Title: Calibration method for an extended depth-of-field microscopic structured light system
This paper presents a calibration method for a microscopic structured light system with an extended depth of field (DOF). We first employed the focal sweep technique to achieve large enough depth measurement range, and then developed a computational framework to alleviate the impact of phase errors caused by the standard off-the-shelf calibration target (black circles with a white background). Specifically, we developed a polynomial interpolation algorithm to correct phase errors near the black circles to obtain more accurate phase maps for projector feature points determination. Experimental results indicate that the proposed method can achieve a measurement accuracy of approximately 1.0 μ m for a measurement volume of approximately 2,500 μ m (W) × 2,000 μ m (H) × 500 μ m (D).  more » « less
Award ID(s):
1763689
NSF-PAR ID:
10353123
Author(s) / Creator(s):
; ;
Date Published:
Journal Name:
Optics Express
Volume:
30
Issue:
1
ISSN:
1094-4087
Page Range / eLocation ID:
166
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. null (Ed.)
    We present new near-infrared VLTI/GRAVITY interferometric spectra that spatially resolve the broad Br γ emission line in the nucleus of the active galaxy IRAS 09149−6206. We use these data to measure the size of the broad line region (BLR) and estimate the mass of the central black hole. Using an improved phase calibration method that reduces the differential phase uncertainty to 0.05° per baseline across the spectrum, we detect a differential phase signal that reaches a maximum of ∼0.5° between the line and continuum. This represents an offset of ∼120  μ as (0.14 pc) between the BLR and the centroid of the hot dust distribution traced by the 2.3 μ m continuum. The offset is well within the dust sublimation region, which matches the measured ∼0.6 mas (0.7 pc) diameter of the continuum. A clear velocity gradient, almost perpendicular to the offset, is traced by the reconstructed photocentres of the spectral channels of the Br γ line. We infer the radius of the BLR to be ∼65  μ as (0.075 pc), which is consistent with the radius–luminosity relation of nearby active galactic nuclei derived based on the time lag of the H β line from reverberation mapping campaigns. Our dynamical modelling indicates the black hole mass is ∼1 × 10 8   M ⊙ , which is a little below, but consistent with, the standard M BH – σ * relation. 
    more » « less
  2. We develop optical calibration and distortion correction for a recently developed DMD-based volumetric aug- mented reality display. The display is capable of displaying imagery over a large volume — composed of 280 depth planes over a large depth-range (15 cm to 400 cm) and 40 degrees field-of-view. An unintended property of this display is that the field-of-view of the depth planes changes slightly over depth. This can cause distortions, perceptual errors for the perspective depth cue, and reduce the image quality slightly. To address these issues, we develop an optical calibration method and a distortion correction as a post-processing step to our rendering pipeline. 
    more » « less
  3. Abstract Sensitive dispersive readouts of single-electron devices (“gate reflectometry”) rely on one-port radio-frequency (RF) reflectometry to read out the state of the sensor. A standard practice in reflectometry measurements is to design an impedance transformer to match the impedance of the load to the characteristic impedance of the transmission line and thus obtain the best sensitivity and signal-to-noise ratio. This is particularly important for measuring large impedances, typical for dispersive readouts of single-electron devices because even a small mismatch will cause a strong signal degradation. When performing RF measurements, a calibration and error correction of the measurement apparatus must be performed in order to remove errors caused by unavoidable non-idealities of the measurement system. Lack of calibration makes optimizing a matching network difficult and ambiguous, and it also prevents a direct quantitative comparison between measurements taken of different devices or on different systems. We propose and demonstrate a simple straightforward method to design and optimize a pi matching network for readouts of devices with large impedance, $$Z \ge 1\hbox {M}\Omega$$ Z ≥ 1 M Ω . It is based on a single low temperature calibrated measurement of an unadjusted network composed of a single L-section followed by a simple calculation to determine a value of the “balancing” capacitor needed to achieve matching conditions for a pi network. We demonstrate that the proposed calibration/error correction technique can be directly applied at low temperature using inexpensive calibration standards. Using proper modeling of the matching networks adjusted for low temperature operation the measurement system can be easily optimized to achieve the best conditions for energy transfer and targeted bandwidth, and can be used for quantitative measurements of the device impedance. In this work we use gate reflectometry to readout the signal generated by arrays of parallel-connected Al-AlOx single-electron boxes. Such arrays can be used as a fast nanoscale voltage sensor for scanning probe applications. We perform measurements of sensitivity and bandwidth for various settings of the matching network connected to arrays and obtain strong agreement with the simulations. 
    more » « less
  4. Fromme, Paul ; Su, Zhongqing (Ed.)
    Three-dimensional digital image correlation (3D-DIC) has become a strong alternative to traditional contact-based techniques for structural health monitoring. 3D-DIC can extract the full-field displacement of a structure from a set of synchronized stereo images. Before performing 3D-DIC, a complex calibration process must be completed to obtain the stereovision system’s extrinsic parameters (i.e., cameras’ distance and orientation). The time required for the calibration depends on the dimensions of the targeted structure. For example, for large-scale structures, the calibration may take several hours. Furthermore, every time the cameras’ position changes, a new calibration is required to recalculate the extrinsic parameters. The approach proposed in this research allows determining the 3D-DIC extrinsic parameters using the data measured with commercially available sensors. The system utilizes three Inertial Measurement Units with a laser distance meter to compute the relative orientation and distance between the cameras. In this paper, an evaluation of the sensitivity of the newly developed sensor suite is provided by assessing the errors in the measurement of the extrinsic parameters. Analytical simulations performed on a 7.5 x 5.7 m field of view using the data retrieved from the sensors show that the proposed approach provides an accuracy of ~10-6 m and a promising way to reduce the complexity of 3D-DIC calibration. 
    more » « less
  5. Abstract

    When the observed data are contaminated with errors, the standard two‐sample testing approaches that ignore measurement errors may produce misleading results, including a higher type‐I error rate than the nominal level. To tackle this inconsistency, a nonparametric test is proposed for testing equality of two distributions when the observed contaminated data follow the classical additive measurement error model. The proposed test takes into account the presence of errors in the observed data, and the test statistic is defined in terms of the (deconvoluted) characteristic functions of the latent variables. Proposed method is applicable to a wide range of scenarios as no parametric restrictions are imposed either on the distribution of the underlying latent variables or on the distribution of the measurement errors. Asymptotic null distribution of the test statistic is derived, which is given by an integral of a squared Gaussian process with a complicated covariance structure. For data‐based calibration of the test, a new nonparametric Bootstrap method is developed under the two‐sample measurement error framework and its validity is established. Finite sample performance of the proposed test is investigated through simulation studies, and the results show superior performance of the proposed method than the standard tests that exhibit inconsistent behavior. Finally, the proposed method was applied to real data sets from the National Health and Nutrition Examination Survey. AnRpackageMEtestis available through CRAN.

     
    more » « less