Title: First on-sky interference fringes at 810 nm with the CHARA array using servo controlled hectometric outdoor fibre links
ABSTRACT In the framework of the ALOHA (Astronomical Light Optical Hybrid Analysis) project, we have implemented a fibre-linked interferometer connecting two telescopes of the CHARA (Center for High Angular Resolution Astronomy) array to the recombination beam facility using servo controlled hectometric outdoor fibres (240 m). During two consecutive nights, on-sky fringes at 810 nm were recorded on the star Vega (mag 0), with servo control of the fibre lengths. The optical path difference was set close to zero using internal fringes found before the on-sky observations. The repeatability of the delay line position offset between internal and on-sky fringes was less than 0.2 mm. The efficiency of the servo control systems has been demonstrated, leading to an enhancement of the signal-to-noise ratio from 68.9 with the servo off to 91.6 with the servo on. This result is a cornerstone for the ALOHA project goal of interferometry at 3.5 $$\mu$$m and a seminal step for the future kilometric infrared fibre-linked interferometer at CHARA.  more » « less
Award ID(s):
2034336 2407956
PAR ID:
10559451
Author(s) / Creator(s):
; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; more » ; « less
Publisher / Repository:
Oxford University Press
Date Published:
Journal Name:
Monthly Notices of the Royal Astronomical Society
Volume:
536
Issue:
1
ISSN:
0035-8711
Format(s):
Medium: X Size: p. 266-273
Size(s):
p. 266-273
Sponsoring Org:
National Science Foundation
More Like this
  1. null (Ed.)
    ABSTRACT In the framework of the Astronomical Light Optical Hybrid Analysis (ALOHA) laboratory mid-infrared (MIR) up-conversion fibred interferometer in the L band, we report on the influence of the input-stage architecture. Using an amplitude division set-up in the visible or near-infrared is a straightforward choice in most cases. In the MIR context, the results are slightly different and we show that a wavefront division set-up is needed. These in-laboratory principle experiments allow us to measure a reliable 88 per cent instrumental contrast with high flux and to obtain fringes from faint sources at 3.5 μm with a spectral bandwith of 37 nm converted to 817 nm. An equivalent limiting L-band magnitude around 3.9, equivalent to 3.0 fW nm−1, could be demonstrated on 1 m class telescopes. This opens the possibility of planning future on-sky tests at the Center for High Angular Resolution Astronomy (CHARA) array and of predicting the performance attained. 
    more » « less
  2. Abstract Though the time-domain millimeter sky is yet to be well characterized, the scarcity of millimeter observing resources in the world at present hampers progress toward it. In efforts to bolster the exploration of millimeter transients, we present the Stokes Polarization Radio Interferometer for Time-Domain Experiments (SPRITEly). Located at the Owens Valley Radio Observatory, SPRITEly is currently deployed as a two-element short-baseline 90 GHz interferometer uniquely focused on monitoring bright variable millimeter-continuum sources. We leverage two existing 10.4 m antennas and their existing receiver systems to begin, but we make significant upgrades to the back-end system during the commissioning process. With the ability to achieve rms noise of a few mJy, we plan to monitor known variable sources along with new nearby transients detected from optical surveys at high cadence, with the goal of producing well-sampled light curves. Interpreting these data in conjunction with multiwavelength observations stands to provide insight into the physical properties of the sources that produce transient millimeter emission. We present commissioning and early-science observations that demonstrate the performance of the instrument, including observations of the flaring BL Lac object S2 0109+22 and a periastron passage of the binary T Tauri system DQ Tau. 
    more » « less
  3. Mérand, Antoine; Sallum, Stephanie; Sanchez-Bermudez, Joel (Ed.)
    The Center for High Angular Resolution Astronomy (CHARA) Array is a six-element interferometer with baselines ranging from 34 to 331 m. Three new beam combiners are entering operation: MYSTIC is a 6-telescope combiner for K-band; SPICA is a 6-telescope combiner for the visible R-band; and SILMARIL is a 3-telescope combiner for high sensitivity in H and K-bands. A seventh, portable telescope will use fiber optics for beam transport and will increase the baselines to 1 km. Observing time is available through a program funded by NSF. The programs are solicited and peer-reviewed by NSF’s National Optical Infrared Astronomy Research Laboratory. The open community access has significantly expanded the range of astronomical investigations of stars and their environments. Here we summarize the scientific work and the on-going technical advances of the CHARA Array. 
    more » « less
  4. Miles, Janet; Bergstrand, Sten; Mana, Giovanni; White, Rod (Ed.)
    Abstract Current gravitational wave observatories rely onPhoton Calibrators(Pcals) that use laser radiation pressure to generate displacement fiducials used to calibrate detector output signals. Reducing calibration uncertainty enables optimal extraction of astrophysical information such as source distance and sky position from detected signals. For the ongoing O4 observation run that started on May 24, 2023, the global gravitational wave detector network is employing a new calibration scheme with transfer standards calibrated at both the National Institute of Standards and Technology (NIST) and the Physikalisch-Technische Bundesanstalt (PTB). These transfer standards will circulate between the observatories and the metrology institutes to provide laser power calibration traceable to the International System of Units (SI) and enable assessment and reduction of relative calibration errors for the observatory network. The Laser Interferometer Gravitational-Wave Observatory (LIGO) project and the Virgo project are currently participating in the new calibration scheme. The Large-scale Cryogenic Gravitational-wave Telescope project (KAGRA) is expected to join in 2024, with the LIGO Aundha Observatory (LAO) in India joining later. Before implementing this new scheme, a NIST-PTB bilateral comparison was conducted. The results of this comparison, with significantly lower uncertainty than previous studies, are reported. We also describe the transfer of power sensor calibration, including detailed uncertainty estimates, from the transfer standards calibrated by NIST and PTB to the sensors operating continuously at the interferometer end stations. Finally, we discuss the ongoing calibration of Pcal-induced displacement fiducials for the O4 observing run. Achieved combined standard uncertainty levels as low as 0.3 % facilitate calibrating the interferometer output signals with sub-percent accuracy. 
    more » « less
  5. This paper presents a novel noncontact measurement and inspection method based on knife-edge diffraction theory for corrosive wear propagation monitoring at a sharp edge. The degree of corrosion on the sharp edge was quantitatively traced in process by knife-edge interferometry (KEI). The measurement system consists of a laser diode, an avalanche photodiode, and a linear stage for scanning. KEI utilizes the interferometric fringes projected on the measurement plane when the light is incident on a sharp edge. The corrosion propagation on sharp edges was characterized by analyzing the difference in the two interferometric fringes obtained from the control and measurement groups. By using the cross-correlation algorithm, the corrosion conditions on sharp edges were quantitatively quantified into two factors: lag and similarity for edge loss and edge roughness, respectively. The KEI sensor noise level was estimated at 0.03% in full scale. The computational approach to knife-edge diffraction was validated by experimental validation, and the computational error was evaluated at less than 1%. Two sets of razor blades for measurement and control groups were used. As a result, the lag will be increased at an edge loss ratio of 1.007/µm due to the corrosive wear, while the similarity will be decreased at a ratio of 5.4 ×<#comment/> 10 −<#comment/> 4 / µ<#comment/> m with respect to edge roughness change. Experimental results showed a good agreement with computational results. 