skip to main content
US FlagAn official website of the United States government
dot gov icon
Official websites use .gov
A .gov website belongs to an official government organization in the United States.
https lock icon
Secure .gov websites use HTTPS
A lock ( lock ) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.


This content will become publicly available on June 25, 2026

Title: Characterizing sample degradation from synchrotron based X-ray measurements of ultra-thin exfoliated flakes
It is undeniable that novel 2D devices and heterostructures will have a lasting impact on the advancement of future technologies. However, the inherent instability of many exfoliated van der Waals (vdW) materials is a well-known hurdle yet to be overcome. Thus, the sustained interest in exfoliated vdW materials underscores the importance of understanding the mechanisms of sample degradation to establish proactive protective measures. Here, the impact of prolonged synchrotron-based X-ray beam exposure on exfoliated flakes of two contemporary vdW materials, N i P S 3 and α - R u C l 3 , is explored using resonant inelastic X-ray scattering (RIXS) and total fluorescence yield X-ray absorption spectroscopy (XAS). In N i P S 3 , the resulting RIXS and XAS spectra show a suppression, then vanishing, of NiS6multiplet excitations coupled with an upward shift of the peak energy of the XAS as a function of X-ray dose. In α - R u C l 3 , the signs of beam damage from the RIXS spectra are less evident. However, the post-experiment characterization of both materials using Raman spectroscopy exhibits signals of an amorphous and disordered system compared to pristine flakes; in addition, energy-dispersive X-ray spectroscopy of N i P S 3 shows evidence of ligand vacancies. As synchrotron radiation is fast becoming a required probe to study 2D vdW materials, these findings lay the groundwork for the development of future protective measures for synchrotron-based prolonged X-ray beam exposure, as well as for X-ray free electron laser.  more » « less
Award ID(s):
2211334
PAR ID:
10628456
Author(s) / Creator(s):
; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ;
Publisher / Repository:
frontiers
Date Published:
Journal Name:
Frontiers in Electronic Materials
Volume:
5
ISSN:
2673-9895
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. BackgroundPersonalized hemodynamic models can accurately compute fractional flow reserve (FFR) from coronary angiograms and clinical measurements (FFR baseline ), but obtaining patient-specific data could be challenging and sometimes not feasible. Understanding which measurements need to be patient-tuned vs. patient-generalized would inform models with minimal inputs that could expedite data collection and simulation pipelines. AimsTo determine the minimum set of patient-specific inputs to compute FFR using invasive measurement of FFR (FFR invasive ) as gold standard. Materials and MethodsPersonalized coronary geometries ( N = 50 ) were derived from patient coronary angiograms. A computational fluid dynamics framework, FFR baseline , was parameterized with patient-specific inputs: coronary geometry, stenosis geometry, mean arterial pressure, cardiac output, heart rate, hematocrit, and distal pressure location. FFR baseline was validated against FFR invasive and used as the baseline to elucidate the impact of uncertainty on personalized inputs through global uncertainty analysis. FFR streamlined was created by only incorporating the most sensitive inputs and FFR semi-streamlined additionally included patient-specific distal location. ResultsFFR baseline was validated against FFR invasive via correlation ( r = 0.714 , p < 0.001 ), agreement (mean difference: 0.01 ± 0.09 ), and diagnostic performance (sensitivity: 89.5%, specificity: 93.6%, PPV: 89.5%, NPV: 93.6%, AUC: 0.95). FFR semi-streamlined provided identical diagnostic performance with FFR baseline . Compared to FFR baseline vs. FFR invasive , FFR streamlined vs. FFR invasive had decreased correlation ( r = 0.64 , p < 0.001 ), improved agreement (mean difference: 0.01 ± 0.08 ), and comparable diagnostic performance (sensitivity: 79.0%, specificity: 90.3%, PPV: 83.3%, NPV: 87.5%, AUC: 0.90). ConclusionStreamlined models could match the diagnostic performance of the baseline with a full gamut of patient-specific measurements. Capturing coronary hemodynamics depended most on accurate geometry reconstruction and cardiac output measurement. 
    more » « less
  2. Breath analysis enables rapid, noninvasive diagnostics, as well as long-term monitoring of human health, through the identification and quantification of exhaled biomarkers. Here, we demonstrate the remarkable capabilities of mid-infrared (mid-IR) cavity-enhanced direct-frequency comb spectroscopy (CE-DFCS) applied to breath analysis. We simultaneously detect and monitor as a function of time four breath biomarkers— C H 3 OH, C H 4 , H 2 O, and HDO—as well as illustrate the feasibility of detecting at least six more ( H 2 CO, C 2 H 6 , OCS, C 2 H 4 , C S 2 , and N H 3 ) without modifications to the experimental apparatus. We achieve ultrahigh detection sensitivity at the parts-per-trillion level. This is made possible by the combination of the broadband spectral coverage of a frequency comb, the high spectral resolution afforded by the individual comb teeth, and the sensitivity enhancement resulting from a high-finesse cavity. Exploiting recent advances in frequency comb, optical coating, and photodetector technologies, we can access a large variety of biomarkers with strong carbon–hydrogen-bond spectral signatures in the mid-IR. 
    more » « less
  3. Abstract Fe 3 + δ GeTe 2 (FGT) has proved to be an interesting van der Waals (vdW) ferromagnetic compound with a tunable Curie temperature ( T C ). However, the underlying mechanism for varying T C remains elusive. Here, we systematically investigate and compare low-temperature magnetic properties of single crystalline FGT samples that exhibit T C s ranging from 160 K to 205 K. Spin stiffness (D) and spin excitation gap (Δ) are extracted using Bloch’s theory for crystals with varying Fe content. Compared to Cr-based vdW ferromagnets, FGT compounds have higher spin stiffness values but lower spin wave excitation gaps. We discuss the implication of these relationships in Fe–Fe ion magnetic interactions in FGT unit cells. The itinerancy of magnetic electrons is measured and discussed under the Rhodes–Wohlfarth ratio (RWR) and the Takahashi theory. 
    more » « less
  4. Through laser-heated diamond anvil cell experiments, we synthesize a series of rubidium superhydrides and explore their properties with synchrotron x-ray powder diffraction and Raman spectroscopy measurements, combined with density functional theory calculations. Upon heating rubidium monohydride embedded in H 2 at a pressure of 18 GPa, we form RbH 9 I , which is stable upon decompression down to 8.7 GPa, the lowest stability pressure of any known superhydride. At 22 GPa, another polymorph, RbH 9 II is synthesised at high temperature. Unique to the Rb-H system among binary metal hydrides is that further compression does not promote the formation of polyhydrides with higher hydrogen content. Instead, heating above 87 GPa yields RbH 5 , which exhibits two polymorphs ( RbH 5 I and RbH 5 II ). All of the crystal structures comprise a complex network of quasimolecular H 2 units and H anions, with RbH 5 providing the first experimental evidence of linear H 3 anions. Published by the American Physical Society2025 
    more » « less
  5. We present the optical and structural characterization of films of T a 2 O 5 , S c 2 O 3 , and S c 2 O 3 doped T a 2 O 5 with a cation ratio around 0.1 grown by reactive sputtering. The addition of S c 2 O 3 as a dopant induces the formation of tantalum suboxide due to the “oxygen getter” property of scandium. The presence of tantalum suboxide greatly affects the optical properties of the coating, resulting in higher absorption loss at λ<#comment/> = 1064 n m . The refractive index and optical band gap of the mixed film do not correspond to those of a mixture of T a 2 O 5 and S c 2 O 3 , given the profound structural modifications induced by the dopant. 
    more » « less