Surfactants are often added to particle suspensions in the flow of Newtonian or non-Newtonian fluids for the purpose of reducing particle-particle aggregation and particle-wall adhesion. However, the impact on the flow behavior of such surfactant additions is often overlooked. We experimentally investigate the effect of the addition of a frequently used neutral surfactant, Tween 20, at the concentration pertaining to microfluidic applications on the entry flow of water and three common polymer solutions through a planar cavity microchannel. We find that the addition of Tween 20 has no significant influence on the shear viscosity or extensional flow of Newtonian water and Boger polyethylene oxide solution. However, such a surfactant addition reduces both the shear viscosity and shear-thinning behavior of xanthan gum and polyacrylamide solutions that each exhibit a strong shear-thinning effect. It also stabilizes the cavity flow and delays the onset of flow instability in both cases. The findings of this work can directly benefit microfluidic applications of particle and cell manipulation in Newtonian and non-Newtonian fluids.
more »
« less
Effects of Tween 20 addition on electrokinetic transport in a polydimethylsiloxane microchannel
Abstract Tween 20 is frequently added to particle suspensions for reducing the particle–wall adhesion and particle–particle aggregation in microfluidic devices. However, the influences of Tween 20 on the fluid and particle behaviors have been largely ignored. We present in this work the first experimental study of the effects of Tween 20 addition on the electrokinetic transport of fluids and particles in a polydimethylsiloxane microchannel. We find that adding 0.1% v/v Tween 20 to a buffer solution can significantly reduce the electroosmotic mobility as well as the electrokinetic and electrophoretic mobilities of polystyrene particles and yeast cells. Further increasing the Tween 20 concentration within the range typically used in microfluidic applications continues reducing these mobility values, but at a smaller rate. Our finding suggests that Tween 20 should be used with care in electrokinetic microdevices when the flow rate or particle/cell throughput is an important parameter.
more »
« less
- PAR ID:
- 10500309
- Publisher / Repository:
- Willey
- Date Published:
- Journal Name:
- ELECTROPHORESIS
- ISSN:
- 0173-0835
- Format(s):
- Medium: X
- Sponsoring Org:
- National Science Foundation
More Like this
-
-
Insulator-based microfluidic devices are attractive for handling biological samples due to their simple fabrication, low-cost, and efficiency in particle manipulation. However, their widespread application is limited by the high operation voltages required to achieve particle trapping. We present a theoretical, numerical, and experimental study that demonstrates these voltages can be significantly reduced (to sub-100 V) in direct-current insulator-based electrokinetic (DC-iEK) devices for micron-sized particles. To achieve this, we introduce the concept of the amplification factor—the fold-increase in electric field magnitude due to the presence of an insulator constriction—and use it to compare the performance of different microchannel designs and to direct our design optimization process. To illustrate the effect of using constrictions with smooth and sharp features on the amplification factor, geometries with circular posts and semi-triangular posts were used. These were theoretically approximated in two different systems of coordinates (bipolar and elliptic), allowing us to provide, for the first time, explicit electric field amplification scaling laws. Finite element simulations were performed to approximate the 3D insulator geometries and provide a parametric study of the effect of changing different geometrical features. These simulations were used to predict particle trapping voltages for four different single-layer microfluidic devices using two particle suspensions (2 and 6.8 μm in size). The general agreement between our models demonstrates the feasibility of using the amplification factor, in combination with nonlinear electrokinetic theory, to meet the prerequisites for the development of portable DC-iEK microfluidic systems.more » « less
-
Previous studies have reported a lateral migration in particle electrophoresis through a straight rectangular microchannel. This phenomenon arises from the inherent wall-induced electrical lift that can be exploited to focus and separate particles for microfluidic applications. Such a dielectrophoretic-like force has been recently found to vary with the buffer concentration. We demonstrate in this work that the particle zeta potential also has a significant effect on the wall-induced electrical lift. We perform an experimental study of the lateral migration of equal-sized polystyrene particles with varying surface charges under identical electrokinetic flow conditions. Surprisingly, an enhanced focusing is observed for particles with a faster electrokinetic motion, which indicates a substantially larger electrical lift for particles with a smaller zeta potential. We speculate this phenomenon may be correlated with the particle surface conduction that is a strong function of particle and fluid properties.more » « less
-
Bacteriophage therapy presents a promising avenue for combating antibiotic-resistant bacterial infections. Yet, challenges exist, particularly, the lack of a straightforward purification pipeline suitable for widespread application to many phage types, as some phages are known to undergo significant titer loss when purified via current techniques. Electrokinetic methods offer a potential solution to this hurdle, with nonlinear electrophoresis emerging as a particularly appealing approach due to its ability to discern both the size and shape of the target phage particles. Presented herein is the electrokinetic characterization of the mobility of nonlinear electrophoresis for two phages (SPN3US and ϕKZ) and three types of polystyrene nanoparticles. The latter served as controls and were selected based on their sizes and surface charge magnitude. Particle tracking velocimetry experiments were conducted to characterize the mobility of all five particles included in this study. The results indicated that the selected nanoparticles effectively replicate the migration behavior of the two phages under electric fields. Further, it was found that there is a significant difference in the nonlinear electrophoretic response of phages and that of host cells, as first characterized in a previous report, illustrating that electrokinetic-based separations are feasible. The findings from this work are the first characterization of the behavior of phages under nonlinear electrophoresis effects and illustrate the potential for the development of electrokinetic-based phage purification techniques that could aid the advancement of bacteriophage therapy.more » « less
-
Analyte migration order is a major aspect in all migration-based analytical separations methods. Presented here is the manipulation of the migration order of microparticles in an insulator-based electrokinetic separation. Three distinct particle mixtures were studied: a binary mixture of particles with similar electrical charge and different sizes, and two tertiary mixtures of particles of distinct sizes. Each one of the particle mixtures was separated twice, the first separation was performed under low voltage (linear electrokinetic regime) and the second separation was performed under high voltage (nonlinear electrokinetic regime). Linear electrophoresis, which discriminates particles by charge, is the dominant electrokinetic effect in the linear regime; while nonlinear electrophoresis, which discriminates particles by size and shape, is the dominant electrokinetic effect in the nonlinear regime. The separation results obtained with the three particle mixtures illustrated that particle elution order can be changed by switching from the linear electrokinetic regime to the nonlinear electrokinetic regime. Also, in all cases, better separation performances in terms of separation resolution (Rs) were obtained by employing the nonlinear electrokinetic regime allowing nonlinear electrophoresis to be the discriminatory electrokinetic mechanism. These findings could be applied to analyze complex samples containing bioparticles of interest within the micron size range. This is the first report where particle elution order is altered in an iEK system.more » « less
An official website of the United States government

