skip to main content


Title: Transmission Line Parameter Estimation Under Non-Gaussian Measurement Noise
Accurate knowledge of transmission line parameters is essential for a variety of power system monitoring, protection, and control applications. The use of phasor measurement unit (PMU) data for transmission line parameter estimation (TLPE) is well-documented. However, existing literature on PMU-based TLPE implicitly assumes the measurement noise to be Gaussian. Recently, it has been shown that the noise in PMU measurements (especially in the current phasors) is better represented by Gaussian mixture models (GMMs), i.e., the noises are non-Gaussian. We present a novel approach for TLPE that can handle non-Gaussian noise in the PMU measurements. The measurement noise is expressed as a GMM, whose components are identified using the expectation-maximization (EM) algorithm. Subsequently, noise and parameter estimation is carried out by solving a maximum likelihood estimation problem iteratively until convergence. The superior performance of the proposed approach over traditional approaches such as least squares and total least squares as well as the more recently proposed minimum total error entropy approach is demonstrated by performing simulations using the IEEE 118-bus system as well as proprietary PMU data obtained from a U.S. power utility.  more » « less
Award ID(s):
2145063 1934766
PAR ID:
10454180
Author(s) / Creator(s):
; ;
Date Published:
Journal Name:
IEEE Transactions on Power Systems
Volume:
38
Issue:
4
ISSN:
0885-8950
Page Range / eLocation ID:
1 to 16
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. Accurate knowledge of transmission line parameters is essential for a variety of power system monitoring, protection, and control applications. The use of phasor measurement unit (PMU) data for transmission line parameter estimation (TLPE) is well-documented. However, existing literature on PMU-based TLPE implicitly assumes the measurement noise to be Gaussian. Recently, it has been shown that the noise in PMU measurements (especially in the current phasors) is better represented by Gaussian mixture models (GMMs), i.e., the noises are non-Gaussian. We present a novel approach for TLPE that can handle non-Gaussian noise in the PMU measurements. The measurement noise is expressed as a GMM, whose components are identified using the expectation-maximization (EM) algorithm. Subsequently, noise and parameter estimation is carried out by solving a maximum likelihood estimation problem iteratively until convergence. The superior performance of the proposed approach over traditional approaches such as least squares and total least squares as well as the more recently proposed minimum total error entropy approach is demonstrated by performing simulations using the IEEE 118-bus system as well as proprietary PMU data obtained from a U.S. power utility. 
    more » « less
  2. Recent studies indicate that the noise characteristics of phasor measurement units (PMUs) can be more accurately described by non-Gaussian distributions. Consequently, estimation techniques based on Gaussian noise assumptions may produce poor results with PMU data. This paper considers the PMU based line parameter estimation (LPE) problem, and investigates the performance of four state-of-the-art techniques in solving this problem in presence of non-Gaussian measurement noise. The rigorous comparative analysis highlights the merits and demerits of each technique w.r.t. the LPE problem, and identifies conditions under which they are expected to give good results. 
    more » « less
  3. The state estimation (SE) has been widely used in power system control centers to optimally estimate the states of the power grid in real time. Using different objective functions, many SE algorithms have been proposed to filter out measurement noise in different ways. In this paper, three widely-used SE algorithms, i.e., the weighted least squares (WLS), least absolute value (LAV), and projection statistics (PS) based algorithms, are compared in their estimation accuracy and computation time. The comparison was made using the simulation data generated from the IEEE 14-bus system and IEEE 118-bus system through the Monte-Carlo method. It is found that when the measurement noise is reasonably small and follows the independent Gaussian distribution, the WLS algorithm has the best accuracy and shortest computation time. When some measurements at leverage points were compromised by outliers, the PS based algorithm is the most robust among the three methods. The study results can be used to assist control centers in choosing the right SE algorithm based on the features of the measurement noise and setup. 
    more » « less
  4. Karakaya, Bora ; Collins, Randy (Ed.)
    With high penetration of inverter-based renewable energy sources (IBRES) power system dynamics began to occur within shorter time frames. However, existing monitoring tools that rely on phasor measurements lack sufficient resolution to monitor such fast transients in the grid. To address this issue, this paper proposes a weighted least absolute value (WLAV) estimation-based monitoring tool that uses the same discrete samples of measured voltages and currents that are used by the phasor measurement units (PMU). Such samples are in general not made available to the users by the PMUs but instead they are processed for a full or fraction of a cycle to obtain the positive sequence phasors. Given that these discrete samples are readily available, there is little reason not to use them for tracking fast voltage and current transients introduced by inverter-based renewable energy sources. Performance of the proposed estimator is illustrated using a small IEEE 30-bus system modeled using appropriate discrete-time components and simulated measurements with Gaussian noise as well as gross errors. 
    more » « less
  5. As the phasor measurement unit (PMU) placement problem involves a cost-benefit trade-off, more PMUs get placed on higher-voltage buses. However, this leads to the fact that many lower-voltage levels of the bulk power system cannot be observed by PMUs. This lack of visibility then makes time-synchronized state estimation of the full system a challenging problem. In this paper, a deep neural network-based state estimator (DeNSE) is proposed to solve this problem. The DeNSE employs a Bayesian framework to indirectly combine the inferences drawn from slow-timescale but widespread supervisory control and data acquisition (SCADA) data with fast-timescale but selected PMU data, to attain sub-second situational awareness of the full system. The practical utility of the DeNSE is demonstrated by considering topology change, non-Gaussian measurement noise, and detection and correction of bad data. The results obtained using the IEEE 118-bus system demonstrate the superiority of the DeNSE over a purely SCADA state estimator and a PMU-only linear state estimator from a techno-economic viability perspective. Lastly, the scalability of the DeNSE is proven by estimating the states of a large and realistic 2000-bus synthetic Texas system. 
    more » « less