Space cooling constitutes >10% of worldwide electricity consumption and is anticipated to rise swiftly due to intensified heatwaves under emerging climate change. The escalating electricity demand for cooling services will challenge already stressed power grids, especially during peak times of demand. To address this, the adoption of demand response to adjust building energy use on the end-user side becomes increasingly important to adapt future smart buildings with rapidly growing renewable energy sources. However, existing demand response strategies predominantly explore sensible cooling energy as flexible building load while neglecting latent cooling energy, which constitutes significant portions of total energy use of buildings in humid climates. Hence, this paper aims to evaluate the demand response potential by adjusting latent cooling energy through ventilation control for typical medium commercial office buildings in four representative cities across different humid climate zones, i.e., Miami, Huston, Atlanta, and New York in the United States (US). As the first step, the sensible heat ratio, defined as sensible cooling load to total building load (involving both sensible and latent load), in different humid climates are calculated. Subsequently, the strategy to adjust building latent load through ventilation control (LLVC) is explored and implemented for demand response considering the balance of energy shifting, indoor air quality, and energy cost. Results reveal that adjusting building ventilation is capable of achieving 30%–40% Heating, Ventilation, and Air-conditioning (HVAC) cooling demand flexibility during HVAC operation while among this, the latent cooling energy contributes 56% ~ 66.4% to the overall demand flexibility. This work provides a feasible way to improve electricity grid flexibility in humid climates, emphasizing the significant role of adjusting latent cooling energy in building demand response.
more »
« less
This content will become publicly available on June 21, 2026
Energy performance analysis of a dedicated outdoor air system with a desiccant wheel through Julia-based modeling
While ventilation is crucial for ensuring indoor air quality and occupant health, introducing fresh air can lead to increased latent loads due to dehumidification, particularly, in humid climates. The Dedicated Outdoor Air System (DOAS) has gained attention for its ability to supply all fresh air while decoupling latent and sensible loads in buildings. Integrating a desiccant wheel (DW) into the DOAS further enhances its dehumidification performance compared to conventional cooling-based methods. This study proposes a modeling approach leveraging the Julia language and its equation-based acausal modeling framework to analyze the energy performance of DOAS systems, highlighting Julia’s potential in heating, ventilation, and air-conditioning (HVAC) applications. Specifically, we modeled two configurations of DW-based DOAS: one using an active DW and the other using a passive DW. The main modeling components include a desiccant wheel, a thermal network-based office room model considering sensible and latent loads, coils and local controllers. A simulation case study was then conducted to compare the energy performance of the two DOAS configurations over one week during the cooling season in Houston, TX. This study presents a preliminary workflow for HVAC modeling and optimization using a Julia-based symbolic modeling framework, highlighting its potential over conventional methods. The framework is extendable for a further high-fidelity modeling and advanced control analysis of DOAS, and other HVAC equipment and systems.
more »
« less
- Award ID(s):
- 2318720
- PAR ID:
- 10639218
- Publisher / Repository:
- ASHRAE
- Date Published:
- Format(s):
- Medium: X
- Sponsoring Org:
- National Science Foundation
More Like this
-
-
Controlling humidity in indoor plant environments is crucial to plant growth, but traditional dehumidification methods can be energy intensive. In this study, we evaluate the energy efficiency of a novel dehumidification concept that uses cold concentrated fertilizer solution as a liquid desiccant agent. This closes the water cycle by recovering water vapor for plant fertigation, and eliminates the need for energy-intensive desiccant regeneration. A theoretical transport model is used to conduct a parametric analysis of the specific energy performance of the system in response to desiccant temperature and other operating conditions. Specific energy of dehumidification is defined here as the ratio of the cooling load to the water vapor removal. Minimum specific energy results between 0.16-0.24 Wh/g are achieved at liquid desiccant temperatures between 7-14 °C. These results compare very favorably with other dehumidification technologies on the market, and satisfy new energy efficiency standards for indoor plant cultivation. The vapor flux associated with the minimum specific energy ranged from 1.2-1.6 g/m2/h. Controlling liquid desiccant temperature is shown to be critical to achieving high dehumidification rates at optimal specific energies. These encouraging results suggest that future research and development along this track can contribute to energy efficient greenhouse cultivation for sustainable food production.more » « less
-
As web-based AI applications are growing rapidly, server rooms face escalating computational demands, prompting enterprises to either upgrade their facilities or outsource to co-located sites. This growth strains conventional heating ventilation and air-conditioning (HVAC) systems, which struggle to handle the substantial thermal load, often resulting in hotspots. Liquid-to-air (L2A) coolant distribution units (CDUs) emerge as a solution, efficiently cooling servers by circulating liquid coolant through cooling loops (CLs) mounted on each server board. In this study, the performance of a 24-kW L2A CDU is evaluated across various scenarios, emphasizing cooling effect and stability. Experimental tests involve a rack with three thermal test vehicles (TTVs), monitoring both liquid coolant and air sides for analysis. Tests are conducted in a limited air-conditioned environment, resembling upgraded server rooms with conventional AC systems. The study also assesses the impact of high-power density cooling units on the server room environment, measuring noise, air velocity, and ambient temperature against ASHRAE standards for human comfort. Recommendations for optimal practices and potential system improvements are included in the research, addressing the growing need for efficient cooling solutions amidst escalating computational demands.more » « less
-
Indoor air quality (IAQ) is crucial for the health, well-being, and productivity of office occupants. IAQ is strongly influenced by occupancy and the operational mode of the heating, ventilation, and air conditioning (HVAC) system. This study investigates the spatiotemporal variations in ozone (O3) and carbon dioxide (CO2) concentrations throughout the HVAC system of a LEED-certified office building. A four-month field measurement campaign was conducted at the Ray W. Herrick Laboratories, employing an automated multi-point sampling system to monitor O3 and CO2 at eight locations throughout the HVAC system. The objectives of this study are to characterize the spatiotemporal distribution of these gases under different ventilation modes and occupancy levels, and to identify O3 loss mechanisms in the office and its HVAC system. Spatiotemporal variations in O3 and CO2 concentrations were observed throughout the HVAC system. Results indicate that outdoor air exchange rates (AERs) significantly impact indoor O3 levels, with higher AERs resulting in increased indoor O3 but reduced CO2 concentrations. Measurements reveal that HVAC filters and ducts contribute to O3 loss, with up to 18% O3 removal observed in the longest HVAC duct segment. Additionally, occupancy influences O3 deposition onto human skin and clothing surfaces. This research underscores the limitations of ventilation standards that focus only on CO2, highlighting the need for ventilation strategies that consider the effects of occupancy and outdoor AERs on different gases. By integrating multi-point gas sampling into building automation systems, more effective control strategies can be developed to enhance IAQ and occupant health while reducing energy consumption.more » « less
-
null (Ed.)We deploy a fully coupled thermo-fluidic finite element approach to simulating natural ventilation in a sustainably designed building with complex geometry. The 'interlock house' uses building design for climate control instead of mechanical means (such as air conditioning). Therefore, accurately modeling the natural ventilation flows is crucial to assess thermal comfort in such designs. A residual-based variational multiscale method (VMS) is employed, which is a Large Eddy Simulation (LES) type approach to turbulence modeling. Air diffusion performance index (ADPI) and predicted mean vote (PMV) are computed to investigate thermal comfort in both configurations. This work illustrates the ability of the framework to comprehensively model and predict natural ventilation under various operating scenarios.more » « less
An official website of the United States government