A positive cloud‐to‐ground (+CG) lightning flash containing a single stroke with a peak current of approximately +310 kA followed by a long continuing current triggered seven upward lightning flashes from tall structures. The flashes were observed on 4 June 2016 at the Tall Object Lightning Observatory in Guangzhou, Guangdong Province, China. The optical and electric field characteristics of these flashes were analyzed using synchronized two‐station data from two high‐speed video cameras, one total‐sky lightning channel imager, two lightning channel imagers, and two sets of slow and fast electric field measuring systems. Three upward flashes were initiated sequentially in the field of view of high‐speed video cameras. One of them was initiated approximately 0.35 ms after the return stroke of +CG flash from the Canton Tower, the tallest structure within a 12‐km radius of the +CG flash, while the other two upward flashes were initiated from two other, more distant tall objects, approximately 18 ms after the +CG flash stroke. The initiation of the latter two upward flashes could be caused by the combined effect of the return stroke of +CG flash, its associated continuing current, and K process in the cloud. Each of these three upward flashes contained multiple downward leader/upward return stroke sequences, with the first leader/return stroke sequence of the second and third flashes occurring only after the completion of the last leader/return stroke sequence of the preceding flash. The total number of strokes in the three upward flashes was 13, and they occurred over approximately 1.5 s.
- Award ID(s):
- 1427734
- NSF-PAR ID:
- 10218014
- Date Published:
- Journal Name:
- Meteorology and Atmospheric Physics
- Volume:
- 132
- Issue:
- 4
- ISSN:
- 0177-7971
- Page Range / eLocation ID:
- 489 to 514
- Format(s):
- Medium: X
- Sponsoring Org:
- National Science Foundation
More Like this
-
Abstract -
Abstract This study reports on spectroscopy results from a high‐speed optical spectrograph of two naturally occurring lightning return strokes. The two strokes occurred near Melbourne, FL and were from two separate flashes that were about 10 min apart and had National Lightning Detection Network (NLDN) peak currents of −19 and −63 kA. The larger peak current stroke was from a dart leader and was the last stroke in a 5 return stroke flash, while the −19 kA stroke originated from a stepped leader and was the only stroke in that flash. From the flash spectra, the return stroke channel temperature was calculated using the neutral lines of 715.7 nm (OI) and 777.4 nm (OI). In addition to the use of the neutral emission lines, the use of novel instrumentation and image processing techniques allowed the temperature to be calculated for nearly the entire visible channel (several km) and for long durations (several hundred μs). This enables temperature estimates on an unprecedented spatial and temporal scale, which show that the vertical temperature profile is not uniform across the channel. The lower altitudes are significantly hotter than higher altitudes near the time of the return stroke, with temperature gradients along the channel as large as 12,000 K/km. The rate of cooling of the channel is also initially 3–4 times larger at lower altitudes in comparison with the segments at higher altitudes. The stroke with the larger peak current shows larger maximum temperatures, larger temperature gradients along the channel, and also cools quicker.
-
Insights on Space‐Leader Characteristics and Evolution in Natural Negative Cloud‐to‐Ground Lightning
Abstract We present sub‐microsecond‐scale, high‐speed video camera observations of three negative stepped leaders in cloud‐to‐ground flashes with return‐stroke peak currents (estimated by the U.S. National Lightning Detection Network) of −17, −104, and −228 kA. The camera frame exposure times for these observations were 1.8, 1.0, and 0.74 µs, respectively. The 0.74 µs exposure time is the shortest reported to date. We observed the temporal and spatial evolution of space leaders from their inception to their attachment to the pre‐existing leader channel (PELC). For stepped leaders that led to return strokes having higher peak currents, the space leaders appear to have incepted at farther median two‐dimensional distances from their respective PELC‐attachment points. These median distances were 6.1, 16.6, and 17.6 m, respectively, for the three strokes. Our observations indicate that space leader characteristics are likely influenced by stepped‐leader line‐charge‐density, which is expected to be higher in strokes with higher return‐stroke peak currents.
-
Abstract The dissonant development of positive and negative lightning leaders is a central question in atmospheric electricity. It is also the likely root cause of other reported asymmetries between positive and negative lightning flashes, including the ones regarding: stroke multiplicity, recoil activity, leader velocities, and emission of energetic radiation. In an effort to contrast lightning leaders of different polarities, we highlight the staggering differences between two rocket‐triggered lightning flashes. The flash beginning with upward positive leaders exhibits an initial continuous current stage followed by multiple sequences of dart leaders and return strokes. On the other, in its opposite‐polarity counterpart, the upward development of negative leaders is by itself the entire flash. As a result, the flash with negative leaders is faster, briefer, transfers less charge to the ground, has lower currents, and smaller spatial extent. We conclude by presenting a discussion on the three fundamental leader propagation modes.
-
Abstract Previous studies have shown that subsequent leaders in positive cloud‐to‐ground lightning (+CG) flashes rarely traverse pre‐existing channels to ground. In this paper, we present evidence that this actually can be common, at least for some thunderstorms. Observations of +CG flashes in a supercell storm in Argentina by Córdoba Argentina Marx Meter Array (CAMMA) are presented, in which 54 (64%) of 84 multiple‐stroke +CG flashes had subsequent leaders following a pre‐existing channel to ground. These subsequent positive leaders are found to behave similarly to their negative counterparts, including propagation speeds along pre‐existing channels with a median of 8 × 106 m/s, which is comparable to that of negative dart leaders. Two representative multiple‐stroke +CG flashes are presented and discussed in detail. The observations reported herein call for an update to the traditional explanation of the disparity between positive and negative lightning.