We report a label-free acoustic microfluidic method to confine single, cilia-driven swimming cells in space without limiting their rotational degrees of freedom. Our platform integrates a surface acoustic wave (SAW) actuator and bulk acoustic wave (BAW) trapping array to enable multiplexed analysis with high spatial resolution and trapping forces that are strong enough to hold individual microswimmers. The hybrid BAW/SAW acoustic tweezers employ high-efficiency mode conversion to achieve submicron image resolution while compensating for parasitic system losses to immersion oil in contact with the microfluidic chip. We use the platform to quantify cilia and cell body motion for wildtype biciliate cells, investigating effects of environmental variables like temperature and viscosity on ciliary beating, synchronization, and three-dimensional helical swimming. We confirm and expand upon the existing understanding of these phenomena, for example determining that increasing viscosity promotes asynchronous beating. Motile cilia are subcellular organelles that propel microorganisms or direct fluid and particulate flow. Thus, cilia are critical to cell survival and human health. The unicellular algaChlamydomonas reinhardtiiis widely used to investigate the mechanisms underlying ciliary beating and coordination. However, freely swimming cells are difficult to image with sufficient resolution to capture cilia motion, necessitating that the cell body be held during experiments. Acoustic confinement is a compelling alternative to use of a micropipette, or to magnetic, electrical, and optical trapping that may modify the cells and affect their behavior. Beyond establishing our approach to studying microswimmers, we demonstrate a unique ability to mechanically perturb cells via rapid acoustic positioning.
more »
« less
Optimal ciliary locomotion of axisymmetric microswimmers
Many biological microswimmers locomote by periodically beating the densely packed cilia on their cell surface in a wave-like fashion. While the swimming mechanisms of ciliated microswimmers have been extensively studied both from the analytical and the numerical point of view, optimisation of the ciliary motion of microswimmers has received limited attention, especially for non-spherical shapes. In this paper, using an envelope model for the microswimmer, we numerically optimise the ciliary motion of a ciliate with an arbitrary axisymmetric shape. Forward solutions are found using a fast boundary-integral method, and the efficiency sensitivities are derived using an adjoint-based method. Our results show that a prolate microswimmer with a $$2\,{:}\,1$$ aspect ratio shares similar optimal ciliary motion as the spherical microswimmer, yet the swimming efficiency can increase two-fold. More interestingly, the optimal ciliary motion of a concave microswimmer can be qualitatively different from that of the spherical microswimmer, and adding a constraint to the cilia length is found to improve, on average, the efficiency for such swimmers.
more »
« less
- PAR ID:
- 10342558
- Date Published:
- Journal Name:
- Journal of Fluid Mechanics
- Volume:
- 927
- ISSN:
- 0022-1120
- Format(s):
- Medium: X
- Sponsoring Org:
- National Science Foundation
More Like this
-
-
Abstract Microscopic swimmers, both living and synthetic, often dwell in anisotropic viscoelastic environments. The most representative realization of such an environment is water-soluble liquid crystals. Here, we study how the local orientation order of liquid crystal affects the motion of a prototypical elliptical microswimmer. In the framework of well-validated Beris-Edwards model, we show that the microswimmer’s shape and its surface anchoring strength affect the swimming direction and can lead to reorientation transition. Furthermore, there exists a critical surface anchoring strength for non-spherical bacteria-like microswimmers, such that swimming occurs perpendicular in a sub-critical case and parallel in super-critical case. Finally, we demonstrate that for large propulsion speeds active microswimmers generate topological defects in the bulk of the liquid crystal. We show that the location of these defects elucidates how a microswimmer chooses its swimming direction. Our results can guide experimental works on control of bacteria transport in complex anisotropic environments.more » « less
-
Abstract The marine tintinnid ciliate Amphorides quadrilineata is a feeding-current feeder, creating flows for particle encounter, capture and rejection. Individual-level behaviors were observed using high-speed, high-magnification digital imaging. Cells beat their cilia backward to swim forward, simultaneously generating a feeding current that brings in particles. These particles are then individually captured through localized ciliary reversals. When swimming backward, cells beat their cilia forward (=ciliary reversals involving the entire ring of cilia), actively rejecting unwanted particles. Cells achieve path-averaged speeds averaging 3–4 total lengths per second. Both micro-particle image velocimetry and computational fluid dynamics were employed to characterize the cell-scale flows. Forward swimming generates a feeding current, a saddle flow vector field in front of the cell, whereas backward swimming creates an inverse saddle flow vector field behind the cell; these ciliary flows facilitate particle encounter, capture and rejection. The model-tintinnid with a full-length lorica achieves an encounter rate Q ~29% higher than that without a lorica, albeit at a ~142% increase in mechanical power and a decrease in quasi-propulsive efficiency (~0.24 vs. ~ 0.38). It is also suggested that Q can be approximated by π(W/2 + l)2U, where W, l and U represent the lorica oral diameter, ciliary length and swimming speed, respectively.more » « less
-
Respiratory cilia are important components in the lung defense mechanism. The coordinated beating of cilia cleans the airways of pathogens and foreign particles. We present a large-scale validation dataset of cilia motion for characterizing ciliary function. Ciliary beat frequency (CBF) is provided as benchmark metrics. The video dataset of cilia motion phenotypes contains four categories: temperatures, drugs and ACE2 manipulation. Under each category, mouse trachea samples were treated with different stimuli and imaged with a high-speed video microscope to acquire cilia motion. In addition, we generate ground truth masks labeling ciliary area for image segmentation. This validation dataset can serve as a benchmark for the computer vision community to develop models for analyzing ciliary beat pattern. This video dataset contains 872 videos and their ground-truth masks with the ciliary area labeled. The videos were recorded at 250 frames per second for 1 second. The image size is 800x800. Each pixel is 0.07987 μm. The csv file contains the CBF values of each video.more » « less
-
Abstract Maneuverable microswimmers/microdrones that navigate in hard-to-reach spaces inside human bodies hold a great potential for various biomedical applications. Acoustically actuated microswimmers have already demonstrated feasibility. However, for eventual translation of this technology, a robust 3-D tracking strategy for the microswimmer is particularly required. This paper presents our lab-designed 3-D ultrasound tracking system for real-time tracking of an acoustically actuated 3-D swimming microdrone. The ultrasound tracking system utilizing two ultrasound probes, a step motor and a host controller, was built to track the 3-D arbitrary motion of the microdrone in real-time. The performance of tracking was evaluated in the benchtop experiments by comparing the reconstructed trajectories with synchronized camera recordings. The ultrasound tracking system showed high reliability, with an average error of less than 0.3 mm across six different trials when compared to camera tracking. The results demonstrated the capability of our lab-designed 3-D ultrasound tracking system in accurately tracking the undetermined motion of the acoustic actuated 3-D swimming microdrone in real-time. The developed tracking system holds promise as a potential approach for biomedical applications and could pave the way for future clinical translation of the microswimmer technology.more » « less
An official website of the United States government

