Less defective, nitrogen-doped 3-dimensional graphene (N3DG) and defect-rich, nitrogen-doped 3-dimensional graphene (N3DG-D) were made by the thermal CVD (Chemical Vapor Deposition) process via varying the carbon precursors and synthesis temperature. These modified 3D graphene materials were compared with pristine 3-dimensional graphene (P3DG), which has fewer defects and no nitrogen in its structure. The different types of graphene obtained were characterized for morphological, structural, and compositional assessment through Scanning Electron Microscopy (SEM), Raman Spectroscopy, and X-ray Photoelectron Spectroscopy (XPS) techniques. Electrodes were fabricated, and electrochemical characterizations were conducted to evaluate the suitability of the three types of graphene for heavy metal sensing (lead) and Electric Double-Layer Capacitor (EDLC) applications. Initially, the various electrodes were treated with a mixture of 2.5 mM Ruhex (Ru (NH3)6Cl3 and 25 mM KCl to confirm that all the electrodes underwent a reversible and diffusion-controlled electrochemical process. Defect-rich graphene (N3DG-D) revealed the highest current density, followed by pristine (P3DG) and less-defect graphene (N3DG). Further, the three types of graphene were subjected to a sensing test by square wave anodic stripping voltammetry (SWASV) for lead detection. The obtained preliminary results showed that the N3DG material provided a great lead-sensing capability, detecting as little as 1 µM of lead in a water solution. The suitability of the electrodes to be employed in an Electric Double-Layer Capacitor (EDLC) was also comparatively assessed. Electrochemical characterization using 1 M sodium sulfate electrolyte was conducted through cyclic voltammetry and galvanostatic charge-discharge studies. The voltammogram and the galvanostatic charge-discharge (GCD) curves of the three types of graphene confirmed their suitability to be used as EDLC. The N3DG electrode proved superior with a gravimetric capacitance of 6.1 mF/g, followed by P3DG and N3DG, exhibiting 1.74 mF/g and 0.32 mF/g, respectively, at a current density of 2 A/g.
more »
« less
Function Graded Carbon Micro‐Structures for Powerless Photon Sensing with Intriguing µm‐Scale Position Sensitivity
Abstract Partial laser treatment is introduced to carbon‐based microfibers to generate excellent photon sensing capability without bias. This treatment brings about a Seebeck coefficient distribution along the sample's length, out of which a photovoltage with no external bias is generated and sensed. Using a line‐shaped laser spot, carbon microfiber (CMF), graphene microfiber (GMF), and graphene aerogel fiber (GAF) are investigated for their response to µm‐scale photon irradiation. A higher sensitivity for the incident photon is found for the GAF with no position sensitivity. More Seebeck coefficient variation is also observed for the GAF considering the amount of laser power used for the laser treatment. A weaker Seebeck coefficient spatial variation is observed for the GMF compared with the GAF. However, its photovoltage shows an abrupt magnitude change from the laser‐treated region to the non‐treated one. Despite the low spatial variation of the Seebeck coefficient for the CMF, it features an excellent and accurate position‐sensitive photoresponse with polarization change over a distance of ≈100 µm. Such unique capability prompts novel applications in using partially annealed CMF for sensing the position of optical beams at the microscale.
more »
« less
- PAR ID:
- 10641046
- Publisher / Repository:
- Wiley Blackwell (John Wiley & Sons)
- Date Published:
- Journal Name:
- Advanced Optical Materials
- Volume:
- 12
- Issue:
- 2
- ISSN:
- 2195-1071
- Format(s):
- Medium: X
- Sponsoring Org:
- National Science Foundation
More Like this
-
-
Abstract Traditional deep fluorescence imaging has primarily focused on red‐shifting imaging wavelengths into the near‐infrared (NIR) windows or implementation of multi‐photon excitation approaches. Here, the advantages of NIR and multiphoton imaging are combined by developing a dual‐infrared two‐photon microscope that enables high‐resolution deep imaging in biological tissues. This study first computationally identifies that photon absorption, as opposed to scattering, is the primary contributor to signal attenuation. A NIR two‐photon microscope is constructed next with a 1640 nm femtosecond pulsed laser and a NIR PMT detector to image biological tissues labeled with fluorescent single‐walled carbon nanotubes (SWNTs). Spatial imaging resolutions are achieved close to the Abbe resolution limit and eliminate blur and background autofluorescence of biomolecules, 300 µm deep into brain slices and through the full 120 µm thickness of aNicotiana benthamianaleaf. NIR‐II two‐photon microscopy can also measure tissue heterogeneity by quantifying how much the fluorescence power law function varies across tissues, a feature this study exploits to distinguish Huntington's Disease afflicted mouse brain tissues from wildtype. These results suggest dual‐infrared two‐photon microscopy can accomplish in‐tissue structural imaging and biochemical sensing with a minimal background, and with high spatial resolution, in optically opaque or highly autofluorescent biological tissues.more » « less
-
In this research, a novel interdigitated gear-shaped, graphene-based electrochemical biosensor was developed for the detection of dopamine (DA). The sensor’s innovative design improves the active surface area by 94.52% and 57% compared to commercially available Metrohm DropSens 110 screen-printed sensors and printed circular sensors, respectively. The screen-printed electrode was fabricated using laser processing and modified with graphene polyaniline conductive ink (G-PANI) to enhance its electrochemical properties. Fourier Transform Infrared (FTIR) Spectroscopy and X-ray diffraction (XRD) were employed to characterize the physiochemical properties of the sensor. Dopamine, a neurotransmitter crucial for several body functions, was detected within a linear range of 0.1–100 µM, with a Limit of Detection (LOD) of 0.043 µM (coefficient of determination, R2 = 0.98) in phosphate-buffer saline (PBS) with ferri/ferrocyanide as the redox probe. The performance of the sensor was evaluated using cyclic voltammetry (CV) and Chronoamperometry, demonstrating high sensitivity and selectivity. The interdigitated gear-shaped design exhibited excellent repeatability, with a relative standard deviation (RSD) of 1.2% (n = 4) and reproducibility, with an RSD of 2.3% (n = 4). In addition to detecting dopamine in human serum, the sensor effectively distinguished dopamine in a ternary mixture containing uric acid (UA) and ascorbic acid (AA). Overall, this novel sensor design offers a reliable, disposable, and cost-effective solution for dopamine detection, with potential applications in medical diagnostics and neurological research.more » « less
-
Abstract The accurate, continuous analysis of healthcare-relevant gases such as nitrogen oxides (NO x ) in a humid environment remains elusive for low-cost, stretchable gas sensing devices. This study presents the design and demonstration of a moisture-resistant, stretchable NO x gas sensor based on laser-induced graphene (LIG). Sandwiched between a soft elastomeric substrate and a moisture-resistant semipermeable encapsulant, the LIG sensing and electrode layer is first optimized by tuning laser processing parameters such as power, image density, and defocus distance. The gas sensor, using a needlelike LIG prepared with optimal laser processing parameters, exhibits a large response of 4.18‰ ppm −1 to NO and 6.66‰ ppm −1 to NO 2 , an ultralow detection limit of 8.3 ppb to NO and 4.0 ppb to NO 2 , fast response/recovery, and excellent selectivity. The design of a stretchable serpentine structure in the LIG electrode and strain isolation from the stiff island allows the gas sensor to be stretched by 30%. Combined with a moisture-resistant property against a relative humidity of 90%, the reported gas sensor has further been demonstrated to monitor the personal local environment during different times of the day and analyze human breath samples to classify patients with respiratory diseases from healthy volunteers. Moisture-resistant, stretchable NO x gas sensors can expand the capability of wearable devices to detect biomarkers from humans and exposed environments for early disease diagnostics.more » « less
-
For this experimental study on evaporation of water from graphene, two graphene samples with different thickness and microstructure were used. Figure 1 shows the representative optical and scanning electron microscope (SEM) images of the two samples. Sample 1, shown in Figure 1a-b, is a 3 to 4 atomic layer of continuous graphene sheet grown on copper substrate via chemical vapor deposition (CVD) and was subsequently transferred to a quartz substrate using a wet chemical method reported previously [5]. The graphene thickness is at 1.2 nm to 1.4 nm, as measured by Atomic Force Microscopy. Sample 2, shown in Figure 1c-d, represents an inkjet-printed reduced graphene oxide on silicon and subsequently treated with a direct pulsed laser writing (DPLW) process for surface 3D-nanostructuring. The layer thickness is between 6 µm and 7 µm.more » « less
An official website of the United States government
