skip to main content
US FlagAn official website of the United States government
dot gov icon
Official websites use .gov
A .gov website belongs to an official government organization in the United States.
https lock icon
Secure .gov websites use HTTPS
A lock ( lock ) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.


Title: Phase 1: Pivoting Mass Ply Panel (MPP) Wall and Buckling-Restrained Boundary (BRB) Elements:Subtitle
A lateral force resisting system (LFRS) comprised of one eight-foot-wide Mass Ply Panel (MPP) with Buckling-Restrained Braces (BRBs) was attached to the building frame and tested following a cyclic quasi-static loading protocol up to 4% roof drift ratio. This system was designed to pivot about a pinned base, allowing the wall to rotate with minimal flexural restraint, thereby distributing drift demands more uniformly across the building height and reducing crushing damage at the wall base. Under first-mode loading, the system exhibited stable hysteretic behavior with a nearly uniform story drift profile, while second-mode loading revealed near-linear behavior with high stiffness. Experimental results provide valuable insights into the behavior of mass timber seismic lateral force-resisting systems and can be reused to develop and validate design guidelines for their broader implementation in seismic regions.  more » « less
Award ID(s):
2120683
PAR ID:
10571022
Author(s) / Creator(s):
; ; ; ; ; ;
Publisher / Repository:
Designsafe-CI
Date Published:
Subject(s) / Keyword(s):
quasi-static cyclic loading MPP VLT mass timber BRB UFP self-centering rocking wall lateral system seismic performance
Format(s):
Medium: X
Location:
Oregon State University
Institution:
AA “Red” Emmerson Advanced Wood Product Lab
Sponsoring Org:
National Science Foundation
More Like this
  1. Steel energy dissipators can be combined with mass timber in integrated seismic lateral force–resisting systems to achieve designs with enhanced seismic performance and sustainability benefits. Examples of such integration include the use of mass timber post-tensioned rocking walls equipped with steel energy dissipation devices. This study proposes a solution using buckling-restrained boundary elements (BRBs) with mass timber walls detailed to pivot about a pinned base. This design allows the walls to rotate with minimal flexural restraint, distributing drift demands more uniformly with building height and reducing crushing damage at the wall base. Experimental quasi-static cyclic tests and numerical simulations were used to characterize the first- and higher-mode behavior of a full-scale three-story building featuring a mass timber gravity system and the proposed mass timber-BRB system. Under first-mode loading, the specimen reached 4% roof drift ratio with stable hysteretic behavior and a nearly uniform story drift profile. While residual drifts were nonnegligible due to the lack of self-centering, analytical estimates indicate realignment is likely feasible at the design earthquake level. Under second-mode loading, the specimen exhibited near-linear behavior with high stiffness. Experimental results were corroborated with numerical simulations for the isolated gravity frame, first-mode-like, and second-mode-like loading protocols. It is expected that results from this study will facilitate greater use of mass timber seismic lateral force–resisting systems. 
    more » « less
  2. Mass timber products are gaining popularity in North America as an alternative to traditional construction materials as part of both the gravity and lateral force-resisting system. However, several knowledge gaps still exist in terms of their expected seismic performance and plausible hybridizations with other materials, e.g. steel energy dissipators. This research explores the potential use of wall spine systems consisting of mass ply panels (MPP) and steel buckling-restrained braces (BRBs) as energy dissipators. The proposed BRB-MPP spine assembly makes up the lateral force-resisting system of a three-story mass-timber building segment that will be tested under cyclic quasi-static loading at Oregon State University. The proposed design methodology follows displacement-based design principles to determine the minimum required stiffness to limit inelastic story drift ratios at the design earthquake level. The MPP spine and BRB-to-MPP connections were capacity designed to resist forces transferred by the BRBs at roof drift ratios beyond the risk-targeted Maximum Considered Earthquake (MCER). This design solution provides an interesting alternative for the design of modern mass timber buildings. The results obtained in the experimental campaign will be used to validate the design methodology and the behavior of the innovative structural system. 
    more » « less
  3. A lateral force resisting system (LFRS) comprised of two coupled four foot wide Veneer Laminated Timber (VLT) panels with U-shaped Flexural Plates (UFPs) and vertical post-tensioning was attached to the building frame and tested following a cyclic quasi-static loading protocol up to 4% roof drift ratio. 
    more » « less
  4. null (Ed.)
    Drywall partition walls are susceptible to damage at low-level drifts, and hence reducing such damage is key to achieving seismic resiliency in buildings. Prior tests on drywall partition walls have shown that slip track connection detailing leads to better performance than other detailing, such as fully-fixed connections. However, in all prior testing, partition wall performance was evaluated using a unidirectional loading protocol (either in-plane or out-of-plane) or in shake table testing. Moreover, all details are susceptible to considerable damage to wall intersections. Two phases of the test have been performed at the Natural Hazards Engineering Research Infrastructure (NHERI) Lehigh Equipment Facility to develop improved details of drywall partition walls under bidirectional loading. The partition walls were tested alongside a cross-laminated timber (CLT) post-tensioned rocking wall subassembly, wherein the CLT system is under development as a resilient lateral system for tall timber buildings. In the Phase 1, the slip behavior of conventional slip-track detailing was compared to telescoping detailing (track-within-a-track deflection assembly). In the Phase 2, two details for reducing the wall intersection damage were evaluated on traditional slip-track C-shaped walls. First, a corner gap detail was tested. This detail incorporates a gap through the wall intersection to reduce the collision damage at two intersecting walls. Second, a distributed gap detail was tested. In this approach, the aim was to reduce damage by using more frequent control joints through the length of the wall. All walls were tested under a bidirectional loading protocol with three sub-cycles: in-plane, a bi-directional hexagonal load path, and a bi-directional hexagonal load path with an increase in the out-of-plane drift. This loading protocol allows for studying the bidirectional behavior of walls and evaluating the effect of out-of-plane drift on the partition wall resisting force. In the Phase 1, the telescoping detailing performed better than conventional slip track detailing because it eliminated damage to the framing. In Phase 2, the distributed gap detailing delayed damage to about 1% story drift. For the corner gap detailing, the sacrificial corner bead detached at low drifts, but the wall itself was damage-free until 2.5% drift. Bidirectional loading was found to have an insignificant influence on the in-plane resistance of the walls, and the overall resistance of the walls was trivial compared to the CLT rocking. 
    more » « less
  5. null (Ed.)
    Nonlinear time history analyses were conducted for 5-story and 12-story prototype buildings that used post-tensioned cross-laminated timber rocking walls coupled with U-shaped flexural plates (UFPs) as the lateral force resisting system. The building models were subjected to 22 far-field and 28 near-fault ground motions, with and without directivity effects, scaled to the design earthquake and maximum considered earthquake for Seattle, with ASCE Site Class D. The buildings were designed to performance objectives that limited structural damage to crushing at the wall toes and nonlinear deformation in the UFPs, while ensuring code-based interstory drift requirements were satisfied and the post-tensioned rods remained linear. The walls of the 12-story building had a second rocking joint at midheight to reduce flexural demands in the lower stories and interstory drift in the upper stories. The interstory drift, in-plane wall shear and overturning moment, UFP deformation, and extent of wall toe crushing is summarized for each building. Near-fault ground motions with directivity effects resulted in the largest demands for the 5-story building, while the midheight rocking joint diminished the influence of ground motion directivity effects in the 12-story building. Results for both buildings confirmed that UFPs located higher from the base of the walls dissipated more energy compared to UFPs closer to the base. 
    more » « less