Title: Deployment and evaluation of an NH4+/H3O+ reagent ion switching chemical ionization mass spectrometer for the detection of reduced and oxygenated gas-phase organic compounds
Reactive organic carbon (ROC) is diverse in its speciation, functionalization, and volatility, with varying implications for ozone production and secondary organic aerosol formation and growth. Chemical ionization mass spectrometry (CIMS) approaches can provide in situ ROC observations, and the CIMS reagent ion controls the detectable ROC species. To expand the range of detectable ROC, we describe a method for switching between the reagent ions NH4+ and H3O+ in a Vocus chemical ionization time-of-flight mass spectrometer (Vocus-CI-ToFMS). We describe optimization of ion–molecule reactor conditions for both reagent ions, at the same temperature, and compare the ability of NH4+ and H3O+ to detect a variety of volatile organic compounds (VOCs) and semi-volatile and intermediate-volatility organic compounds (SVOCs and IVOCs), including oxygenates and organic sulfur compounds. Sensitivities are comparable to other similar instruments (up to ∼5 counts /s /pptv), with detection limits on the order of 1–10 s of pptv (1 s integration time). We report a method for characterizing and filtering periods of hysteresis following each reagent ion switch and compare use of reagent ions, persistent ambient ions, and a deuterated internal standard for diagnosing this hysteresis. We deploy NH4+/H3O+ reagent ion switching in a rural pine forest in central Colorado, US, and use our ambient measurements to compare the capabilities of NH4+ and H3O+ in the same instrument, without interferences from variation in instrument and inlet designs. We find that H3O+ optimally detects reduced ROC species with high volatility, while NH4+ improves detection of functionalized ROC compounds, including organic nitrates and oxygenated SVOCs and IVOCs that are readily fragmented by H3O+.  more » « less
Award ID(s):
2211153
PAR ID:
10592617
Author(s) / Creator(s):
;
Publisher / Repository:
Copernicus
Date Published:
Journal Name:
Atmospheric Measurement Techniques
Volume:
18
Issue:
1
ISSN:
1867-8548
Page Range / eLocation ID:
17 to 35
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. null (Ed.)
    Abstract. The molecular composition and volatility of gaseous organiccompounds were investigated during April–July 2019 at the Station forMeasuring Ecosystem – Atmosphere Relations (SMEAR) II situated in a borealforest in Hyytiälä, southern Finland. In order to obtain a morecomplete picture and full understanding of the molecular composition andvolatility of ambient gaseous organic compounds (from volatile organiccompounds, VOCs, to highly oxygenated organic molecules, HOMs), twodifferent instruments were used. A Vocus proton-transfer-reactiontime-of-flight mass spectrometer (Vocus PTR-ToF; hereafter Vocus) wasdeployed to measure VOCs and less oxygenated VOCs (i.e., OVOCs). Inaddition, a multi-scheme chemical ionization inlet coupled to an atmosphericpressure interface time-of-flight mass spectrometer (MION API-ToF) was usedto detect less oxygenated VOCs (using Br− as the reagent ion; hereafterMION-Br) and more oxygenated VOCs (including HOMs; using NO3- asthe reagent ion; hereafter MION-NO3). The comparison among differentmeasurement techniques revealed that the highest elemental oxygen-to-carbonratios (O : C) of organic compounds were observed by the MION-NO3 (0.9 ± 0.1, average ± 1 standard deviation), followed by the MION-Br(0.8 ± 0.1); lowest O : C ratios were observed by Vocus (0.2 ± 0.1). Diurnal patternsof the measured organic compounds were found to vary among differentmeasurement techniques, even for compounds with the same molecular formula,suggesting contributions of different isomers detected by the differenttechniques and/or fragmentation from different parent compounds inside theinstruments. Based on the complementary molecular information obtained fromVocus, MION-Br, and MION-NO3, a more complete picture of the bulkvolatility of all measured organic compounds in this boreal forest wasobtained. As expected, the VOC class was the most abundant (about 53.2 %), followed by intermediate-volatility organic compounds (IVOCs, about45.9 %). Although condensable organic compounds (low-volatility organiccompounds, LVOCs; extremely low volatility organic compounds, ELVOCs; andultralow-volatility organic compounds, ULVOCs) only comprised about 0.2 %of the total gaseous organic compounds, they play an important role in newparticle formation as shown in previous studies in this boreal forest. Ourstudy shows the full characterization of the gaseous organic compounds inthe boreal forest and the advantages of combining Vocus and MION API-ToF formeasuring ambient organic compounds with different oxidation extents (fromVOCs to HOMs). The results therefore provide a more comprehensiveunderstanding of the molecular composition and volatility of atmosphericorganic compounds as well as new insights into interpreting ambientmeasurements or testing/improving parameterizations in transport and climatemodels. 
    more » « less
  2. ABSTRACT: Isoprene, the most abundant nonmethane volatile organic compound in the atmosphere, undergoes photochemical reactions with hydroxyl radical (•OH), a major sink for isoprene, leading to the formation of secondary organic aerosol (SOA). Using a Vocus Chemical Ionization Mass Spectrometer with ammonium-adduct ions (Vocus NH4+ CIMS), this study used the positive ion mode to quantify the yields and time-dependent reactiveuptake of oxidized volatile organic compounds (OVOCs) produced from •OH-initiated oxidation of isoprene under dry conditions. Molar gas-phase yields of key oxidation products were constrained using sensitivities derived from a voltage scan of the front and back end of the Vocus ion−molecule reactor region. Carefully designed chamber experiments measured uptake coefficients (γ) for key isoprene-derived oxidation products onto acidic sulfate particles. The γ values for both C5H10O3 isomers (IEPOX/ISOPOOH) and C5H8O4, another epoxy species from isoprene photo-oxidation, rapidly decreased as the SOA coating thickness increased, demonstrating a self-limiting effect. Despite ISOPOOH/IEPOX contributing around 80% to total reactive uptake, other oxidation products from isoprene photooxidation were estimated to contribute 20% of the total SOA formation. These findings highlight the importance for future models to consider the self-limiting effects of ISOPOOH/IEPOX and SOA formation through non-IEPOX pathways. 
    more » « less
  3. Abstract. A new ion source (IS) utilizing vacuum ultraviolet (VUV) light is developed and characterized for use with iodide–chemical ionization massspectrometers (I−-CIMS). The VUV-IS utilizes a compact krypton lamp that emits light at two wavelengths corresponding to energies of∼10.030 and 10.641 eV. The VUV light photoionizes either methyl iodide (ionization potential, IP = 9.54 ± 0.02 eV)or benzene (IP = 9.24378 ± 0.00007 eV) to form cations and photoelectrons. The electrons react with methyl iodide to formI−, which serves as the reagent ion for the CIMS. The VUV-IS is characterized by measuring the sensitivity of a quadrupole CIMS (Q-CIMS) toformic acid, molecular chlorine, and nitryl chloride under a variety of flow and pressure conditions. The sensitivity of the Q-CIMS, with theVUV-IS, reached up to ∼700 Hz pptv−1, with detection limits of less than 1 pptv for a 1 min integration period. Thereliability of the Q-CIMS with a VUV-IS is demonstrated with data from a month-long ground-based field campaign. The VUV-IS is further tested byoperation on a high-resolution time-of-flight CIMS (TOF-CIMS). Sensitivities greater than 25 Hz pptv−1 were obtained for formic acid andmolecular chlorine, which were similar to that obtained with a radioactive source. In addition, the mass spectra from sampling ambient air wascleaner with the VUV-IS on the TOF-CIMS compared to measurements using a radioactive source. These results demonstrate that the VUV lamp is a viablesubstitute for radioactive ion sources on I−-CIMS systems for most applications. In addition, initial tests demonstrate that the VUV-IS canbe extended to other reagent ions by the use of VUV absorbers with low IPs to serve as a source of photoelectrons for high IP electron attachers,such as SF6-. 
    more » « less
  4. Volatile chemical products (VCPs) and other non-combustion-related sourceshave become important for urban air quality, and bottom-up calculationsreport emissions of a variety of functionalized compounds that remainunderstudied and uncertain in emissions estimates. Using a new instrumentalconfiguration, we present online measurements of oxygenated organiccompounds in a US megacity over a 10 d wintertime sampling period, whenbiogenic sources and photochemistry were less active. Measurements wereconducted at a rooftop observatory in upper Manhattan, New York City, USAusing a Vocus chemical ionization time-of-flight mass spectrometer, withammonium (NH4+) as the reagent ion operating at 1 Hz. The range ofobservations spanned volatile, intermediate-volatility, and semi-volatileorganic compounds, with targeted analyses of ∼150 ions, whoselikely assignments included a range of functionalized compound classes suchas glycols, glycol ethers, acetates, acids, alcohols, acrylates, esters,ethanolamines, and ketones that are found in various consumer, commercial,and industrial products. Their concentrations varied as a function of winddirection, with enhancements over the highly populated areas of the Bronx,Manhattan, and parts of New Jersey, and included abundant concentrations ofacetates, acrylates, ethylene glycol, and other commonly used oxygenatedcompounds. The results provide top-down constraints on wintertime emissionsof these oxygenated and functionalized compounds, with ratios to commonanthropogenic marker compounds and comparisons of their relative abundancesto two regionally resolved emissions inventories used in urban air qualitymodels. 
    more » « less
  5. Abstract. Chemical ionization massspectrometry (CIMS) instruments routinely detect hundreds of oxidized organic compoundsin the atmosphere. A major limitation of these instruments is the uncertaintyin their sensitivity to many of the detected ions. We describe thedevelopment of a new high-resolution time-of-flight chemical ionization massspectrometer that operates in one of two ionization modes: using eitherammonium ion ligand-switching reactions such as for NH 4 + CIMS orproton transfer reactions such as for proton-transfer-reaction massspectrometer (PTR-MS). Switching between the modes can be done within 2 min.The NH 4 + CIMS mode of the new instrument has sensitivities of upto 67 000 dcps ppbv−1 (duty-cycle-corrected ion counts per second perpart per billion by volume) and detection limits between 1 and 60 pptv at2σ for a 1 s integration time for numerous oxygenated volatileorganic compounds. We present a mass spectrometric voltage scanning procedurebased on collision-induced dissociation that allows us to determine thestability of ammonium-organic ions detected by the NH 4 + CIMS instrument.Using this procedure, we can effectively constrain the sensitivity of theammonia chemical ionization mass spectrometer to a wide range of detectedoxidized volatile organic compounds for which no calibration standards exist.We demonstrate the application of this procedure by quantifying thecomposition of secondary organic aerosols in a series of laboratoryexperiments. 
    more » « less