This paper presents a mid-air haptic interface device enabled by a piezoelectric micromachined ultrasonic transducer (pMUT) array achieving an unprecedentedly high transmission pressure of 2900 Pa at a 15 mm distance for the first time. The structure is based on sputtered potassium sodium niobate (K,Na)NbO3 (KNN) thin film with a high piezoelectric coefficient (𝑒𝑒31 ~ 8-10 C/m2). A prototype KNN pMUT array composed of 15×15 dual-electrode circular-shape diaphragms exhibits a resonant frequency around 92.4 kHz. Testing results show a transmitting sensitivity of 120.8 Pa/cm2 per volt under only 12 Vp-p excitation at the natural focal point of 15 mm away, which is at least 3 times that of previously reported AlN pMUTs at a similar frequency. Furthermore, an instant non-contact haptic stimulation of wind-like sensation on human palms has been realized. As such, this work sheds light on a new class of pMUT array with high acoustic output pressure for human-machine interface applications, such as consumer electronics and AR/VR systems. 
                        more » 
                        « less   
                    
                            
                            IMPROVED PERFORMANCE OF PASSIVE LAYER-FREE CURVED PMUT ARRAY
                        
                    
    
            We have successfully demonstrated a novel, passive layer-free, curved piezoelectric micromachined ultrasound transducer (PMUT) array, using a sacrificial curved glass template and 30% scandium-doped aluminum nitride (Sc-AlN) as the active layer. The PMUTs were fabricated using a curved, suspended borosilicate glass template created via a chip-scale glass-blowing technique, onto which electrodes and the piezoelectric layer were deposited. The glass layer was thereafter selectively removed. We characterized the performance of a 13 × 13 curved PMUT (cPMUT) array using an electrical impedance analyzer, a Laser Doppler Vibrometer (LDV), and hydrophone pressure measurements. Our results reveal a device resonance frequency of approximately 1.8 MHz in air, with LDV analysis indicating a significantly enhanced low-frequency response of 1.68 nm/V—a fivefold improvement over conventional curved PMUTs with a passive layer. Additionally, acoustic characterization in water showed that this array generates an acoustic pressure of approximately 80 kPa at a 4.4 mm focal distance, with a beam width of 5 mm, and achieves a spatial peak pulse average intensity (ISPPA) of 216 mW/cm2 when driven off-resonance. Furthermore, we demonstrate 20-degree steering capability using our data acquisition system. These advancements highlight significant potential for enhancing the precision and efficacy of medical imaging and therapeutic applications, particularly in ultrasonic diagnostics and treatments. 
        more » 
        « less   
        
    
                            - Award ID(s):
- 2053591
- PAR ID:
- 10629023
- Editor(s):
- Chan, Jenna F; Rajaraman, Swaminathan
- Publisher / Repository:
- Proceeding of the Solid Sensors, Actuators and Microsystems Workshop 2024, Hilton Head
- Date Published:
- Subject(s) / Keyword(s):
- Ultrasound transducers array scandium-doped aluminum nitride chip-scale glass blowing curved glass structures piezoelectric micromachined ultrasound transducer (PMUT) curved PMUTs (cPMUT)
- Format(s):
- Medium: X
- Location:
- Hilton Head, SC
- Sponsoring Org:
- National Science Foundation
More Like this
- 
            
- 
            This paper presents a mid-air thermal interface enabled by a piezoelectric micromachined ultrasonic transducer (pMUT) array. The two-stage thermal actuating process consists of an ultrasound-transmission process via a pMUT array and an ultrasound-absorption process via porous fabric. The pMUT design employs sputtered potassium sodium niobate (K,Na)NbO3 (KNN) thin film with a high piezoelectric coefficient (d31 ~ 8-10 C/m2) as piezoelectric layer for enhanced acoustic pressure. Testing results show that the prototype pMUT array has a resonant frequency around 97.6 kHz, and it can generate 1970 Pa of focal pressure at 15 mm away under the 10.6 Vp-p excitation. As a result, fabric temperature in the central focal area can rise from 24.2℃ to 31.7℃ after 320 seconds with an average temperature variation rate of 0.023℃/s. Moreover, thermal sensations on the human palms have been realized by the heat conduction through the fabric-skin contact. As such, this work highlights the promising application of pMUT array with high acoustic pressure for human-machine interface, particularly mid-air thermal display.more » « less
- 
            This work reports a platform based on ultrasound for mid-air particle manipulations using a 2×2 piezoelectric micromachined ultrasonic transducer (pMUT) array. Three achievements have been demonstrated as compared to the state-of-art: (1) high SPL (sound pressure level) of 120 dB at a distance 12 mm away by an individual lithium-niobate pMUT; (2) a numerically simulated and experimentally demonstrated 2D focal point control scheme by adjusting the phase-delay of individual pMUTs; and (3) the experimental demonstration of moving a 0.7 mg foam plastic particle of 12 mm away in the mid-air by ~1.8 mm. As such, this work shows the potential for practical applications in the broad fields of non-contact actuations, including particle manipulations in microfluidics, touchless haptic sensations, … etc.more » « less
- 
            Langfelder, Giacomo (Ed.)In this letter, we report on a high-sensitivity whispering gallery mode (WGM) resonator-based air-coupled ultrasound sensor capable of detecting minute pressure variations across an ultrasound frequency spectrum of 0.6–3.5 MHz. The sensor comprises a microspherical glass shell of approximately 450 μm in radius and nonuniform shell thickness of 7–15 μm, which is optically coupled to a tunable laser for resonance excitation. The setup allows for the precise measurement of acoustic signals, benefiting from the high optical Q-factor of ∼2 million of the blown glass microspherical shells. A noise equivalent pressure as low as 40 μPa/ √Hz was obtained at 1.72-MHz ultrasound frequency. A very good correspondence between the simulated axisymmetric resonance frequencies measured using the WGM resonator and a 3D finite-element analysis model in COMSOL was established. The sensor showed an expected linear dependence on the drive voltage of the ultrasound transducer. The distortion of the microspherical shell under acoustic pressure was also independently confirmed using a laser Doppler vibrometer. The sensor’s capability to handle high-frequency ultrasonic waves with significantly better signal-to-noise ratio than conventional piezoelectric- or microphone-based systems is demonstrated, highlighting its suitability for advanced photoacoustic applications.more » « less
- 
            The receive sensitivity of lead zirconate titanate (PZT) piezoelectric micromachined ultrasound transducers (PMUTs) was improved by applying a DC bias during operation. The PMUT receive sensitivity is governed by the voltage piezoelectric coefficient, h31,f. With applied DC biases (up to 15 V) on a 2 μm PbZr0.52Ti0.48O3 film, e31,f increased 1.6 times, permittivity decreased by a factor of 0.6, and the voltage coefficient increased by ~2.5 times. For released PMUT devices, the ultrasound receive sensitivity improved by 2.5 times and the photoacoustic signal improved 1.9 times with 15 V applied DC bias. B-mode photoacoustic imaging experiments showed that with DC bias, the PMUT received clearer photoacoustic signals from pencil leads at 4.3 cm, compared to 3.7 cm without DC bias.more » « less