Title: Fueling the seaport of the future: Investments in low‐carbon energy technologies for operational resilience in seaport multi‐energy systems
Abstract The ability to withstand and recover from disruptions is essential for seaport energy systems, and in light of the growing push for decarbonization, incorporating clean energy sources has become increasingly imperative to ensure resilience. This paper proposes a resilience enhancement planning strategy for a seaport multi‐energy system that integrates various energy modalities and sources, including heating, cooling, hydrogen, solar, and wind power. The planning strategy aims to ensure the reliable operation of the system during contingency events, such as power outages, equipment failures, or extreme weather incidents. The proposed optimization model is designed as a mixed‐integer nonlinear programming formulation, in which McCormick inequalities and other linearization techniques are utilized to tackle the model nonlinearities. The model allocates fuel cell electric trucks (FCETs), renewable energy sources, hydrogen refueling stations, and remote control switches such that the system resilience is enhanced while incorporating natural‐gas‐powered combined cooling, heating, and power system to minimize the operation and unserved demand costs. The model considers various factors such as the availability of renewable energy sources, the demand for heating, cooling, electricity, and hydrogen, the operation of remote control switches to help system reconfiguration, the travel behaviour of FCETs, and the power output of FCETs via vehicle‐to‐grid interface. The numerical results demonstrate that the proposed strategy can significantly improve the resilience of the seaport multi‐energy system and reduce the risk of service disruptions during contingency scenarios.  more » « less
Award ID(s):
2114100
PAR ID:
10476354
Author(s) / Creator(s):
 ;  ;  
Publisher / Repository:
DOI PREFIX: 10.1049
Date Published:
Journal Name:
IET Generation, Transmission & Distribution
Volume:
18
Issue:
2
ISSN:
1751-8687
Format(s):
Medium: X Size: p. 248-265
Size(s):
p. 248-265
Sponsoring Org:
National Science Foundation
More Like this
  1. null (Ed.)
    The electrical power system is the backbone of our nations critical infrastructure. It has been designed to withstand single component failures based on a set of reliability metrics which have proven acceptable during normal operating conditions. However, in recent years there has been an increasing frequency of extreme weather events. Many have resulted in widespread long-term power outages, proving reliability metrics do not provide adequate energy security. As a result, researchers have focused their efforts resilience metrics to ensure efficient operation of power systems during extreme events. A resilient system has the ability to resist, adapt, and recover from disruptions. Therefore, resilience has demonstrated itself as a promising concept for currently faced challenges in power distribution systems. In this work, we propose an operational resilience metric for modern power distribution systems. The metric is based on the aggregation of system assets adaptive capacity in real and reactive power. This metric gives information to the magnitude and duration of a disturbance the system can withstand. We demonstrate resilience metric in a case study under normal operation and during a power contingency on a microgrid. In the future, this information can be used by operators to make more informed decisions based on system resilience in an effort to prevent power outages. 
    more » « less
  2. Transmission expansion planning (TEP) plays a vital role in ensuring the reliable and efficient operation of power systems, especially with the growing demand for electricity and the integration of renewable energy sources. This paper focuses on applying unconventional high surge impedance loading (HSIL) lines in transmission expansion planning and compares their outcomes with conventional line-based transmission expansion planning. Starting with a 17 bus- 500 kV power system connected by a conventional transmission line, the objective is to connect a new load located in a new bus, bus #18, to the existing 17-bus power system via two approaches: using conventional lines and incorporating unconventional HSIL lines. By comparing the number of lines required for the conventional and unconventional approaches, maintaining almost identical conductor volume per circuit, the effectiveness of unconventional HSIL lines in TEP is evaluated where using only two unconventional HSIL lines is sufficient to connect 1000 MW load demand at bus 18 while three lines are required when using the conventional design. 
    more » « less
  3. Transmission expansion planning (TEP) is crucial for maintaining the reliable and efficient operation of the power systems, particularly in the face of increasing electricity demand and the integration of renewable energy sources. This paper aims to investigate the application of unconventional high surge impedance loading (HSIL) lines in TEP and presents a comparative analysis of their outcomes against conventional line-based TEP approaches. Starting with a 17-bus 500 kV test system, which can operate well under normal operating condition as well as all single contingency conditions, the objective is to connect a new load located in a new bus, bus #18, to the existing test system via two approaches: using conventional lines and incorporating unconventional HSIL lines. By comparing the number of lines required for the conventional and unconventional approaches, maintaining identical conductor weight per circuit, the effectiveness of unconventional HSIL lines in TEP is evaluated where using only two unconventional HSIL lines is sufficient to connect 1250 MW load demand at bus 18 while three transmission lines are required when using the conventional line. Finally, a thorough economic analysis has been conducted on both TEP scenarios, revealing that implementing unconventional HSIL lines leads to remarkable cost savings and thus can be considered a promising option for TEP studies. 
    more » « less
  4. Space cooling constitutes >10% of worldwide electricity consumption and is anticipated to rise swiftly due to intensified heatwaves under emerging climate change. The escalating electricity demand for cooling services will challenge already stressed power grids, especially during peak times of demand. To address this, the adoption of demand response to adjust building energy use on the end-user side becomes increasingly important to adapt future smart buildings with rapidly growing renewable energy sources. However, existing demand response strategies predominantly explore sensible cooling energy as flexible building load while neglecting latent cooling energy, which constitutes significant portions of total energy use of buildings in humid climates. Hence, this paper aims to evaluate the demand response potential by adjusting latent cooling energy through ventilation control for typical medium commercial office buildings in four representative cities across different humid climate zones, i.e., Miami, Huston, Atlanta, and New York in the United States (US). As the first step, the sensible heat ratio, defined as sensible cooling load to total building load (involving both sensible and latent load), in different humid climates are calculated. Subsequently, the strategy to adjust building latent load through ventilation control (LLVC) is explored and implemented for demand response considering the balance of energy shifting, indoor air quality, and energy cost. Results reveal that adjusting building ventilation is capable of achieving 30%–40% Heating, Ventilation, and Air-conditioning (HVAC) cooling demand flexibility during HVAC operation while among this, the latent cooling energy contributes 56% ~ 66.4% to the overall demand flexibility. This work provides a feasible way to improve electricity grid flexibility in humid climates, emphasizing the significant role of adjusting latent cooling energy in building demand response. 
    more » « less
  5. With increasing concerns about climate change, there is a transition from high-carbon-emitting fuels to green energy resources in various applications including household, commercial, transportation, and electric grid applications. Even though renewable energy resources are receiving traction for being carbon-neutral, their availability is intermittent. To address this issue to achieve extensive application, the integration of energy storage systems in conjunction with these resources is becoming a recommended practice. Additionally, in the transportation sector, the increased demand for EVs requires the development of energy storage systems that can deliver energy for rigorous driving cycles, with lithium-ion-based batteries emerging as the superior choice for energy storage due to their high power and energy densities, length of their life cycle, low self-discharge rates, and reasonable cost. As a result, battery energy storage systems (BESSs) are becoming a primary energy storage system. The high-performance demand on these BESS can have severe negative effects on their internal operations such as heating and catching on fire when operating in overcharge or undercharge states. Reduced efficiency and poor charge storage result in the battery operating at higher temperatures. To mitigate early battery degradation, battery management systems (BMSs) have been devised to enhance battery life and ensure normal operation under safe operating conditions. Some BMSs are capable of determining precise state estimations to ensure safe battery operation and reduce hazards. Precise estimation of battery health is computed by evaluating several metrics and is a central factor in effective battery management systems. In this scenario, the accurate estimation of the health indicators (HIs) of the battery becomes even more important within the framework of a BMS. This paper provides a comprehensive review and discussion of battery management systems and different health indicators for BESSs, with suitable classification based on key characteristics. 
    more » « less