Abstract A positive cloud‐to‐ground (+CG) lightning flash containing a single stroke with a peak current of approximately +310 kA followed by a long continuing current triggered seven upward lightning flashes from tall structures. The flashes were observed on 4 June 2016 at the Tall Object Lightning Observatory in Guangzhou, Guangdong Province, China. The optical and electric field characteristics of these flashes were analyzed using synchronized two‐station data from two high‐speed video cameras, one total‐sky lightning channel imager, two lightning channel imagers, and two sets of slow and fast electric field measuring systems. Three upward flashes were initiated sequentially in the field of view of high‐speed video cameras. One of them was initiated approximately 0.35 ms after the return stroke of +CG flash from the Canton Tower, the tallest structure within a 12‐km radius of the +CG flash, while the other two upward flashes were initiated from two other, more distant tall objects, approximately 18 ms after the +CG flash stroke. The initiation of the latter two upward flashes could be caused by the combined effect of the return stroke of +CG flash, its associated continuing current, and K process in the cloud. Each of these three upward flashes contained multiple downward leader/upward return stroke sequences, with the first leader/return stroke sequence of the second and third flashes occurring only after the completion of the last leader/return stroke sequence of the preceding flash. The total number of strokes in the three upward flashes was 13, and they occurred over approximately 1.5 s.
more »
« less
First High‐Speed Video Camera Observations of a Lightning Flash Associated With a Downward Terrestrial Gamma‐Ray Flash
Abstract In this paper, we present the first high‐speed video observation of a cloud‐to‐ground lightning flash and its associated downward‐directed Terrestrial Gamma‐ray Flash (TGF). The optical emission of the event was observed by a high‐speed video camera running at 40,000 frames per second in conjunction with the Telescope Array Surface Detector, Lightning Mapping Array, interferometer, electric‐field fast antenna, and the National Lightning Detection Network. The cloud‐to‐ground flash associated with the observed TGF was formed by a fast downward leader followed by a very intense return stroke peak current of −154 kA. The TGF occurred while the downward leader was below cloud base, and even when it was halfway in its propagation to ground. The suite of gamma‐ray and lightning instruments, timing resolution, and source proximity offer us detailed information and therefore a unique look at the TGF phenomena.
more »
« less
- PAR ID:
- 10435435
- Author(s) / Creator(s):
- ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; more »
- Publisher / Repository:
- DOI PREFIX: 10.1029
- Date Published:
- Journal Name:
- Geophysical Research Letters
- Volume:
- 50
- Issue:
- 14
- ISSN:
- 0094-8276
- Format(s):
- Medium: X
- Sponsoring Org:
- National Science Foundation
More Like this
-
-
Abstract We provide an updated analysis of the gamma ray signature of a terrestrial gamma ray flash (TGF) detected by the Fermi Gamma ray Burst Monitor first reported by Pu et al. (2020,https://doi.org/10.1029/2020GL089427). A TGF produced 3 ms prior to a negative cloud‐to‐ground return stroke was close to simultaneous with an isolated low‐frequency radio pulse during the leader’s propagation, with a polarity indicating downward moving negative charge. In previous observations, this “slow” low‐frequency signal has been strongly correlated with upward‐directed (opposite polarity) TGF events (Pu et al., 2019,https://doi.org/10.1029/2019GL082743; Cummer et al., 2011,https://doi.org/10.1029/2011GL048099), leading the authors to conclude that the Fermi gamma ray observation is actually the result of a reverse positron beam generating upward‐directed gamma rays. We investigate the feasibility of this scenario and determine a lower limit on the luminosity of the downward TGF from the perspective of gamma ray timing uncertainties, TGF Monte Carlo simulations, and meteorological analysis of a model storm cell and its possible charge structure altitudes. We determined that the most likely source altitude of the TGF reverse beam was 7.5 km ± 2.6 km, just below an estimated negative charge center at 8 km. At that altitude, the Monte Carlo simulations indicate a lower luminosity limit of 2 × 1018photons above 1 MeV for the main downward beam of the TGF, making the reverse beam detectable by the Fermi Gamma ray Burst Monitor.more » « less
-
Abstract This review covers selected results of recent observations of lightning discharges performed across the entire electromagnetic spectrum (radiofrequency, optical, and energetic radiation) at the Lightning Observatory in Gainesville, Florida. The most important results include (a) characterization of the preliminary-breakdown, stepped-leader, and return-stroke processes in high-intensity (⩾50 kA) negative lightning discharges, (b) the first high-speed video images of bidirectional leader that made contact with the ground and produced a return stroke, (c) discovery of negative stepped leader branches colliding with the lateral surface of neighboring branches of the same leader, (d) new data on the occurrence context and properties of compact intracloud discharges, and (e) observation of a terrestrial gamma-ray flash that occurred during a bipolar cloud-to-ground lightning discharge. The results serve to improve our understanding of the physics of lightning with important implications for lightning modeling, lightning protection, and high-energy atmospheric physics studies.more » « less
-
Abstract Using high‐speed video cameras operating with framing rates of 20 and 525 kfps, we imaged the attachment process of a natural negative cloud‐to‐ground flash, occurring at a distance of 490 m. Nine upward leaders were observed. A total of 12 space stems/leaders in 47 steps of the downward negative stepped leader were captured. The two‐dimensional length of them was between 2.0 and 5.9 m, with an average of 3.0 m. The average interstep interval, step length, and two‐dimensional speed of the downward negative leader and that of upward positive leader were statistically analyzed. The last step of the downward negative leader making contact with the upward connecting leader was recorded. The two‐dimensional length of the final imaged gap between the tips of opposite‐polarity leaders was estimated to be about 13 m.more » « less
-
Abstract On February 8, 2019, the Atmosphere‐Space Interaction Monitor observed a terrestrial gamma‐ray flash (TGF) and an Elve from a positive intracloud (+IC) lightning during the initial breakdown stage of a lightning flash north east of Puerto Rico. A second Elve produced by the return stroke (RS) of a negative cloud‐to‐ground (−CG) lightning was observed 456 ms later about 300 km south of the first one. Radio measurements show that a short (30 μs) and large (280 kA km) energetic in‐cloud pulse (EIP) produced the electromagnetic (EM) wave for the first Elve while the RS of the −CG was the EM source for the second Elve. Assuming that the EIP and the RS were the sources of the 777 nm emissions, both the delay relative to the ultra‐violet pulse and the shape and duration of the 777 nm emissions can be explained by scattering and absorption inside the clouds. The TGF produced by the +IC lightning had the same duration as the EIP (∼30 μs). Due to the ±80 μs timing uncertainty of the TGF, we can only state that TGF was produced just before or most likely simultaneously with the EIP. The large 777 nm pulse indicates that a large part of the EIP was produced by a current flowing in a hot channel, but it is likely that the TGF current also contributed significantly to the EIP.more » « less