Title: Spectroradiometry with sub-microsecond time resolution using multianode photomultiplier tube assemblies
Accurate and precise measurements of spectroradiometric temperature are crucial for many high pressure experiments that use diamond anvil cells or shock waves. In experiments with sub-millisecond timescales, specialized detectors such as streak cameras or photomultiplier tubes are required to measure temperature. High accuracy and precision are difficult to attain, especially at temperatures below 3000 K. Here, we present a new spectroradiometry system based on multianode photomultiplier tube technology and passive readout circuitry that yields a 0.24 µs rise-time for each channel. Temperature is measured using five color spectroradiometry. During high pressure pulsed Joule heating experiments in a diamond anvil cell, we document measurement precision to be ±30 K at temperatures as low as 2000 K during single-shot heating experiments with 0.6 µs time-resolution. Ambient pressure melting tests using pulsed Joule heating indicate that the accuracy is ±80 K in the temperature range 1800–2700 K.  more » « less
Award ID(s):
2125954
PAR ID:
10504415
Author(s) / Creator(s):
; ; ; ; ;
Publisher / Repository:
AIP
Date Published:
Journal Name:
Review of Scientific Instruments
Volume:
95
Issue:
2
ISSN:
0034-6748
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. Decades of measurements of the thermophysical properties of hot metals show that pulsed Joule heating is an effective method to heat solid and liquid metals that are chemically reactive or difficult to contain. To extend such measurements to hundreds of GPa pressure, pulsed heating methods have recently been integrated with diamond anvil cells. The recent design used a low-side switch and active electrical sensing equipment that was prone to damage and measurement error. Here, we report the design and characterization of new electronics that use a high-side switch and robust, passive electrical sensing equipment. The new pulse amplifier can heat ∼5 to 50 μm diameter metal wires to thousands of kelvin at tens to hundreds of GPa using diamond anvil cells. Pulse durations and peak currents can each be varied over three orders of magnitude, from 5 µs to 10 ms and from 0.2 to 200 A. The pulse amplifier is integrated with a current probe. Two voltage probes attached to the body of a diamond anvil cell are used to measure voltage in a four-point probe geometry. The accuracy of four-point probe resistance measurements for a dummy sample with 0.1 Ω resistance is typically better than 5% at all times from 2 µs to 10 ms after the beginning of the pulse. 
    more » « less
  2. A new diamond anvil cell experimental approach has been implemented at the European x-ray Free Electron Laser, combining pulsed laser heating with MHz x-ray diffraction. Here, we use this setup to determine liquidus temperatures under extreme conditions, based on the determination of time-resolved crystallization. The focus is on a Fe-Si-O ternary system, relevant for planetary cores. This time-resolved diagnostic is complemented by a finite-element model, reproducing temporal temperature profiles measured experimentally using streaked optical pyrometry. This model calculates the temperature and strain fields by including (i) pressure and temperature dependencies of material properties, and (ii) the heat-induced thermal stress, including feedback effect on material parameter variations. Making our model more realistic, these improvements are critical as they give 7000 K temperature differences compared to previous models. Laser intensities are determined by seeking minimal deviation between measured and modeled temperatures. Combining models and streak optical pyrometry data extends temperature determination below detection limit. The presented approach can be used to infer the liquidus temperature by the appearance of SiO2 diffraction spots. In addition, temperatures obtained by the model agree with crystallization temperatures reported for Fe–Si alloys. Our model reproduces the planetary relevant experimental conditions, providing temperature, pressure, and volume conditions. Those predictions are then used to determine liquidus temperatures at experimental timescales where chemical migration is limited. This synergy of novel time-resolved experiments and finite-element modeling pushes further the interpretation capabilities in diamond anvil cell experiments. 
    more » « less
  3. When diamond anvil cell (DAC) sample chambers are outfitted with both thermal insulation and electrodes, two cutting-edge experimental methods are enabled: Joule heating with spectroradiometric temperature measurement and electrical resistance measurements of samples heated to thousands of kelvin. The accuracy of temperature and resistance measurements, however, often suffers from poor control of the shape and location of the sample, electrodes, and thermal insulation. Here, we present a recipe for the reproducible and precise fabrication of DAC sample, electrodes, and thermal insulation using a three-layer microassembly. The microassembly contains two potassium chloride thermal insulation layers, four electrical leads, a sample, and a buttressing layer made of polycrystalline alumina. The sample, innermost electrodes, and buttress layer are fabricated by focused-ion-beam milling. Three iron samples are presented as proof of concept. Each is successfully compressed and pulsed Joule heated while maintaining a four-point probe configuration. The highest pressure-temperature condition achieved is ∼150 GPa and 4000 K. 
    more » « less
  4. Externally heated diamond anvil cells provide a stable and uniform thermal environment, making them a versatile device to simultaneously generate high-pressure and high-temperature conditions in various fields of research, such as condensed matter physics, materials science, chemistry, and geosciences. The present study features the Externally Heated Diamond ANvil Cell Experimentation (EH-DANCE) system, a versatile configuration consisting of a diamond anvil cell with a customized microheater for stable resistive heating, bidirectional pressure control facilitated by compression and decompression membranes, and a water-cooled enclosure suitable for vacuum and controlled atmospheres. This integrated system excels with its precise control of both pressure and temperature for mineral and materials science research under extreme conditions. We showcase the capabilities of the system through its successful application in the investigation of the melting temperature and thermal equation of state of high-pressure ice-VII at temperatures up to 1400 K. The system was also used to measure the elastic properties of solid ice-VII and liquid H2O using Brillouin scattering and Raman spectra of carbonates using Raman spectroscopy, highlighting the potential of the EH-DANCE system in high-pressure research. 
    more » « less
  5. Abstract The thermal conductivity of bridgmanite, the primary constituent of the Earth's lower mantle, has been investigated using diamond anvil cells at pressures up to 85 GPa and temperatures up to 3,100 K. We report the results of time‐domain optical laser flash heating and X‐ray Free Electron Laser heating experiments from a variety of bridgmanite samples with different Al and Fe contents. The results demonstrate that Fe or Fe,Al incorporation in bridgmanite reduces thermal conductivity by about 50% in comparison to end‐member MgSiO3at the pressure‐temperature conditions of Earth's lower mantle. The effect of temperature on the thermal conductivity at 28–60 GPa is moderate, well described as , whereais 0.2–0.5. The results yield thermal conductivity of 7.5–15 W/(m × K) in the thermal boundary layer of the lowermost mantle composed of Fe,Al‐bearing bridgmanite. 
    more » « less