This study develops and experimentally validates an innovative technique for enhancing the seismic performance of steel beam to column moment connections. The technique involves reducing the strength of specified regions of the beam flanges by exposing them to high temperatures followed by slow cooling. Analogous to the reduced beam section (RBS) connection, yielding and plastic hinge formation is promoted in the heat-treated beam section (HBS). Moreover, because the elastic and inelastic modulus of the steel is unmodified by the heat-treatment and the beam cross section is not altered, an HBS connection does not sacrifice elastic stiffness or buckling resistance as does the RBS. Design of the HBS connection was performed through detailed finite element analysis and material testing. Two large scale connections modified with the HBS technique were tested in this study. The test program showed that the proposed heat-treatment technique was successful in the promotion of yielding and plastic hinge development in the heat-treated regions with specimens attaining interstory drifts as high as 6% without weld or near weld fracture. Strength degradation due to beam buckling within the HBS was the observed failure mechanism in both specimens. Detail analyses of strain and beam deformation data are presented to explain the HBS connection plastic hinge formation and gradual strength degradation. Broader applications of the technique to other structural components are identified.  more » « less
Award ID(s):
0936547
NSF-PAR ID:
10026084
Author(s) / Creator(s):
; ;
Date Published:
Journal Name:
Journal of constructional steel research
Volume:
109
ISSN:
1873-5983
Page Range / eLocation ID:
34-46
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. This study develops two (2) simple but effective techniques for enhancing buckling resistance of welded steel moment connections (WSMCs). The ANSI/AISC 358-10 prequalified connections satisfy the 4% interstory drift requirement, however experimental studies have shown that their strength degradation may initiate as early as 3% drift. This strength degradation has been observed to be initiated by buckling of the beam web which is followed by buckling of the beamflange and twisting of the beam. Consequently, buildings with the prequalified connections may sustain significant buckling damages under severe earthquakes and it is questionable as to whether these connections are capable of resisting gravity loads or lateral loads from strong aftershocks following a severe earthquake. To improve upon these shortcomings, two (2) performance enhancing techniques are proposed and investigated through finite element analysis (FEA). The more promising of the two involves reinforcing the beam web in the expected plastic hinge with a web reinforcement plate. Finite element analysis demonstrated that this reinforcement enhances the beam buckling resistance of WSMCs and thereby significantly reduces the beam buckling damages even at 5% interstory drift. The potential of this technique is analytically and experimentally demonstrated for the recently developed heat-treated beam section (HBS) WSMC. Test results confirm that the web reinforcement plate was effective in reducing local buckling damage and associated strength degradation, thereby improving the performance of HBS WSMCs. Areas for application and future development of the proposed techniques are identified. 
    more » « less
  2. Introductory steel design courses focus on the analysis and design of primary members, which typically include tension members and connections, compression members, flexural members, and beam-columns. Introducing structural steel design concepts to students presents its fair share of challenges. First, it is difficult for students to visualize and accurately predict the potential failure modes of a tension member: yielding of the gross section, rupture of the net section, and block shear. Second, it is also difficult for students to visualize the buckling modes of steel columns, which vary with shape and type of bracing. Students particularly struggle with the determination of buckling modes between strong and weak axes based on effective lengths. Third, flexural failure modes of steel beams are very difficult for students to visualize and understand when each mode controls. The failure modes are complex and fall into three categories for compact shapes: yielding of the cross section, inelastic lateral torsional buckling, and elastic lateral torsional buckling, which is dependent on the unbraced length of the compression flange. Non-compact sections also include local buckling of the flange or web, but identifying the relationship between the unbraced length and beam span and how the unbraced length affects the flexural capacity tends to be the most difficult concept for students to grasp. This paper provides a detailed overview of the design, fabrication, and implementation of three large-scale experiential learning modules for an undergraduate steel design course. The first module focuses on the tension connections by providing physical models of various failure types including yielding of the gross section, rupture of the net section, and block shear; the second module focuses on the capacity of columns with different amounts of lateral bracing about the weak axis; and the third module focuses on the flexural strength of a beam with different unbraced lengths to illustrate the difference between lateral torsional buckling and flange local buckling/yielding of the gross section. The three modules were used throughout the steel design course at Saint Louis University and Rose-Hulman Institute of Technology to illustrate the failure mechanisms associated with the design of steel structures. 
    more » « less
  3. A vast amount of experimental and analytical research has been conducted related to the seismic behavior and performance of concrete filled steel tubular (CFT) columns. This research has resulted in a wealth of information on the component behavior. However, analytical and experimental data for structural systems with CFT columns is limited, and the well known behavior of steel or concrete structures is assumed valid for designing these systems. This paper presents the development of an analytical model for nonlinear analysis of composite moment resisting frame (CFT MRF) systems with CFT columns and steel wide flange (WF) beams under seismic loading. The model integrates component models for steel WF beams, CFT columns, connections between CFT columns and WF beams, and CFT panel zones. These component models account for nonlinear behavior due to steel yielding and local buckling in the beams and columns, concrete cracking and crushing in the columns, and yielding of panel zones and connections. Component tests were used to validate the component models. The model for a CFT MRF considers second order geometric effects from the gravity load bearing system using a lean on column. The experimental results from the testing of a four story CFT MRF test structure are used as a benchmark to validate the modeling procedure. An analytical model of the test structure was created using the modeling procedure and imposed displacement analyses were used to reproduce the tests with the analytical model of the test structure. Good agreement was found at the global and local level. The model reproduced reasonably well the story shear story drift response as well as the column, beam and connection moment rotation response, but overpredicted the inelastic deformation of the panel zone. 
    more » « less
  4. Thin (slender) steel plates possess shear strength beyond the elastic buckling load which is commonly referred to as the post-buckling capacity. Semi-empirical equations based on experimental tests of plate girders have been used for decades to predict the ultimate post-buckling strength of slender webs. However, several recent studies have shown that the current models for predicting the ultimate shear post-buckling capacity of thin plates are based on some incorrect assumptions regarding their mechanical behavior. As a result, the current design equations provide an approximate estimate of capacity for the range of parameters in the test data upon which they are founded. This paper explores the fundamental behavior of thin plates under pure shear. Such a fundamental examination of shear post-buckling behavior in thin plates is needed to enable design procedures that can optimize a plate’s shear strength and load-deformation performance for a wider range of loading and design parameters. Using finite element analyses, which are validated against available results of previous experimental tests, outputs such as plastic strains, von Mises stresses, principal stresses, and principal stress directions are examined on a buckled plate acting in pure shear. The internal bending, shear, and membrane stresses in the plate’s finite elements are also evaluated. In this study, these evaluations are performed for a simply-supported plate with an aspect ratio equal to 1.0 and slenderness ratio equal to 134. Results show that localized bending in the plates due to the out-of-plane post-buckling deformations appear to be a significant factor in the ultimate shear post-buckling capacity of the plate. Also, the compressive stresses continue to increase beyond the onset of elastic buckling in some regions of the plate, contrary to current design assumptions. Overall, this study provides new insights into the mechanics of shear post-buckling behavior of thin plates that can be exploited for design procedures that are consistent with mechanical behavior. 
    more » « less
  5. This research investigated experimentally the seismic performance of steel gravity framing with a concrete slab at the system level. Two half-story, two-by-three bay steel gravity frame specimens were tested under cyclic loading. Bolted-bolted double-angle connections were used for a beam-to-column gravity connection. Primary design variables and construction details include the orientation of the metal deck to the loading direction, the presence or absence of metal deck seams on secondary beams, and the contribution of additional reinforcement bars in the concrete slab. Concrete blocks were positioned at the midpoint of each bay to simulate gravity loads, and a quasi-static displacement-controlled cyclic loading protocol was applied to the specimen using three hydraulic actuators. These investigations confirmed general observations from previous subassembly testing programs that the composite steel gravity framing system can provide substantial flexural stiffness, strength, and ductility under cyclic loading. Further, the test findings showed that the primary design variables and construction details significantly affected the cyclic behavior of composite gravity connections. Comparing the test results from a multi-bay setup and a subassembly testing setup, the cyclic behavior showed remarkable differences, especially for cases with weak axis decking or strong axis decking with a seam. These large differences are attributed to a significant separation of the girder from the column in the subassembly testing setup, which may not be present in a real building. Virtually all previous cyclic loading tests on gravity connections have been conducted in subassembly test setups. These subassembly tests are therefore the basis for the models that are currently used to include gravity frame connections in the seismic performance assessment of buildings, and these models may be quite inaccurate in some cases. The data generated in this system-level testing program is intended to support efforts to develop improved models of gravity connections subject to seismic loading. 
    more » « less