- Award ID(s):
- 1626326
- Publication Date:
- NSF-PAR ID:
- 10108549
- Journal Name:
- MRS Communications
- Page Range or eLocation-ID:
- 1 to 8
- ISSN:
- 2159-6859
- Sponsoring Org:
- National Science Foundation
More Like this
-
Parvinzadeh Gashti, Mazeyar (Ed.)The simple, accurate, and rapid detection of foodborne pathogens is essential for public health. Development of an immunomagnetic separation (IMS) multiplex touchdown PCR (IMS–multiplex TD–PCR) assay for simultaneous detection and distinguishing of C. jejuni and C. coli is reported herein. Polyclonal antibody (pAb) against multiepitope antigen (MEA) was conjugated to ferromagnetic nanoparticles (FMNs) to produce anti-MEA FMNs. Optimal anti-MEA FMNs loading yielded 26.7 μg of immunoglobulin G (IgG) molecules per mg of FMNs with an average size of 72 ± 9 nm, corresponding to an 83% rate of pAb conjugation. Anti-MEA FMNs (20 μg) for IMS captured culturable C. jejuni cells at 3.54 × 10 2 colony-forming unit (CFU)/mL in pure culture, while higher amounts (40 and 60 μg) reduced the recovery. The scanning electron microscope (SEM) analysis revealed the attachment of anti-MEA FMNs to target bacteria, forming aggregated cells and magnetic nanoparticles in ellipse-like shapes. The subsequent multiplex TD–PCR assay simultaneously detected and distinguished C. jejuni and C. coli at 104 CFU/mL in mixed culture and at 103 CFU/mL for each individual species. Furthermore, the limit of detection (LOD) of the IMS–multiplex TD–PCR assay was 104 CFU/g in spiked chicken breast samples. Specificity was 100% for both C. jejuni and C. coli as none ofmore »
-
Surface-enhanced Raman spectroscopy (SERS) has great potential as an analytical technique for environmental analyses. In this study, we fabricated highly porous gold (Au) supraparticles ( i.e. , ∼100 μm diameter agglomerates of primary nano-sized particles) and evaluated their applicability as SERS substrates for the sensitive detection of environmental contaminants. Facile supraparticle fabrication was achieved by evaporating a droplet containing an Au and polystyrene (PS) nanoparticle mixture on a superamphiphobic nanofilament substrate. Porous Au supraparticles were obtained through the removal of the PS phase by calcination at 500 °C. The porosity of the Au supraparticles was readily adjusted by varying the volumetric ratios of Au and PS nanoparticles. Six environmental contaminants (malachite green isothiocyanate, rhodamine B, benzenethiol, atrazine, adenine, and gene segment) were successfully adsorbed to the porous Au supraparticles, and their distinct SERS spectra were obtained. The observed linear dependence of the characteristic Raman peak intensity for each environmental contaminant on its aqueous concentration reveals the quantitative SERS detection capability by porous Au supraparticles. The limit of detection (LOD) for the six environmental contaminants ranged from ∼10 nM to ∼10 μM, which depends on analyte affinity to the porous Au supraparticles and analyte intrinsic Raman cross-sections. The porous Au supraparticlesmore »
-
Abstract Hydroxyl radicals (•OH) are well known as crucial chemicals for maintaining the normal activities of human cells; however, the excessive concentration of •OH disrupts their normal function, causing various diseases, including liver and heart diseases, cancers, and neurological disorders. The detection of •OH as a biomarker is thus essential for the early diagnosis of these serious conditions. Herein, a novel electrochemical sensor comprising a composite of cerium oxide nanoclusters, gold nanoparticles, and a highly conductive carbon was developed for detecting •OH. Cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) were employed to characterize the signals generated by the interaction of the composite with •OH radicals. The CV results revealed that the developed sensor could accurately and selectively detect •OH in the Fenton reaction. The sensor demonstrated a linear relationship between the current peak and •OH concentration in the range 0.05 - 0.5 mM and 0.5 - 5 mM with a limit of detection (LOD) of 58 µM. In addition, EIS studies indicated that this electrochemical sensor could distinguish between •OH and similar reactive oxygen species (ROS), like hydrogen peroxide (H2O2). It is also worth mentioning that additional merits, such as reproducibility, repeatability, and stability of the sensor were confirmed.
-
The electrophoretic deposition (EPD) of citrate-stabilized Au nanoparticles (cit-Au NPs) occurs on indium tin oxide (ITO)-coated glass electrodes upon electrochemical oxidation of hydroquinone (HQ) due to the release of hydronium ions. Anodic stripping voltammetry (ASV) for Au oxidation allows the determination of the amount of Au NP deposition under a specific EPD potential and time. The binding of Cr 3+ to the cit-Au NPs inhibits the EPD by inducing aggregation and/or reducing the negative charge, which could lower the effective NP concentration of the cit-Au NPs and/or lower the electrophoretic mobility. This lowers the Au oxidation charge in the ASV, which acts as an indirect signal for Cr 3+ . The binding of melamine to cit-Au NPs similarly leads to aggregation and/or lowers the negative charge, also resulting in reduction of the ASV Au oxidation peak. The decrease in Au oxidation charge measured by ASV increases linearly with increasing Cr 3+ and melamine concentration. The limit of detection (LOD) for Cr 3+ is 21.1 ppb and 16.0 ppb for 15.1 and 4.1 nm diameter cit-Au NPs, respectively. Improving the sensing conditions allows for as low as 1 ppb detection of Cr 3+ . The LOD for melamine is 45.7 ppbmore »
-
Abstract The GuLF Long-term Follow-up Study (GuLF STUDY) is investigating potential adverse health effects of workers involved in the Deepwater Horizon (DWH) oil spill response and cleanup (OSRC). Over 93% of the 160 000 personal air measurements taken on OSRC workers were below the limit of detection (LOD), as reported by the analytic labs. At this high level of censoring, our ability to develop exposure estimates was limited. The primary objective here was to reduce the number of measurements below the labs’ reported LODs to reflect the analytic methods’ true LODs, thereby facilitating the use of a relatively unbiased and precise Bayesian method to develop exposure estimates for study exposure groups (EGs). The estimates informed a job-exposure matrix to characterize exposure of study participants. A second objective was to develop descriptive statistics for relevant EGs that did not meet the Bayesian criteria of sample size ≥5 and censoring ≤80% to achieve the aforementioned level of bias and precision. One of the analytic labs recalculated the measurements using the analytic method’s LOD; the second lab provided raw analytical data, allowing us to recalculate the data values that fell between the originally reported LOD and the analytical method’s LOD. We developed rulesmore »