skip to main content
US FlagAn official website of the United States government
dot gov icon
Official websites use .gov
A .gov website belongs to an official government organization in the United States.
https lock icon
Secure .gov websites use HTTPS
A lock ( lock ) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.


Title: Trapping proteins on nanopores by dielectrophoresis
Interest in the phenomenon of dielectrophoresis has gained significant attention in recent years due to its potential for sorting, manipulation, and trapping of solutes, such as proteins, in aqueous solutions. For many decades, protein dielectrophoresis was considered impossible, as the predicted magnitude of the force arising from experimentally accessible field strengths could not out-compete thermal energy. This conclusion was drawn from the mainstay Clausius–Mossotti (CM) susceptibility applied to the dielectrophoretic force. However, dielectric interfacial polarization leading to the CM result does not account for a large protein dipole moment that is responsible for the dipolar mechanism of dielectrophoresis outcompeting the CM induction mechanism by three to four orders of magnitude in the case of proteins. Here, we propose an explicit geometry within which the dipolar susceptibility may be put to the test. The electric field and dielectrophoretic force are explicitly calculated, and the dependence of the trapping distance on the strength of the applied field is explored. A number of observable distinctions between the dipolar and induction mechanisms are identified.  more » « less
Award ID(s):
2154465
PAR ID:
10493967
Author(s) / Creator(s):
;
Publisher / Repository:
AIP
Date Published:
Journal Name:
Journal of Applied Physics
Volume:
133
Issue:
16
ISSN:
0021-8979
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. Dielectrophoresis (DEP) is a label-free electrokinetic method for selectively trapping polarizable particles using non-uniform electric fields. While co-planar electrode systems are common, their inherent DEP force distribution limits throughput. This study presents a computationally efficient framework for modeling two-dimensional DEP-based particle trapping in ordered arrays of conductive cylinders. These cylinders are modeled at a range of sizes, from micrometers to nanometers, to represent microfluidic systems consisting of conductive pillars, nanofibers, etc. Analytical solutions for fluid flow and electric potential were derived using eigenfunction expansions and collocation, then used in a particle tracking model that includes hydrodynamic drag, Brownian motion, and multipolar DEP forces. Although focused on conductive arrays, this framework is extensible to other configurations. This work provides a foundation for future work in the design of high-throughput DEP systems. Both dimensionless and dimensional analyses were performed across a wide range of particle sizes (30 nm to 3 μm), voltages (10 mV to 100 V), and array geometries. No specific optimal cylinder size was found; instead, optimal performance arises from a balance between DEP force distribution and flow through the cylinder array gap. Diamond-oriented arrays exhibited enhanced trapping under moderate dielectrophoretic velocity-to-fluid velocity ratios (up to 39% greater), while square arrays performed better under low-field and large-cylinder conditions (up to 40% greater). 
    more » « less
  2. Abstract Dielectrophoresis is a well‐understood phenomenon that has been widely utilized in biomedical applications. Recent advancements in miniaturization have contributed to the development of dielectrophoretic‐based devices for a wide variety of biomedical applications. In particular, the integration of dielectrophoresis with microfluidics, fluorescence, and electrical impedance has produced devices and techniques that are attractive for screening and diagnosing diseases. This review article summarizes the recent utility of dielectrophoresis in assays of biomarker detection. Common screening and diagnostic biomarkers, such as cellular, protein, and nucleic acid, are discussed. Finally, the potential use of recent developments in machine learning approaches toward improving biomarker detection performance is discussed. This review article will be useful for researchers interested in the recent utility of dielectrophoresis in the detection of biomarkers and for those developing new devices to address current gaps in dielectrophoretic biomarker detection. 
    more » « less
  3. ABSTRACT While traditional dielectrophoretic methods for nanoparticle enrichment and filtration are versatile and selective, they struggle to handle higher throughput applications. To address this challenge and enhance the practical application of dielectrophoresis, we propose an innovative design for porous sandwiched nanofiber electrodes. The electrode is fabricated through a simple process involving the electrospinning of nanofibers with a diameter of 216 ± 28 nm and mat thickness of around 70 µm, followed by the deposition of a thin chromium/gold layer (approximately 140 nm thick) on both sides. This process ensures no electrical short circuit occurs between the electrodes, and it maintains a sheet resistance of 7.19 Ω/□. The resulting significant electric field gradients are capable of trapping nanoparticles with diameters of 100 nm and 40 nm. The structure's sub‐micrometer features and large active surface area allow for trapping of nanoparticles at a flow rate of 3.6 mL/h. To evaluate the effects of applied voltage and volumetric flow rate, we conducted experiments with constant voltage while varying the flow rate and constant flow rate while varying the voltage. Our findings indicate that trapping performance improves with higher AC voltage but decreases at higher flow rates. These insights are crucial for optimizing parameters for large‐scale nanoparticle enrichment and filtration. This proof‐of‐concept study for flow through dielectrophoresis of nanoparticles paves the way for a device suitable for large‐scale sample processing and higher throughput/separation efficiency in practical settings. 
    more » « less
  4. Molecular dynamics simulations of a small redox-active protein plastocyanin address two questions. (i) Do protein electrostatics equilibrate to the Gibbsian ensemble? (ii) Do the electrostatic potential and electric field inside proteins follow the Gaussian distribution? The statistics of electrostatic potential and electric field are probed by applying small charge and dipole perturbations to different sites within the protein. Nonergodic (non-Gibbsian) sampling is detectable through violations of exact statistical rules constraining the first and second statistical moments (fluctuation–dissipation relations) and the linear relation between free-energy surfaces of the collective coordinate representing the Hamiltonian electrostatic perturbation. We find weakly nonergodic statistics of the electrostatic potential (simulation time of 0.4–1.0 μs) and non-Gibbsian and non-Gaussian statistics of the electric field. A small dipolar perturbation of the protein results in structural instabilities of the protein–water interface and multi-modal distributions of the Hamiltonian energy gap. The variance of the electrostatic potential passes through a crossover at the glass transition temperature Ttr ≃ 170 K. The dipolar susceptibility, reflecting the variance of the electric field inside the protein, strongly increases, with lowering temperature, followed by a sharp drop at Ttr. The linear relation between free-energy surfaces can be directly tested by combining absorption and emission spectra of optical dyes. It was found that the statistics of the electrostatic potential perturbation are nearly Gibbsian/Gaussian, with little deviations from the prescribed statistical rules. On the contrary, the (nonergodic) statistics of dipolar perturbations are strongly non-Gibbsian/non-Gaussian due to structural instabilities of the protein hydration shell. 
    more » « less
  5. Abstract A simple, low‐cost, three‐dimensional (3D) lab‐on‐a‐foil microfluidic device for dielectrophoretic separation of circulating tumor cells (CTCs) is designed and constructed. Disposable thin films are cut by xurography and microelectrode array are made with rapid inkjet printing. The multilayer device design allows the studying of spatial movements of CTCs and red blood cells (RBCs) under dielectrophoresis (DEP). A numerical simulation was performed to find the optimum driving frequency of RBCs and the crossover frequency for CTCs. At the optimum frequency, RBCs were lifted 120 µm inz‐axis direction by DEP force, and CTCs were not affected due to negligible DEP force. By utilizing the displacement difference, the separation of CTCs (modeled with A549 lung carcinoma cells) from RBCs inz‐axis direction was achieved. With the nonuniform electric field at optimized driving frequency, the RBCs were trapped in the cavities above the microchannel, whereas the A549 cells were separated with a high capture rate of 86.3% ± 0.2%. The device opens not only the possibility for 3D high‐throughput cell separation but also for future developments in 3D cell manipulation through rapid and low‐cost fabrication. 
    more » « less