skip to main content


Title: Phase 2: Gap Detailing in Drywall Partition Walls with Return Walls
Two partition walls with return walls at both ends and traditional slip-track detailing were investigated. Special gap details were evaluated to reduce damage at the wall intersection. The first detail utilized a large gap in the wall intersection, while the other detail utilized distributed gaps along the wall. The walls were tested under a bidirectional loading protocol, to provide better insight into the wall intersection behavior under bidirectional loading.  more » « less
Award ID(s):
1635363
NSF-PAR ID:
10348735
Author(s) / Creator(s):
; ; ; ;
Publisher / Repository:
Designsafe-CI
Date Published:
Subject(s) / Keyword(s):
["Phase 2: Structural and Non-Structural Subassemblies","Phase 1: Control and Sensors","Phase 2: Control and Sensors","Phase 2: Bidirectional loading","Phase 2: Experiment Setup Report","Atlss"]
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. null (Ed.)
    Drywall partition walls are susceptible to damage at low-level drifts, and hence reducing such damage is key to achieving seismic resiliency in buildings. Prior tests on drywall partition walls have shown that slip track connection detailing leads to better performance than other detailing, such as fully-fixed connections. However, in all prior testing, partition wall performance was evaluated using a unidirectional loading protocol (either in-plane or out-of-plane) or in shake table testing. Moreover, all details are susceptible to considerable damage to wall intersections. Two phases of the test have been performed at the Natural Hazards Engineering Research Infrastructure (NHERI) Lehigh Equipment Facility to develop improved details of drywall partition walls under bidirectional loading. The partition walls were tested alongside a cross-laminated timber (CLT) post-tensioned rocking wall subassembly, wherein the CLT system is under development as a resilient lateral system for tall timber buildings. In the Phase 1, the slip behavior of conventional slip-track detailing was compared to telescoping detailing (track-within-a-track deflection assembly). In the Phase 2, two details for reducing the wall intersection damage were evaluated on traditional slip-track C-shaped walls. First, a corner gap detail was tested. This detail incorporates a gap through the wall intersection to reduce the collision damage at two intersecting walls. Second, a distributed gap detail was tested. In this approach, the aim was to reduce damage by using more frequent control joints through the length of the wall. All walls were tested under a bidirectional loading protocol with three sub-cycles: in-plane, a bi-directional hexagonal load path, and a bi-directional hexagonal load path with an increase in the out-of-plane drift. This loading protocol allows for studying the bidirectional behavior of walls and evaluating the effect of out-of-plane drift on the partition wall resisting force. In the Phase 1, the telescoping detailing performed better than conventional slip track detailing because it eliminated damage to the framing. In Phase 2, the distributed gap detailing delayed damage to about 1% story drift. For the corner gap detailing, the sacrificial corner bead detached at low drifts, but the wall itself was damage-free until 2.5% drift. Bidirectional loading was found to have an insignificant influence on the in-plane resistance of the walls, and the overall resistance of the walls was trivial compared to the CLT rocking. 
    more » « less
  2. The slip behavior of two straight drywall partition walls (without return walls) – one with conventional slip-track detailing and the other with telescoping detailing – was examined. These drywall partition walls were tested under a bidirectional loading protocol, which allowed for systematic evaluation of the effect of out of plane drift on the in-plane resistance of the drywall partition walls. 
    more » « less
  3. This paper presents an experimental study on the multi-directional cyclic lateral-load response of post-tensioned self-centering (SC) cross-laminated timber (CLT) shear walls. The SC-CLT wall damage states are introduced and qualitatively defined in terms of the level of effort needed to repair the wall to restore its initial functional state. A comparison between SC-CLT wall damage states under unidirectional and multi-directional loading is presented. The experimental test results show that the SC-CLT wall damage state initiation occurs at lower story-drifts under multi-directional loading compared to unidirectional loading. The SC-CLT wall damage states are quantified in terms of the engineering demand parameter (EDP) defined as wall story-drift. Fragility functions that relate the conditional probability of the occurrence of a selected damage state at a wall corner to the EDP are developed. The results reinforce the observations that multi-directional loading on the CLT shear walls causes more damage that unidirectional loading. 
    more » « less
  4. Driven by demand for sustainable buildings and a reduction in construction time, mass timber buildings, specifically cross-laminated timber (CLT), is being more widely used in mid-rise buildings in the US. Low damage post-tensioned self-centering (SC) CLT shear walls (SC-CLT walls) provide an opportunity to develop seismically resilient CLT buildings. Previous research focused primarily on the lateral-load response under unidirectional loading of isolated self-centering timber walls, without considering the interaction with the adjacent building structural components, i.e., the floor diaphragms, collector beams, and gravity load system. Buildings response under seismic loading is multidirectional and there are concerns that multidirectional loading may be more damaging to SC-CLT wall panels and the adjacent building structural components than unidirectional loading, which affects the potential seismic resilience of buildings with SC-CLT walls. A series of lateral-load tests of a 0.625-scale timber sub-assembly was conducted at the NHERI Lehigh Large-Scale Multi-Directional Hybrid Simulation Experimental Facility to investigate the the lateral-load response and damage of SC-CLT walls and the capability of the adjacent building structural components i.e., the floor diaphragms, collector beams, and gravity load system to accommodate the building response and the controlled-rocking of the SC-CLT walls under multidirectional lateral loading. 
    more » « less
  5. To meet the increasing demand for high strength and non-combustible shear wall systems in mid-rise cold-formed steel (CFS) constructions, this paper investigates the seismic performance and design method of an innovative CFS shear wall system with in-frame corrugated steel sheathing based on previous studies. Shear wall and bearing wall specimens with in-frame corrugated steel sheathing are tested under combined lateral and gravity loading. Simplified numerical models of whole archetype buildings are established. The seismic performance evaluation is performed using methodology recommended in FEMA P695 and the seismic performance factors are examined. The test results show that the shear strength of the innovative shear wall is much higher than currently code certified wood-based shear walls in AISI S400. Also, the shear strength of bearing walls is approximately one-third of the shear strength of shear walls, which proves that bearing walls also contribute significant shear resistance in a structure. The seismic performance evaluation results verified that the existing seismic performance factors (R = Cd = 6.5 and [Formula: see text] = 3.0) for CFS shear walls with flat steel sheathings can also be used for the innovative shear wall system. The innovative CFS shear wall system with in-frame corrugated steel sheathing could be employed for mid-rise buildings in areas that are prone to high seismic and wind loads.

     
    more » « less