skip to main content
US FlagAn official website of the United States government
dot gov icon
Official websites use .gov
A .gov website belongs to an official government organization in the United States.
https lock icon
Secure .gov websites use HTTPS
A lock ( lock ) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.


This content will become publicly available on November 1, 2026

Title: Design Criteria of Non-Isolated Bidirectional DC-DC Converters: A Review
Battery energy storage systems are widely used for renewable power generation and electric transportation systems. Bidirectional DC-DC converters (BDCs) are key components in such systems, enabling bidirectional power flow in battery charging and discharging modes. BDCs can be categorized into isolated and non-isolated. Non-isolated BDCs have lower volume, weight, and power losses, suitable for compact structures without needing galvanic isolation. In this paper, a comprehensive literature review is conducted for non-isolated BDCs, covering soft switching, current ripple reduction, high voltage gain and resiliency techniques. Soft switching aims to reduce switching losses and improve efficiency, including auxiliary circuits and non-auxiliary methods, such as interleaved structures, phase-shift modulation, and synchronous rectification. Current ripple reduction focuses on capacitive loop configurations, interleaved structures, and coupled inductor-based methods. Batteries are low-voltage power sources, BDCs can increase the output voltage to a level required by the applications through an appropriate voltage gain, and high voltage gain techniques include capacitor-based, magnetic-based, and combined networks, and mixed structures. Resiliency is explored to ensure reliable operations under adverse conditions. This review provides valuable insights into developing more efficient, reliable, and high-performance BDCs, addressing the evolving demands of modern energy systems. Future research directions in non-isolated BDCs are recommended in this paper.  more » « less
Award ID(s):
2330582
PAR ID:
10641476
Author(s) / Creator(s):
 ;  
Publisher / Repository:
IEEE Xplore
Date Published:
Journal Name:
IEEE Transactions on Industry Applications
Volume:
61
Issue:
6
ISSN:
0093-9994
Page Range / eLocation ID:
8771 to 8798
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. null (Ed.)
    A high-voltage-gain dc-dc converter topology is proposed for renewable energy applications. The proposed coupled-inductor-based high-gain dc-dc converter features reduced input current ripple. The semiconductor elements voltage spikes due to the leakage inductance are prevented through the use of a clamping circuit. The Clamping circuit helps recover the leakage inductance stored energy, which causes voltage spikes on the switch. This results in the selection of elements with lower voltage ratings. Power switches with lower voltage ratings lead to lower conduction losses and improved system efficiency. The DC component of the inductor magnetizing current is zero. Consequently, no energy is stored in the inductor core, and the losses are further reduced. 
    more » « less
  2. Unfolding-based single-stage ac-dc converters offer benefits in terms of efficiency and power density due to the low-frequency operation of the Unfolder, resulting in negligible switching losses. However, the operation of the Unfolder results in time-varying dc voltages at the input of the subsequent dc-dc converter, complicating its soft-switching analysis. The complication is further enhanced due to the nonlinear nature of the output capacitance ( Coss ) of MOSFETs employed in the dc-dc converter. Furthermore, unlike two-stage topologies with a constant dc-link voltage, as seen in high-frequency grid-tied converters, grid voltage fluctuations also impact the dc input voltages of the dc-dc converter in unfolding-based systems. This work comprehensively analyzes the soft-switching phenomenon in the T-type primary bridge-based dc-dc converter used in unfolding-based topologies, considering all the aforementioned challenges. An energy-based methodology is proposed to determine the minimum zero-voltage switching (ZVS) current and ZVS time during various switching transitions of the T-type bridge. It is shown that the existing literature on the ZVS analysis of the T-type bridge-based resonant dc-dc converter, relying solely on capacitive energy considerations, substantially underestimates the required ZVS current values, with errors reaching up to 50%. The proposed analysis is verified through both simulation and hardware testing. The hardware testing is conducted on a 20-kW 3- ϕ unfolding-based ac-dc converter designed for high-power electric vehicle battery charging applications. The ZVS analysis is verified at various grid angles with the proposed analysis ensuring a complete ZVS operation of the ac-dc system throughout the grid cycle. 
    more » « less
  3. null (Ed.)
    A new high-voltage-gain non-isolated dc-dc topology for applications in renewable energies is proposed. A coupled inductor with three windings is used to increase the proposed topology voltage gain. In addition to increasing the voltage gain, the proposed topology also has other prominent features including continuous input current and zero dc magnetizing inductance current, which reduces the losses and size of coupled inductor core. Furthermore, the continuous input current guarantees a low-volume input filter, which is essential for renewable energy applications. The leakage inductor stored energy is recycled via the diode and capacitor and transferred to the converter output for increasing the efficiency and reducing voltage stresses on the converter components. 
    more » « less
  4. Second-order ripples occur in the voltage and current during any DC–AC power conversion. These conversions occur in the voltage source inverters (VSIs), current source inverters (CSIs), and various single-stage inverters (SSIs) topologies. The second-order ripples lead to oscillating source node currents and DC bus voltages when there is an interconnection between the AC and DC microgrids or when an AC load is connected to the DC bus of the microgrid. Second-order ripples have various detrimental effects on the sources and the battery storage. In the storage battery, they lead to the depletion of electrodes. They also lead to stress in the converter or inverter components. This may lead to the failure of a component and hence affect the reliability of the system. Furthermore, the second-order ripple currents (SRCs) lead to ripple torque in wind turbines and lead to mechanical stress. SRCs cause a rise in the temperature of photovoltaic panels. An increase in the temperature of PV panels leads to a reduction in the power generated. Furthermore, the second-order voltage and current oscillations lead to a varying maximum power point in PV panels. Hence, the maximum power may not be extracted from it. To mitigate SRCs, oversizing of the components is needed. To improve the lifespan of the sources, storage, and converter components, the SRCs must be mitigated or kept within the desired limits. In the literature, different methodologies have been proposed to mitigate and regulate these second-order ripple components. This manuscript presents a comprehensive review of different effects of second-order ripples on different sources and the methodologies adopted to mitigate the ripples. Different active power decoupling methodologies, virtual impedance-based methodologies, pulse width modulation-based signal injection methodologies, and control methods adopted in distributed power generation methods for DC microgrids have been presented. The application of ripple control methods spans from single converters such as SSIs and VSIs to a network of interconnected converters. Furthermore, different challenges in the field of virtual impedance control and ripple mitigation in distributed power generation environments are discussed. This paper brings a review regarding control methodologies to mitigate and regulate second-order ripples in DC–AC conversions and microgrids. 
    more » « less
  5. null (Ed.)
    This paper presents a voltage multiplier topology that is suitable for a low-ripple high-voltage dc generation. The topology has a number of voltage multipliers connected in series and driven at different phases. Compared to a single-phase multiplier, an n-phase voltage multiplier has an output ripple that is smaller by n times. Since the ripple frequency is simultaneously increased by n times, a simple RC lowpass filter further reduces the ripple amplitude by n times, resulting in ripple reduction of n^2 times. We demonstrate the ripple reduction of the proposed topology using a 6 V-to-800 V power supply with a 16-stage four-phase bipolar voltage multiplier. The output ripple frequency is eight times the converter's switching frequency and the ripple amplitude is significantly smaller than the conventional single-phase voltage multiplier. 
    more » « less