications of stent removal and restenosis. Widespread reports exist on degradable magnesium alloys success for orthopedic and cardiovascular applications but none to date for intra tracheal use. This research explores the use of pure Mg, AZ31, and Mg‐3Y alloys for degradable tracheal stent assessment.In vitroevaluation of magnesium, prototype stents in a bioreactor simulate the airway environment and corrosion. Micro‐CT imaging and biocompatibility evaluation helped assess the 24‐week degradation of intraluminal alloy stents following implantation in a rat trachealin vivobypass model. Histological analysis indicate tissue response of the harvested stented trachea segments after each time point. Corrosion studies for each alloy indicate significant differences between the simulated and controlin vitroconditions. AZ31 exhibited the lowest volume loss of 6.8% in saline, while pure Mg displayed the lowest volume loss of 4.6% in simulated airway fluid (SAF), both at 1‐week time points. Significant differences in percentage of total volume lost after 6 months were determined between the alloys over time. MgY alloy displayed the slowest corrosion losing only 15.1% volume after 24 weeks of immersion. Additionally,in vitromagnesium alloy corrosion was not significantly different from the percentage of total volume lostin vivoat 1‐week time point. The study demonstrates promise of magnesium alloys for intraluminal tracheal stent application albeit viability of a clinically translatable model warrants further studies. © 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 107B: 1844–1853, 2019.

     
    more » « less
  4. Abstract

    Magnesium (Mg)‐based materials have shown great potentials for bioresorbable implant applications. Previous studies showed that Mg with 10 and 20 vol % β‐tricalcium phosphate (β‐TCP) composites produced by spark plasma sintering, improved mechanical properties when compared with pure Mg. The objectives of this study were to evaluate the degradation behaviors of Mg/10% β‐TCP and Mg/20% β‐TCP composites in revised stimulated body fluid (rSBF), and to determine their cytocompatibility with bone marrow derived mesenchymal stem cells (BMSCs) using the direct culture method. During the 11 days of immersion in rSBF, Mg/β‐TCP composites showed different degradation behaviors at different immersion periods, that is, the initial stage (0–1 hr), the mid‐term stage (1 hr to 2 days), and the long‐term stage (2−11 days). The counter effects of mass loss due to microgalvanic corrosion and mass gain due to deposition of Ca‐P containing layers resulted in slower Mg2+ion release for Mg/20% β‐TCP than Mg/10% β‐TCP in the mid‐term, but eventually 16% mass loss for Mg/20% β‐TCP and 10% mass loss for Mg/10% β‐TCP after 11 days of immersion. The in vitro studies with BMSCs showed the highest cell adhesion density (i.e., 68% of seeding density) on the plate surrounding the Mg/10% β‐TCP sample, that is, under the indirect contact condition of direct culture. The β‐TCP showed a positive effect on direct adhesion of BMSCs on the surface of Mg/β‐TCP composites. This study elucidated the degradation behaviors and the cytocompatibility of Mg/β‐TCP composites in vitro; and, further studies on Mg/ceramic composites are needed to determine their potential for clinical applications. © 2019 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 107B: 2238–2253, 2019.

     
    more » « less
  5. null (Ed.)
    In this study, a compact cold sprayed (CS) Ti coating was deposited on Mg alloy using a high pressure cold spray (HPCS) system. The wear and corrosion behavior of the CS Ti coating was compared with that of CS Al coating and bare Mg alloy. The Ti coating yielded lower wear rate compared to Al coating and Mg alloy. Electrochemical impedance spectroscopy (EIS) and cyclic potentiodynamic polarization (CPP) tests revealed that CS Ti coating can substantially reduce corrosion rate of AZ31B in chloride containing solutions compared to CS Al coating. Interestingly, Ti-coated Mg alloy demonstrated negative hysteresis loop, depicting repassivation of pits, in contrast to AZ31B and Al-coated AZ31B with positive hysteresis loops where corrosion potential (Ecorr) > repassivation potential (Erp); indicating irreversible growth of pits. AZ31B and Al-coated AZ31B were most susceptible to pitting corrosion, while Ti-coated Mg alloy indicated noticeable resistance to pitting in 3.5 wt % NaCl solution. In comparison to Al coating, Ti coating considerably separated the AZ31BMg alloy surface from the corrosive electrolyte during long term immersion test for 11 days. 
    more » « less