skip to main content
US FlagAn official website of the United States government
dot gov icon
Official websites use .gov
A .gov website belongs to an official government organization in the United States.
https lock icon
Secure .gov websites use HTTPS
A lock ( lock ) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.


Title: Medindo os parâmetros de Stokes: Uma nova prática para ensino de óptica
Abstract Here, we implement a physics teaching laboratory practice that aims to investigate the Stokes parameters through the analysis of polarized light transmitted by polarizing optical elements. The practice was implemented according to the project-based learning methodology. All the investigated states of polarized light were generated using a homemade polarization simulator, comprising a light source (laser emitting at 670 nm) combined with different polarizing optical elements. We have shown that the practice is effective for obtaining the Stokes' parameters. Moreover, it can be easily designed as an advanced experimental project for optics teaching laboratories, with the purpose of confirming and advancing theoretical studies of the topic.  more » « less
Award ID(s):
1848418
PAR ID:
10249160
Author(s) / Creator(s):
; ; ; ;
Date Published:
Journal Name:
Revista Brasileira de Ensino de Física
Volume:
42
ISSN:
1806-1117
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. Abstract Optical chirality is an effective means in screening molecules and their enantiomers in bioengineering, and recently has garnered attention as an implementation of qubits in quantum information processing. The conventional detection of circularly polarized light (CPL) is based on phase retardation and polarization separation using multiple optical components. An intrinsic solid‐state chirality detection device would be favorable for easier integration and implementation. Optical spin injection to the spin‐momentum‐locked topological surface states of topological insulators (TIs) by circularly polarized light leads to a directional DC photocurrent and hence possible circular polarization detection. However, this DC photocurrent is also accompanied by other photo‐responses. Here, a photodetection strategy using a TI transistor which senses CPL without the use of any additional components is demonstrated, it achieves a uniform response over the entire device with a sensitivity ≈5.6%. The Stokes parameters can also be extracted by arithmetic operation of photocurrents obtained with different bias and gate for a complete characterization of a polarized light beam. Therefore, this method enables chirality detection and Stokes parameter analysis using a single device. The proposed miniaturized intrinsic chirality detectors facilitate polarimetry sensing in applications from circular dichroism spectroscopy to biomedical diagnosis. 
    more » « less
  2. Polarimetry is generally used to determine the polarization state of light beams in various research fields, such as biomedicine, astronomy, and materials science. In particular, the rotating quarter-wave plate polarimeter is an inexpensive and versatile option used in several single-wavelength applications to determine the four Stokes parameters. Extending this technique to broadband spectroscopic measurements is of great scientific interest since the information on light polarization is highly sensitive to anisotropic phenomena. However, the need for achromatic polarizing elements, especially quarter-wave plates, requires special attention in their modeling. In this study, we implemented a rotating retarder spectropolarimeter for broadband measurements using a commercially available quasi-achromatic biplate retarder over the visible range. Here, we present a comprehensive approach for troubleshooting this type of spectropolarimeter through the observation of artifacts stemming from the standard single-plate retarder model. Then, we derive a more suitable model for a quasi-achromatic retarder consisting of a biplate junction. This new biplate model requires knowledge of the intrinsic dispersive properties of the biplate, namely the equivalent retardance, fast axis tilt, and rotatory angle. Hence, in this study, we also show a self-consistent methodology to determine these biplate properties using the same polarimeter apparatus so that accurate Stokes parameters can be determined independently. Finally, the comparison of data generated with the standard single-plate and new biplate models shows a significant improvement in the measurement precision of the investigated polarization states, which confirms that remodeling the retarder for reliable spectropolarimetry is necessary. 
    more » « less
  3. Linear birefringence is a fundamental property of optically anisotropic media, defined by the difference in refractive index experienced by light polarized along orthogonal directions. It is usually manifested in microscopically aligned molecular systems, where a preferential direction of light–matter interaction is created. For instance, the anisotropic structure of calcite crystal causes the famous double-refraction phenomenon. Another common example is commercial adhesive tapes, which are polymeric materials possessing birefringent properties due to their manufacturing processes. The intrinsic relation between birefringence and molecular alignment forges a new analytical route to study materials such as polymeric thin films. Therefore, the capacity of measuring linear birefringence and its fast axis is of paramount importance for the science of anisotropic molecular systems. In this contribution, a comprehensive approach to acquire linear birefringence using rotating-sample transmission Stokes spectropolarimetry is presented and applied to transparent adhesive tapes as a case study. The experimental setup comprises a thermal light source and a spectropolarimeter capable of determining wavelength distributions of Stokes parameters. The samples are carefully aligned in a rotating mount and subjected to a fixed broadband vertically polarized light beam. Then, the transmitted light is analyzed using a rotating retarder type of spectropolarimeter. Through systematic variation of the sample’s angular position, the Stokes parameters of transmitted light are measured for each transmitted wavelength as a function of the sample’s angular position. The linear retardance and fast axis direction relative to the tape’s long axis are then determined from the modulation of Stokes parameters over sample rotation. The model derivation, experimental procedure, and signal processing protocol are described in detail, and the approach is verified with a simple correlation between linear retardance and the number of stacked layers of tape. 
    more » « less
  4. We demonstrate calibration and operation of a single wavelength (660 nm) Mueller matrix ellipsometer in normal transmission configuration using dual continuously rotating anisotropic mirrors. The mirrors contain highly spatially coherent nanostructure slanted columnar titanium thin films deposited onto optically thick gold layers on glass substrates. Upon rotation around the mirror normal axis, sufficient modulation of the Stokes parameters of light reflected at oblique angle of incidence is achieved. Thereby, the mirrors can be used as a polarization state generator and polarization state analyzer in a generalized ellipsometry instrument. A Fourier expansion approach is found sufficient to render and calibrate the effects of the mirror rotations onto the polarized light train within the ellipsometer. The Mueller matrix elements of a set of anisotropic samples consisting of a linear polarizer and a linear retarder are measured and compared with model data, and very good agreement is observed. 
    more » « less
  5. Efficient photosynthetic energy conversion requires quantitative, light-driven formation of high-energy, charge-separated states. However, energies of high-lying excited states are rarely extracted, in part because the congested density of states in the excited-state manifold leads to rapid deactivation. Conventional photosystem designs promote electron transfer (ET) by polarizing excited donor electron density toward the acceptor (“one-way” ET), a form of positive design. Curiously, negative design strategies that explicitly avoid unwanted side reactions have been underexplored. We report here that electronic polarization of a molecular chromophore can be used as both a positive and negative design element in a light-driven reaction. Intriguingly, prudent engineering of polarized excited states can steer a “U-turn” ET—where the excited electron density of the donor is initially pushed away from the acceptor—to outcompete a conventional one-way ET scheme. We directly compare one-way vs. U-turn ET strategies via a linked donor–acceptor (DA) assembly in which selective optical excitation produces donor excited states polarized either toward or away from the acceptor. Ultrafast spectroscopy of DA pinpoints the importance of realizing donor singlet and triplet excited states that have opposite electronic polarizations to shut down intersystem crossing. These results demonstrate that oppositely polarized electronically excited states can be employed to steer photoexcited states toward useful, high-energy products by routing these excited states away from states that are photosynthetic dead ends. 
    more » « less