skip to main content


Title: 3D imaging of aqueous veins and surrounding sclera using a dual-wavelength photoacoustic microscopy

Understanding aqueous outflow resistance at the level of aqueous veins has been a challenge to the management of glaucoma. This study investigated resolving the anatomies of aqueous veins and the textures of surrounding sclera using photoacoustic microscopy (PAM). A dual wavelength PAM system was established and validated using imaging phantoms, porcine and human globes perfused with an optical contrast agentex vivo. The system shows lateral resolution of 8.23 µm and 4.70 µm at 1200 nm and 532 nm, respectively, and an axial resolution of 27.6 µm. The system is able to separately distinguish the aqueous veins and the sclera with high contrast in full circumference of the porcine and human globes.

 
more » « less
NSF-PAR ID:
10474332
Author(s) / Creator(s):
; ; ; ; ; ; ; ;
Publisher / Repository:
Optical Society of America
Date Published:
Journal Name:
Biomedical Optics Express
Volume:
14
Issue:
12
ISSN:
2156-7085
Format(s):
Medium: X Size: Article No. 6291
Size(s):
["Article No. 6291"]
Sponsoring Org:
National Science Foundation
More Like this
  1. Abstract A method motivated by the eye’s aqueous veins is described for the imaging and strain calculation within soft biological tissues. A challenge to the investigation of the biomechanics of the aqueous vein—perilimbal sclera tissue complex is resolution of tissue deformations as a function of intraocular pressure and the subsequent calculation of strain (a normalized measure of deformation). The method involves perfusion of the eye with a contrast agent during conduction of non-invasive, optical resolution photoacoustic microscopy. This imaging technique permits three-dimensional displacement measurements of tracked points on the inner walls of the veins which are used in a finite element model to determine the corresponding strains. The methods are validated against two standard strain measurement methods. Representative porcine globe perfusion experiments are presented that demonstrate the power of the method to determine complex strain fields in the veins dependent on intraocular pressure as well as vein anatomy. In these cases, veins are observed to move radially outward during increases in intraocular pressure and to possess significant spatial strain variation, possibly influenced by their branching patterns. To the authors’ knowledge, these are the only such quantitative, data driven, calculations of the aqueous vein strains available in the open literature. 
    more » « less
  2. Multi-parametric photoacoustic microscopy (PAM) is uniquely capable of simultaneous high-resolution mapping of blood oxygenation and flowin vivo. However, its speed has been limited by the dense sampling required for blood flow quantification. To overcome this limitation, we have developed a high-speed multi-parametric PAM system, which enables simultaneous acquisition of ∼500 densely sampled B-scans by superposing the rapid optical scanning across the line-shaped focus of a cylindrically focused ultrasonic transducer over the conventional mechanical scan of the optical-acoustic dual foci. A novel, to the best of our knowledge, optical-acoustic combiner (OAC) is designed and implemented to accommodate the short working distance of the transducer, enabling convenient confocal alignment of the dual foci in reflection mode. A resonant galvanometer (GM) provides stabilized high-speed large-angle scanning. This new system can continuously monitor microvascular blood oxygenation (sO2) and flow over a 4.5 × 3 mm2area in the awake mouse brain with high spatial and temporal resolutions (6.9 µm and 0.3 Hz, respectively).

     
    more » « less
  3. This Letter reports acoustic-resolution-photoacoustic microscopy (AR-PAM) based on a new optically transparent focused polyvinylidene fluoride (PVDF) transducer with a high acoustic numerical aperture (NA) of 0.64. Owing to the improved fabrication process, the new transducer has a much higher NA (0.64) than the previously reported low-NA transducer (NA=0.23). The acoustic center frequency and (pulse-echo) bandwidth are also increased to 36 and 44 MHz, respectively, which provides a 38 µm acoustic focal spot size and 210 µm acoustic depth of focus. For demonstration, AR-PAM was conducted on a twisted wire target in water and chicken breast tissue, andin vivoon a mouse tail. The imaging results show that high acoustic resolution and sensitivity can be achieved with a simple and compact setup to resolve the target at different depths. Such capabilities can be useful for the development of new AR-PAM systems for handheld, wearable, and even endoscopic imaging applications.

     
    more » « less
  4. Abstract Background

    Optical coherence tomography (OCT) has the potential to provide real‐time imaging guidance for atrial fibrillation ablation, with promising results for lesion monitoring. OCT can also offer high‐resolution imaging of tissue composition, but there is insufficient cardiac OCT data to inform the use of OCT to reveal important tissue architecture of the human left atrium. Thus, the objective of this study was to define OCT imaging data throughout the human left atrium, focusing on the distribution of adipose tissue and fiber orientation as seen from the endocardium.

    Methods and Results

    Human hearts (n = 7) were acquired for imaging the left atrium with OCT. A spectral‐domain OCT system with 1325 nm center wavelength, 6.5 μm axial resolution, 15 μm lateral resolution, and a maximum imaging depth of 2.51 mm in the air was used. Large‐scale OCT image maps of human left atrial tissue were developed, with adipose thickness and fiber orientation extracted from the imaging data. OCT imaging showed scattered distributions of adipose tissue around the septal and pulmonary vein regions, up to a depth of about 0.43 mm from the endocardial surface. The total volume of adipose tissue detected by OCT over one left atrium ranged from 1.42 to 28.74 mm3. Limited fiber orientation information primarily around the pulmonary veins and the septum could be identified.

    Conclusion

    OCT imaging could provide adjunctive information on the distribution of subendocardial adipose tissue, particularly around thin areas around the pulmonary veins and septal regions. Variations in OCT‐detected tissue composition could potentially assist ablation guidance.

     
    more » « less
  5. Abstract

    Additive manufacturing systems that can arbitrarily deposit multiple materials into precise, 3D spaces spanning the micro‐ to nanoscale are enabling novel structures with useful thermal, electrical, and optical properties. In this companion paper set, electrohydrodynamic jet (e‐jet) printing is investigated for its ability in depositing multimaterial, multilayer films with microscale spatial resolution and nanoscale thickness control, with a demonstration of this capability in creating 1D photonic crystals (1DPCs) with response near the visible regime. Transfer matrix simulations are used to evaluate different material classes for use in a printed 1DPC, and commercially available photopolymers with varying refractive indices (n= 1.35 to 1.70) are selected based on their relative high index contrast and fast curing times. E‐jet printing is then used to experimentally demonstrate pixelated 1DPCs with individual layer thicknesses between 80 and 200 nm, square pixels smaller than 40 µm across, with surface roughness less than 20 nm. The reflectance characteristics of the printed 1DPCs are measured using spatially selective microspectroscopy and correlated to the transfer matrix simulations. These results are an important step toward enabling cost‐effective, custom‐fabrication of advanced imaging devices or photonic crystal sensing platforms.

     
    more » « less