skip to main content
US FlagAn official website of the United States government
dot gov icon
Official websites use .gov
A .gov website belongs to an official government organization in the United States.
https lock icon
Secure .gov websites use HTTPS
A lock ( lock ) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.


Title: Underwater optical signal detection system using diffuser-based lensless imaging
We propose a diffuser-based lensless underwater optical signal detection system. The system consists of a lensless one-dimensional (1D) camera array equipped with random phase modulators for signal acquisition and one-dimensional integral imaging convolutional neural network (1DInImCNN) for signal classification. During the acquisition process, the encoded signal transmitted by a light-emitting diode passes through a turbid medium as well as partial occlusion. The 1D diffuser-based lensless camera array is used to capture the transmitted information. The captured pseudorandom patterns are then classified through the 1DInImCNN to output the desired signal. We compared our proposed underwater lensless optical signal detection system with an equivalent lens-based underwater optical signal detection system in terms of detection performance and computational cost. The results show that the former outperforms the latter. Moreover, we use dimensionality reduction on the lensless pattern and study their theoretical computational costs and detection performance. The results show that the detection performance of lensless systems does not suffer appreciably. This makes lensless systems a great candidate for low-cost compressive underwater optical imaging and signal detection.  more » « less
Award ID(s):
2141473
PAR ID:
10527152
Author(s) / Creator(s):
; ; ;
Publisher / Repository:
Optica
Date Published:
Journal Name:
Optics Express
Volume:
32
Issue:
2
ISSN:
1094-4087
Page Range / eLocation ID:
1489
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. In this paper, we assess the noise-susceptibility of coherent macroscopic single random phase encoding (SRPE) lensless imaging by analyzing how much information is lost due to the presence of camera noise. We have used numerical simulation to first obtain the noise-free point spread function (PSF) of a diffuser-based SRPE system. Afterwards, we generated a noisy PSF by introducing shot noise, read noise and quantization noise as seen in a real-world camera. Then, we used various statistical measures to look at how the shared information content between the noise-free and noisy PSF is affected as the camera-noise becomes stronger. We have run identical simulations by replacing the diffuser in the lensless SRPE imaging system with lenses for comparison with lens-based imaging. Our results show that SRPE lensless imaging systems are better at retaining information between corresponding noisy and noiseless PSFs under high camera noise than lens-based imaging systems. We have also looked at how physical parameters of diffusers such as feature size and feature height variation affect the noise robustness of an SRPE system. To the best of our knowledge, this is the first report to investigate noise robustness of SRPE systems as a function of diffuser parameters and paves the way for the use of lensless SRPE systems to improve imaging in the presence of image sensor noise. 
    more » « less
  2. In this paper, we have used the angular spectrum propagation method and numerical simulations of a single random phase encoding (SRPE) based lensless imaging system, with the goal of quantifying the spatial resolution of the system and assessing its dependence on the physical parameters of the system. Our compact SRPE imaging system consists of a laser diode that illuminates a sample placed on a microscope glass slide, a diffuser that spatially modulates the optical field transmitting through the input object, and an image sensor that captures the intensity of the modulated field. We have considered two-point source apertures as the input object and analyzed the propagated optical field captured by the image sensor. The captured output intensity patterns acquired at each lateral separation between the input point sources were analyzed using a correlation between the captured output pattern for the overlapping point-sources, and the captured output intensity for the separated point sources. The lateral resolution of the system was calculated by finding the lateral separation values of the point sources for which the correlation falls below a threshold value of 35% which is a value chosen in accordance with the Abbe diffraction limit of an equivalent lens-based system. A direct comparison between the SRPE lensless imaging system and an equivalent lens-based imaging system with similar system parameters shows that despite being lensless, the performance of the SRPE system does not suffer as compared to lens-based imaging systems in terms of lateral resolution. We have also investigated how this resolution is affected as the parameters of the lensless imaging system are varied. The results show that SRPE lensless imaging system shows robustness to object to diffuser-to-sensor distance, pixel size of the image sensor, and the number of pixels of the image sensor. To the best of our knowledge, this is the first work to investigate a lensless imaging system’s lateral resolution, robustness to multiple physical parameters of the system, and comparison to lens-based imaging systems. 
    more » « less
  3. The study of high-speed phenomena in underwater environments is pivotal across diverse scientific and engineering domains. This paper introduces a high-speed (3D) integral imaging (InIm) based system to 1) visualize high-speed dynamic underwater events, and 2) detect modulated signals for potential optical communication applications. The proposed system is composed of a high-speed camera with a lenslet array-based integral imaging setup to capture and reconstruct 3D images of underwater scenes and detect temporally modulated optical signals. For 3D visualization, we present experiments to capture the elemental images of high-speed underwater events with passive integral imaging, which were then computationally reconstructed to visualize 3D dynamic underwater scenes. We present experiments for 3D imaging and reconstruct the depth map of high-speed underwater dynamic jets of air bubbles, offering depth information and visualizing the 3D movement of these jets. To detect temporally modulated optical signals, we present experiments to demonstrate the ability to capture and reconstruct high-speed underwater modulated optical signals in turbidity. To the best of our knowledge, this is the first report on high-speed underwater 3D integral imaging for 3D visualization and optical signal communication. The findings illustrate the potential of high-speed integral imaging in the visualization and detection of underwater dynamic events, which can be useful in underwater exploration and monitoring. 
    more » « less
  4. In this paper, we propose a procedure to analyze lensless single random phase encoding (SRPE) systems to assess their robustness to variations in image sensor pixel size as the input signal frequency is varied. We use wave propagation to estimate the maximum pixel size to capture lensless SRPE intensity patterns such that an input signal frequency can be captured accurately. Lensless SRPE systems are contrived by placing a diffuser in front of an image sensor such that the optical field coming from an object can be modulated before its intensity signature is captured at the image sensor. Since diffuser surfaces contain very fine features, the captured intensity patterns always contain high spatial frequencies regardless of the input frequencies. Hence, a conventional Nyquist-criterion-based treatment of this problem would not give us a meaningful characterization. We propose a theoretical estimate on the upper limit of the image sensor pixel size such that the variations in the input signal are adequately captured in the sensor pixels. A numerical simulation of lensless SRPE systems using angular spectrum propagation and mutual information verifies our theoretical analysis. The simulation estimate of the sampling criterion matches very closely with our proposed theoretical estimate. We provide a closed-form estimate for the maximum sensor pixel size as a function of input frequency and system parameters such that an input signal frequency can be captured accurately, making it possible to optimize general-purpose SRPE systems. Our results show that lensless SRPE systems have a much greater robustness to sensor pixel size compared with lens based systems, which makes SRPE useful for exotic imagers when pixel size is large. To the best of our knowledge, this is the first report to investigate sampling of lensless SRPE systems as a function of input image frequency and physical parameters of the system to estimate the maximum image sensor pixel size. 
    more » « less
  5. Poor access to eye care is a major global challenge that could be ameliorated by low-cost, portable, and easy-to-use diagnostic technologies. Diffuser-based imaging has the potential to enable inexpensive, compact optical systems that can reconstruct a focused image of an object over a range of defocus errors. Here, we present a diffuser-based computational funduscope that reconstructs important clinical features of a model eye. Compared to existing diffuser-imager architectures, our system features an infinite-conjugate design by relaying the ocular lens onto the diffuser. This offers shift-invariance across a wide field-of-view (FOV) and an invariant magnification across an extended depth range. Experimentally, we demonstrate fundus image reconstruction over a 33°FOV and robustness to ±4D refractive error using a constant point-spread-function. Combined with diffuser-based wavefront sensing, this technology could enable combined ocular aberrometry and funduscopic screening through a single diffuser sensor. 
    more » « less