skip to main content
US FlagAn official website of the United States government
dot gov icon
Official websites use .gov
A .gov website belongs to an official government organization in the United States.
https lock icon
Secure .gov websites use HTTPS
A lock ( lock ) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.


Title: Asymmetric sample shapes complicate planar biaxial testing assumptions by intensifying shear strains and stresses
Planar biaxial testing offers a physiologically relevant approach for mechanically characterizing thin deformable soft tissues, but often relies on erroneous assumptions of uniform strain fields and negligible shear strains and forces. In addition to the complex mechanical behavior exhibited by soft tissues, constraints on sample size, geometry, and aspect ratio often restrict sample shape and symmetry. Using simple PDMS gels, we explored the unknown and unquantified effects of sample shape asymmetry on planar biaxial testing results, including shear strain magnitudes, shear forces measured at the sample’s boundary, and the homogeneity of strains experienced at the center of each sample. We used a combination of finite element modeling and experimental validation to examine PDMS gels of varying levels of asymmetry, allowing us to identify effects of sample shape without confounding factors introduced by the nonlinear, spatially variable, and anisotropic properties of soft tissues. Both biaxial simulations and experiments, which showed strong agreement, revealed that sample shape asymmetry led to significantly larger shear strains, shear forces, and overestimation of principal stresses. Excluding these shear forces resulted in an underestimation of shear moduli during inverse mechanical characterizations. Even in the simplest of deformable biomaterials, sample shape asymmetry should be avoided as it can induce drastic increases in shear strains and shear forces, invalidating traditional planar biaxial testing analyses. Alternatively, sample shape asymmetry may be exploited to generate more robust estimates of constitutive parameters in more complex materials, which could lead to a refined understanding and inference of mechanical behavior.  more » « less
Award ID(s):
2030173
PAR ID:
10562743
Author(s) / Creator(s):
; ;
Publisher / Repository:
Elsevier
Date Published:
Journal Name:
Journal of the Mechanical Behavior of Biomedical Materials
Volume:
161
Issue:
C
ISSN:
1751-6161
Page Range / eLocation ID:
106795
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. Abstract Soft biological tissues often function as highly deformable membranes in vivo and exhibit impressive mechanical behavior effectively characterized by planar biaxial testing. The Generalized Anisotropic Inverse Mechanics (GAIM) method links full-field deformations and boundary forces from mechanical testing to quantify material properties of soft, anisotropic, heterogeneous tissues. In this study, we introduced an orthotropic constraint to GAIM to improve the quality and physical significance of its mechanical characterizations. We evaluated the updated GAIM method using simulated and experimental biaxial testing datasets obtained from soft tissue analogs (PDMS and TissueMend) with well-defined mechanical properties. GAIM produced stiffnesses (first Kelvin moduli, K1) that agreed well with previously published Young's moduli of PDMS samples. It also matched the stiffness moduli determined via uniaxial testing for TissueMend, a collagen-rich patch intended for tendon repair. We then conducted the first biaxial testing of TissueMend and confirmed that the sample was mechanically anisotropic via a relative anisotropy metric produced by GAIM. Next, we demonstrated the benefits of full-field laser micrometry in distinguishing between spatial variations in thickness and stiffness. Finally, we conducted an analysis to verify that results were independent of partitioning scheme. The success of the newly implemented constraints on GAIM suggests notable potential for applying this tool to soft tissues, particularly following the onset of pathologies that induce mechanical and structural heterogeneities. 
    more » « less
  2. ABSTRACT Soft materials with unique nanostructures such as lamellar, hexagonal, and cubic morphologies can replicate complex structures that have potential in various fields, including biomedical and industrial applications. However, a key challenge in advancing the broader applications of 3D printing for these nanostructured soft materials is insufficient mechanical properties that hinder their printability and compromise structural stability in the final product. In this study, the suitability of a fatty acid‐based lamellar gel is evaluated for direct extrusion‐based 3D printing. The lamellar gel with varying water content is integrated with a photocurable hydrogel to preserve the shape and stability of the final prints. Complex 2D and 3D design patterns are used to assess extrusion behavior, structural stability, and print precision under varying pressures. Small‐angle X‐ray Scattering (SAXS) measurements reveal the formation of lamellar nanostructures and confirm their retention after photocuring in various gels. Rheological analysis confirms that these gels exhibit key properties suitable for extrusion‐based 3D printing, such as shear‐thinning behavior. Additionally, tensile testing is conducted to evaluate the mechanical properties across cured print samples. This study underscores the potential of nanostructured gels as a robust and versatile platform, facilitating the development of materials engineered for various applications. 
    more » « less
  3. Objective: Adherent cell behavior is influ- enced by a complex interplay of factors, including chemical and mechanical signals. In vitro experiments that mimic the mechanical environment experienced by cells in vivo are crucial for understanding cellular behavior and the progression of disease. In this study, we developed and validated a low-cost pneumatically-controlled cell stretcher with independent control of strain in two directions of a membrane, enabling unequal biaxial stretching and real- time microscopy during actuation. Methods: The stretch- ing was achieved by two independent pneumatic channels controlled by electrical signals. We used finite element simulations to compute the membrane’s strain field and particle tracking algorithms based on image processing techniques to validate the strain fields and measure the cell orientation and morphology. Results: The device can supply uniaxial, equibiaxial, and unequal biaxial stretching up to 15% strain in each direction at a frequency of 1Hz, with a strain measurement error of less than 1%. Through live cell imaging, we determined that distinct stretching patterns elicited differing responses and alterations in cell orientation and morphology, particularly in terms of cell length and area. Conclusion: The device successfully pro- vides a large, uniform, and variable strain field for cell experiments, while also enabling real-time, live cell imag- ing. Significance: This scalable, low-cost platform provides mechanical stimulation to cell cultures by independently controlling strains in two directions. This could contribute to a deeper understanding of cellular response to bio- realistic strains and could be useful for future in vitro drug testing platforms. 
    more » « less
  4. This paper presents a recent investigation into the electromechanical behavior of thermally reduced graphene oxide (rGO) as a strain sensor undergoing repeated large mechanical strains up to 20.72%, with electrical signal output measurement in multiple directions relative to the applied strain. Strain is one the most basic and most common stimuli sensed. rGO can be synthesized from abundant materials, can survive exposure to large strains (up to 20.72%), can be synthesized directly on structures with relative ease, and provides high sensitivity, with gauge factors up to 200 regularly reported. In this investigation, a suspension of graphene oxide flakes was deposited onto Polydimethylsiloxane (PDMS) substrates and thermally reduced to create macroscopic rGO-strain sensors. Electrical resistance parallel to the direction of applied tension (x^) demonstrated linear behavior (similar to the piezoresistive behavior of solid materials under strain) up to strains around 7.5%, beyond which nonlinear resistive behavior (similar to percolative electrical behavior) was observed. Cyclic tensile testing results suggested that some residual micro-cracks remained in place after relaxation from the first cycle of tensile loading. A linear fit across the range of strains investigated produced a gauge factor of 91.50(Ω/Ω)/(m/m), though it was observed that the behavior at high strains was clearly nonlinear. Hysteresis testing showed high consistency in the electromechanical response of the sensor between loading and unloading within cycles as well as increased consistency in the pattern of the response between different cycles starting from cycle 2. 
    more » « less
  5. Studies from the past two decades have demonstrated convincingly that cells are able to sense the mechanical properties of their surroundings. Cells make major decisions in response to this mechanosensation, including decisions regarding cell migration, proliferation, survival, and differentiation. The vast majority of these studies have focused on the cellular mechanoresponse to changing substrate stiffness (or elastic modulus) and have been conducted on purely elastic substrates. In contrast, most soft tissues in the human body exhibit viscoelastic behavior; that is, they generate responsive force proportional to both the magnitude and rate of strain. While several recent studies have demonstrated that viscous effects of an underlying substrate affect cellular mechanoresponse, there is not a straightforward experimental method to probe this, particularly for investigators with little background in biomaterial fabrication. In the current work, we demonstrate that polymers comprised of differing polydimethylsiloxane (PDMS) formulations can be generated that allow for control over both the strain-dependent storage modulus and the strain rate-dependent loss modulus. These substrates requires no background in biomaterial fabrication to fabricate, are shelf-stable, and exhibit repeatable mechanical properties. Here we demonstrate that these substrates are biocompatible and exhibit similar protein adsorption characteristics regardless of mechanical properties. Finally, we develop a set of empirical equations that predicts the storage and loss modulus for a given blend of PDMS formulations, allowing users to tailor substrate mechanical properties to their specific needs. 
    more » « less