Title: Integration of Graphene Electrodes with 3D Skeletal Muscle Tissue Models
Abstract Integration of conductive electrodes with 3D tissue models can have great potential for applications in bioelectronics, drug screening, and implantable devices. As conventional electrodes cannot be easily integrated on 3D, polymeric, and biocompatible substrates, alternatives are highly desirable. Graphene offers significant advantages over conventional electrodes due to its mechanical flexibility and robustness, biocompatibility, and electrical properties. However, the transfer of chemical vapor deposition graphene onto millimeter scale 3D structures is challenging using conventional wet graphene transfer methods with a rigid poly (methyl methacrylate) (PMMA) supportive layer. Here, a biocompatible 3D graphene transfer method onto 3D printed structure using a soft poly ethylene glycol diacrylate (PEGDA) supportive layer to integrate the graphene layer with a 3D engineered ring of skeletal muscle tissue is reported. The use of softer PEGDA supportive layer, with a 105times lower Young's modulus compared to PMMA, results in conformal integration of the graphene with 3D printed pillars and allows electrical stimulation and actuation of the muscle ring with various applied voltages and frequencies. The graphene integration method can be applied to many 3D tissue models and be used as a platform for electrical interfaces to 3D biological tissue system.  more » « less
Award ID(s):
1720633 1735252
PAR ID:
10457887
Author(s) / Creator(s):
 ;  ;  ;  ;  ;  ;  ;  ;  
Publisher / Repository:
Wiley Blackwell (John Wiley & Sons)
Date Published:
Journal Name:
Advanced Healthcare Materials
Volume:
9
Issue:
4
ISSN:
2192-2640
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. Abstract A key challenge in bioelectronics is to establish and improve the interface between electronic devices and living tissues, enabling a direct assessment of biological systems. Sensors integrated with plant tissue can provide valuable information about the plant itself as well as the surrounding environment, including air and soil quality. An obstacle in developing interfaces to plant tissue is mitigating the formation of fibrotic tissues, which can hinder continuous and accurate sensor operation over extended timeframes. Electronic systems that utilize suitable biocompatible materials alongside appropriate fabrication techniques to establish plant-electronic interfaces could provide for enhanced environmental understanding and ecosystem management capabilities. To meet these demands, this study introduces an approach for integrating printed electronic materials with biocompatible cryogels, resulting in stable implantable hydrogel-based bioelectronic devices capable of long-term operation within plant tissue. These inkjet-printed cryogels can be customized to provide various electronic functionalities, including electrodes and organic electrochemical transistors (OECTs), that exhibit high electrical conductivity for embedded conducting polymer traces (up to 350 S/cm), transconductance for OECTs in the mS range, a capacitance of up to 4.2 mF g−1in suitable structures, high stretchability (up to 330% strain), and self-healing properties. The biocompatible functionalized cryogel-based electrodes and transistors were successfully implanted in plant tissue, and ionic activity in tomato plant stems was collected for over two months with minimal scar tissue formation, making these cryogel-based printed electronic devices excellent candidates for continuous, in-situ monitoring of plant and environmental status and health. 
    more » « less
  2. ABSTRACT In today’s technology, organ transplantation is found very challenging as it is not easy to find the right donor organ in a short period of time. In the last several decades, tissue engineering was rapidly developed to be used as an alternative approach to the organ transplantation. Tissue engineering aims to regenerate the tissues and also organs to help patients who waits for the organ transplantation. Recent research showed that in order to regenerate the tissues, cells must be seeded onto the 3D artificial laboratory fabricated matrices called scaffolds. If cells show healthy growth within the scaffolds, they can be implanted to the injured tissue to do the regeneration. One of the biggest limitation that reduces the success rate of tissue regeneration is the fabrication of accurate thick 3D scaffolds. In this research “maskless photolithography” was used to fabricate the scaffolds. Experiment setup consist of digital micro-mirror devices (DMD) (Texas Instruments, DLi4120), optical lens sets, UV light source (DYMAX, BlueWave 200) and PEGDA which is a liquid form photo-curable solution. In this method, scaffolds are fabricated in layer-by-layer fashion to control the interior architecture of the scaffolds. Working principles of the maskless photolithography is, first layer shape is designed with AutoCAD and the designed image is uploaded to the DMD as a bitmap file. DMD consists of hundreds of tiny micro-mirrors. When the UV light is turned on and irradiated the DMD, depending on the micro-mirrors’ angles, UV light is selectively reflected to the low percentage Polyethylene (glycol) Diacrylate (PEGDA) photo-curable solution. When UV light penetrates into the PEGDA, only the illuminated part is solidified and non-illuminated area still remains in the liquid phase. In this research, scaffolds were fabricated in three layers. First layer and the last layer are solid layers and y-shape open structure was sandwiched between these layers. After the first layer is fabricated with DMD, a “y-shape” structure was fabricated with the 3D printer by using the dissolvable filament. Then, it was placed onto the first solid layer and covered with fresh high percentage PEGDA solution. UV light was reflected to the PEGDA solution and solidified to make the second and third layers. After the scaffold was fabricated, it is dipped into the limonene solution to dissolve the y-shape away. Our results show that thick scaffolds can be fabricated in layer-by-layer fashion with “maskless photolithography”. Since the UV light is stable and does not move onto the PEGDA, entire scaffold can be fabricated in one single UV shot which makes the process faster than the current fabrication techniques. 
    more » « less
  3. Abstract Epidermal sensors for remote healthcare and performance monitoring require the ability to operate under the effects of bodily motion, heat, and perspiration. Here, the use of purpose‐synthesized polymer‐based dry electrodes and graphene‐based strain gauges to obtain measurements of swallowed volume under typical conditions of exercise is evaluated. The electrodes, composed of the common conductive polymer poly(3,4 ethylenedioxythiophene) (PEDOT) electrostatically bound to poly(styrenesulfonate)‐b‐poly(poly(ethylene glycol) methyl ether acrylate) (PSS‐b‐PPEGMEA), collect surface electromyography (sEMG) signals on the submental muscle group, under the chin. Simultaneously, the deformation of the surface of the skin is measured using strain gauges comprising single‐layer graphene supporting subcontinuous coverage of gold and a highly plasticized composite containing PEDOT:PSS. Together, these materials permit high stretchability, high resolution, and resistance to sweat. A custom printed circuit board (PCB) allows this multicomponent system to acquire strain and sEMG data wirelessly. This sensor platform is tested on the swallowing activity of a cohort of 10 subjects while walking or cycling on a stationary bike. Using a machine learning (ML) model, it is possible to predict swallowed volume with absolute errors of 36% for walking and 43% for cycling. 
    more » « less
  4. ABSTRACT Despite their high power density, microsupercapacitors (MSCs) are impractical for many energy storage applications due to their limited energy density. Their energy density can be increased by shaping the electrodes into 3D structures with high specific surface area (SSA). Direct printing of nanoporous 3D electrodes is a promising approach for achieving high SSA. However, conventional nanoscale 3D printing is too slow due to point‐by‐point processing. Here, we have employed the projection two‐photon lithography technique to fabricate nanoporous 3D electrodes via a rapid layer‐by‐layer mechanism. The 3D MSC electrodes are engineered as an array of nanoporous polymeric micropillars that are printed with customizable spacing and count over a 0.25 cm2area. After printing, these micropillars are conformally coated with titanium nitride to form conductive 3D electrodes, which exhibit a specific capacitance of 361 μF/cm2. This is two orders of magnitude higher than the capacitance of the flat surface and exceeds the capacitance of both traditional bare electrodes, such as single‐wall carbon nanotubes (< 100 μF/cm2), and electrodes produced by photo‐polymerization 3D printing (˜200 μF/cm2). As our work demonstrates that high energy density 3D electrodes can be rapidly fabricated, it significantly expands the utility of MSCs as miniaturized energy storage devices. 
    more » « less
  5. Boland, Thomas (Ed.)
    The conventional real-time screening in organs-on-chips is limited to optical tracking of pre-tagged cells and biological agents. This work introduces an efficient biofabrication protocol to integrate tunable hydrogel electrodes into 3D bioprinted-on-chips. We established our method of fabricating cell-laden hydrogel-based microfluidic chips through digital light processing-based 3D bioprinting. Our conductive ink includes poly-(3,4-ethylene-dioxythiophene)-polystyrene sulfonate (PEDOT: PSS) microparticles doped in polyethylene glycol diacrylate (PEGDA). We optimized the manufacturing process of PEDOT: PSS microparticles characterized our conductive ink for different 3D bioprinting parameters, geometries, and materials conditions. While the literature is limited to 0.5% w/v for PEDOT: PSS microparticle concentration, we increased their concentration to 5% w/v with superior biological responses. We measured the conductivity in the 3–15 m/m for a range of 0.5%–5% w/v microparticles, and we showed the effectiveness of 3D-printed electrodes for predicting cell responses when encapsulated in gelatin-methacryloyl (GelMA). Interestingly, a higher cellular activity was observed in the case of 5% w/v microparticles compared to 0.5% w/v microparticles. Electrochemical impedance spectroscopy measurements indicated significant differences in cell densities and spheroid sizes embedded in GelMA microtissues. 