This study addresses the influence of biaxial interaction of hysteretic restoring forces of base isolation system on wind-induced response of base-isolated tall buildings. Both buildings with and without eccentricity in center of resistance are considered. Response history analysis is carried out to characterize the coupled responses of a square-shaped base-isolated tall building. A comprehensive parameter study is presented which covers a wide range of yielding level, response ratio and correlation of alongwind and crosswind base displacements. The results demonstrate that the biaxial interaction leads to increase in low-frequency component and decrease in resonant component of lower inelastic base displacement. However, the increase of low-frequency component of base displacement does not affect the upper building response relative to base isolation system. As a result, the upper building response is reduced by the influence of biaxial interaction. The biaxal interaction also results in fast growth of time-varying mean alongwind base displacement. The increase of low-frequency component can be significant when the yielding level of higher response is significant and two translational base displacements are quite different in magnitude. The correlation of two translational base displacements enhances the influence of biaxial interaction. For the base-isolated building with eccentricity, the alongwind and crosswind base responses are closer in magnitudes thus are less influenced by the biaxial interaction.
more »
« less
This content will become publicly available on January 1, 2026
Analyzing the inelastic response of wind-excited steel tall buildings through a reduced-order model incorporating strength and stiffness degradation along with P-Delta effects
When wind-excited tall buildings undergo vibrations beyond their linear elastic range, it becomes imperative to account for both strength and stiffness degradation and P-Delta effects. This study investigates the influence of the degradation and P-Delta effects on the inelastic response of wind-excited tall buildings through a reduced-order building model, wherein the alongwind and crosswind building responses are presumed to be contributed by the fundamental modes. The backbone curves of the hysteretic relationships between the generalized restoring forces and displacements are developed through monotonic static modal pushover analysis utilizing a high-fidelity finite element building model with consideration of P-Delta effect. A cyclic modal pushover analysis is performed to ascertain the degradation of generalized building stiffness and strength in both translation directions, stemming from the deterioration of steel material in stiffness and strength. Subsequently, a biaxial hysteretic force model is employed to depict the hysteretic relationships between generalized forces and displacements, factoring in degradation and P-Delta effects. The inelastic response of a 60-story steel building subjected to both alongwind and crosswind load excitations is quantified through response history analysis to assess the accuracy of the reduced-order building model and to evaluate the influence of degradation of material strength and pre-yield stiffness and P-Delta effects on various responses.
more »
« less
- Award ID(s):
- 2153189
- PAR ID:
- 10612833
- Publisher / Repository:
- ELSEVIER
- Date Published:
- Journal Name:
- Engineering Structures
- Volume:
- 323
- Issue:
- PA
- ISSN:
- 0141-0296
- Page Range / eLocation ID:
- 119268
- Format(s):
- Medium: X
- Sponsoring Org:
- National Science Foundation
More Like this
-
-
As global urbanization accelerates, the construction of tall buildings has surged, becoming a defining feature of modern cityscapes. Tall buildings, while contributing to economic growth and urban development, face substantial risks from extreme wind events, such as hurricanes and downbursts. This study provides a comprehensive evaluation of the performance of tall building facades under severe wind conditions, with a focus on recent events that impacted the Gulf Coast of the United States, specifically in Houston, during May to July 2024, including a powerful derecho and Hurricane Beryl. Through extensive damage assessments of various tall buildings, this research highlights the different damages observed from these wind events, revealing critical vulnerabilities in tall building façades, particularly in relation to wind channeling effects in densely built urban areas. The observed damage patterns, including extensive glass breakage and façade failures, underscore the need for a reassessment of wind effects on tall buildings to better reflect the complex interactions between wind forces and urban environments. Additionally, by integrating real-world damage observations with wind tunnel simulations carried out at the NSF NHERI Wall of Wind Experimental Facility, this research offers valuable insights into the factors that may have influenced the observed damage. In this wind tunnel testing campaign, a series of aerodynamic testing of a tall building model under both atmospheric boundary layer and downburst winds were conducted. Additionally, interference effects are tested for both types of events. The preliminary findings have shown that downburst winds can have higher negative pressures compared to atmospheric boundary layer (ABL) which needs to be further studied including several downburst events to characterize the difference between both types of winds. Also, the results indicated the need to conduct a detailed interference study to compare ABL and downburst to properly include these effects for dense urban areas.more » « less
-
This paper reviews the state-of-the-art and –practice on various methodologies developed to control the wind-induced vibration of tall buildings. Tall buildings experience wind-induced vibration in the along- and across-wind directions depending on the wind direction, building shape, height, and structural properties. It is possible to control the wind response of buildings through passive, active, and semi-active systems. Damping systems, which are widely used to reduce the structural vibrations, are reviewed, and their performance in alleviating the building vibration is discussed. It was found that the application of conventional dampers needs to be reassessed to ensure their efficiency in dissipating the energy, especially caused by wind loads. Specific attention has been given to the aerodynamic modification of building shapes considering their effectiveness and high popularity within the wind engineering community. A comprehensive review of the existing wind tunnel experiment and Computational Fluid Dynamics (CFD) studies are conducted here to present the past and recent achievements on the response mitigation of tall buildings. A comparative study on the performance of different systems has been provided that can provide a commencing point for future studies. The existing challenges and their solutions are explained, and suggestions for future studies are proposed. It is expected that the information provided in this paper will facilitate further research in the area of wind-induced vibration mitigation approaches of tall buildings.more » « less
-
Abstract Use of cold‐formed steel (CFS) framing as load‐bearing system for gravity and lateral loads in buildings is becoming increasingly common in the North American construction industry, notably in high seismic regions where light‐weight construction is an attractive option. Buildings framed with closely spaced and repetitively placed CFS members can be detailed to develop lateral resistance using a variety of sheathing options. A relatively new option involves the use of steel sheet as sheathing. Steel sheet sheathed CFS shear walls offer high lateral strength and stiffness, and provide ductility courtesy of tension field action within the steel sheet. Despite their acceptance, gaps in the understanding of their behavior do exist, notably, behavior under dynamic loading, the contribution of nonstructural architectural finishes, and the behavior of wall‐lines: shear walls placed inline with gravity walls. To this end, a two‐phased experimental effort was undertaken to advance understanding of the lateral response of CFS‐framed wall‐line systems. Specifically, a suite of wall‐lines, detailed for mid‐rise buildings, were evaluated through simulated seismic loading imposed via shake table and quasi‐static cyclic tests. Damage to the wall‐lines was largely manifested in the form of damage to fastener connections used for attaching the sheathing and gypsum panels, and separation of exterior finish layer. This paper documents and quantifies the progressively incurred physical damage observed in the tested wall‐line assemblies, and correlates it with the evolution of dynamic characteristics and hysteretic energy dissipated across a spectrum of performance levels.more » « less
-
Mass timber panels are emerging as an innovative alternative for the design of elastic spines due to their high stiffness- and strength-to-weight ratio, among other factors. Recent research has shown that mass timber panels used in conjunction with steel energy dissipators are promising solutions for enhanced seismic performance. However, the available experimental data at the building scale is still minimal, which limits the understanding, adoption, and development of effective seismic design guidelines for these systems. This research addresses this gap through full-scale quasi-static cyclic testing of a three-story mass timber building. Lateral loads are transferred through Mass Ply Panel (MPP) diaphragms to an MPP spine with vertically-oriented unbonded steel buckling-restrained braces (BRBs) as energy dissipating boundary elements in the first story. The only elements designed to dissipate energy in the inelastic range are the BRBs. The building specimen achieved low-structural damage and enhanced-performance goals, being able to reach a 4% roof drift ratio with little loss of strength and stiffness. The proposed pivoting detail was effective in mitigating compressive damage at the wall toe. To support the experimental campaign and future design procedures, a high-fidelity numerical model of the building was developed using OpenSees.more » « less