Data center operators generally overprovision IT and cooling capacities to address unexpected utilization increases that can violate service quality commitments. This results in energy wastage. To reduce this wastage, we introduce HCP (Holistic Capacity Provisioner), a service latency aware management system for dynamically provisioning the server and cooling capacity. Short-term load prediction is used to adjust the online server capacity to concentrate the workload onto the smallest possible set of online servers. Idling servers are completely turned off based on a separate long-term utilization predictor. HCP targets data centers that use chilled air cooling and varies the cooling provided commensurately, using adjustable aperture tiles and speed control of the blower fans in the air handler. An HCP prototype supporting a server heterogeneity is evaluated with real-world workload traces/requests and realizes up to 32% total energy savings while limiting the 99th-percentile and average latency increases to at most 6.67% and 3.24%, respectively, against a baseline system where all servers are kept online.
more »
« less
EMPower: The Case for a Cloud Power Control Plane
Escalating application demand and the end of Dennard scaling have put energy management at the center of cloud operations. Because of the huge cost and long lead time of provisioning new data centers, operators want to squeeze as much use out of existing data centers as possible, often limited by power provisioning fixed at the time of construction. Workload demand spikes and the inherent variability of renewable energy, as well as increased power unreliability from extreme weather events and natural disasters, make the data center power management problem even more challenging. We believe it is time to build a power control plane to provide fine-grained observability and control over data center power to operators. Our goal is to help make data centers substantially more elastic with respect to dynamic changes in energy sources and application needs, while still providing good performance to applications. There are many use cases for cloud power control, including increased power oversubscription and use of green energy, resilience to power failures, large-scale power demand response, and improved energy efficiency.
more »
« less
- Award ID(s):
- 2104548
- PAR ID:
- 10625149
- Publisher / Repository:
- HotCarbon; ACM Energy Informatics Review
- Date Published:
- Format(s):
- Medium: X
- Sponsoring Org:
- National Science Foundation
More Like this
-
-
Adoption of renewable energy in power grids introduces stability challenges in regulating the operation frequency of the electricity grid. Thus, electrical grid operators call for provisioning of frequency regulation services from end-user customers, such as data centers, to help balance the power grid’s stability by dynamically adjusting their energy consumption based on the power grid’s need. As renewable energy adoption grows, the average reward price of frequency regulation services has become much higher than that of the electricity cost. Therefore, there is a great cost incentive for data centers to provide frequency regulation service. Many existing techniques modulating data center power result in significant performance slowdown or provide a low amount of frequency regulation provision. We present PowerMorph , a tight QoS-aware data center power-reshaping framework, which enables commodity servers to provide practical frequency regulation service. The key behind PowerMorph is using “complementary workload” as an additional knob to modulate server power, which provides high provision capacity while satisfying tight QoS constraints of latency-critical workloads. We achieve up to 58% improvement to TCO under common conditions, and in certain cases can even completely eliminate the data center electricity bill and provide a net profit.more » « less
-
null (Ed.)With the rapid development of the Internet of Things (IoT), computational workloads are gradually moving toward the internet edge for low latency. Due to significant workload fluctuations, edge data centers built in distributed locations suffer from resource underutilization and requires capacity underprovisioning to avoid wasting capital investment. The workload fluctuations, however, also make edge data centers more suitable for battery-assisted power management to counter the performance impact due to underprovisioning. In particular, the workload fluctuations allow the battery to be frequently recharged and made available for temporary capacity boosts. But, using batteries can overload the data center cooling system which is designed with a matching capacity of the power system. In this paper, we design a novel power management solution, DeepPM, that exploits the UPS battery and cold air inside the edge data center as energy storage to boost the performance. DeepPM uses deep reinforcement learning (DRL) to learn the data center thermal behavior online in a model-free manner and uses it on-the-fly to determine power allocation for optimum latency performance without overheating the data center. Our evaluation shows that DeepPM can improve latency performance by more than 50% compared to a power capping baseline while the server inlet temperature remains within safe operating limits (e.g., 32°C).more » « less
-
Power management in data centers is challenging because of fluctuating workloads and strict task completion time requirements. Recent resource provisioning systems, such as Borg and RC-Informed, pack tasks on servers to save power. However, current power optimization frameworks based on packing leave very little headroom for spikes, and the task completion times are compromised. In this paper, we design Goldilocks, a novel resource provisioning system for optimizing both power and task completion time by allocating tasks to servers in groups. Tasks hosted in containers are grouped together by running a graph partitioning algorithm. Containers communicating frequently are placed together, which improves the task completion times. We also leverage new findings on power consumption of modern- day servers to ensure that their utilizations are in a range where they are power-proportional. Both testbed implementation measurements and large-scale trace-driven simulations prove that Goldilocks outperforms all the previous works on data center power saving. Goldilocks saves power by 11.7%-26.2% depending on the workload, whereas the best of the implemented alternatives, Borg, saves 8.9%-22.8%. The energy per request for the Twitter content caching workload in Goldilocks is only 33% of RC-Informed. Finally, the best alternative in terms of task completion time, E-PVM, has 1.17-3.29 times higher task completion times than Goldilocks across different workloads.more » « less
-
Electricity bill constitutes a significant portion of operational costs for large scale data centers. Empowering data centers with on-site storages can reduce the electricity bill by shaping the energy procurement from deregulated electricity markets with real-time price fluctuations. This work focuses on designing energy procurement and storage management strategies to minimize the electricity bill of storage-assisted data centers. Designing such strategies is challenging since the net energy demand of the data center and electricity market prices are not known in advance, and the underlying problem is coupled over time due to evolution of the storage level. Using competitive ratio as the performance measure, we propose an online algorithm that determines the energy procurement and storage management strategies using a threshold based policy. Our algorithm achieves the optimal competitive ratio of as a function of the price fluctuation ratio. We validate the algorithm using data traces from electricity markets and data-center energy demands. The results show that our algorithm achieves close to the offline optimal performance and outperforms existing alternatives.%more » « less
An official website of the United States government