skip to main content
US FlagAn official website of the United States government
dot gov icon
Official websites use .gov
A .gov website belongs to an official government organization in the United States.
https lock icon
Secure .gov websites use HTTPS
A lock ( lock ) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.


Title: Passively Tuning the Resonant Frequency of Kinetic Energy Harvesters Using Distributed Loaded Proof Mass
The inability to tune the frequency of MEMS vibration energy-harvesting devices is considered to be a major challenge which is limiting the use of these devices in real world applications. Previous attempts are either not compatible with microfabrication, have large footprints, or use complex tuning methods which consume power. This paper reports on a novel passive method of tuning the frequency by embedding solid microparticle masses into a stationary proof mass with an array of cavities. Altering the location, density, and volume of embedded solid filler will affect the resonant frequency, resulting in tuning capabilities. The experimental and computational validation of changing and tuning the frequency are demonstrated. The change in frequency is caused by varying the location of the particle filler in the proof mass to alter the center of gravity. The goal of this study was to experimentally and numerically validate the concept using macro-scale piezoelectric energy-harvesting devices, and to determine key parameters that affect the resolution and range of the frequency-tuning capabilities. The experimental results demonstrated that the range of the frequency tuning for the particular piezoelectric cantilever that was used was between 20.3 Hz and 49.1 Hz. Computational simulations gave similar results of 23.7 Hz to 49.4 Hz. However, the tuning range could be increased by altering the proof mass and cantilever design, which resulted in a tuning range from 144.6 Hz to 30.2 Hz. The resolution of tuning the frequency was <0.1 Hz  more » « less
Award ID(s):
2237086
PAR ID:
10493961
Author(s) / Creator(s):
;
Publisher / Repository:
MDPI
Date Published:
Journal Name:
Applied sciences
Volume:
14
Issue:
1
ISSN:
2076-3417
Page Range / eLocation ID:
156
Subject(s) / Keyword(s):
Energy harvesting tuning frequency piezoelectric/ embedded mass
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. Micro-scale kinetic energy harvesters are in large demand to function as sustainable power sources for wireless sensor networks and the Internet of Things. However, one of the challenges associated with them is their inability to easily tune the frequency during the manufacturing process, requiring devices to be custom-made for each application. Previous attempts have either used active tuning, which consumes power, or passive devices that increase their energy footprint, thus decreasing power density. This study involved developing a novel passive method that does not alter the device footprint or power density. It involved creating a proof mass with an array of chambers or cavities that can be individually filled with liquid to alter the overall proof mass as well as center of gravity. The resonant frequency of a rectangular cantilever can then be altered by changing the location, density, and volume of the liquid-filled mass. The resolution can be enhanced by increasing the number of chambers, whereas the frequency tuning range can be increased by increasing the amount of liquid or density of the liquids used to fill the cavities. A piezoelectric cantilever with a 340 Hz initial resonant frequency was used as the testing device. Liquids with varying density (silicone oil, liquid sodium polytungstate, and Galinstan) were investigated. The resonant frequencies were measured experimentally by filling various cavities with these liquids to determine the tuning frequency range and resolution. The tuning ranges of the first resonant frequency mode for the device were 142–217 Hz, 108–217 Hz, and 78.4–217 Hz for silicone oil, liquid sodium polytungstate, and Galinstan, respectively, with a sub Hz resolution. 
    more » « less
  2. Creating self-sustaining wireless sensor networks to power the Internet of Things requires universal energy harvesting systems. MEMS energy harvesters are in particular demand as they can be batch fabricated to meet the large supply demands. However, currently silicon MEMS kinetic energy harvesters are fabricated with a narrow bandwidth of 1–2 Hz, so each application requires a custom designed device which limits the advantages of batch fabrication. This paper investigates the development of a passive tuning MEMS vibration energy harvesting method that is based on distributing the load to various locations along the proof mass using a liquid load. A 3D printed proof mass with an array of cavities was developed, where each cavity could be filled with liquid to alter the resonant frequency as desired. Cavities were filled with silicone oil to validate the concept. The results illustrate tuning of the frequency with a resolution of < 1 Hz and a range of approximately 50 Hz. This method represents a passive tuning method as no power is required and the tuning can be accomplished during manufacturing so that one single universal energy harvester could be made and then tuned to meet the end user’s frequency specification. 
    more » « less
  3. null (Ed.)
    Acoustic/elastic metamaterials that rely on engineered microstructures instead of chemical composition enable a rich variety of extraordinary effective properties that are suited for various applications including vibration/noise isolation, high-resolution medical imaging, and energy harvesting and mitigation. However, the static nature of these elastic wave guides limits their potential for active elastic-wave guiding, as microstructure transformation remains a challenge to effectively apply in traditional elastic metamaterials due to the interplay of polarization and structural sensitivity. Here, a tunable, locally resonant structural waveguide is proposed and demonstrated for active vibration bandgap switching and elastic-wave manipulation between 1000–4000 Hz based on 3D printed building blocks of zinc-neutralized poly(ethylene- co -methacrylic acid) ionomer (Surlyn 9910). The ionomer exhibits shape memory behavior to enable rearrangement into new shape patterns through application of thermal stimuli that tunes mechanical performance in both space and time dimensions (4D metamaterial). The thermally induced shape-reorganization is programed to flip a series of frequency bands from passbands to bandgaps and vice versa . The continuously switched bandwidth can exceed 500 Hz. Consequently, altering the bandgap from “on” to “off” produces programmable elastic-wave propagation paths to achieve active wave guiding phenomena. An anisotropic cantilever-in-mass model is demonstrated to predict the self-adaptive dynamic responses of the printed structures with good agreement between the analytical work and experimental results. The tunable metamaterial-based waveguides illustrate the potential of 4D printed shape memory polymers in the designing and manufacturing of intelligent devices for elastic-wave control and vibration isolation. 
    more » « less
  4. VO2-based MEMS tunable optical shutters are demonstrated. The design consists of a VO2-based cantilever attached to a VO2-based optical window with integrated resistive heaters for individual mechanical actuation of the cantilever structure, tuning of the optical properties of the window, or both. Optical transmittance measurements as a function of current for both heaters demonstrates that the developed devices can be used as analog optical shutters, where the intensity of a light beam can be tuned to any value within the range of VO2phase transition. A transmittance drop off 30% is shown for the optical window, with tuning capabilities greater than 30% upon actuation of the cantilever. Unlike typical mechanical shutters, these devices are not restricted to binary optical states. Optical modulation of the optical window is demonstrated with an oscillating electrical input. This produces a transmittance signal that oscillates around an average value within the range off VO2’s phase transition. For an input current signal with fixed amplitude (fel= 0.28 Hz), tuned to be at the onset of the phase transition, a transmittance modulation of 14% is shown. Similarly, by modulating the DC-offset, a transmittance modulation of VO2along the hysteresis is obtained. 
    more » « less
  5. Atomic force microscopes (AFMs) are used not only to image with nanometer-scale resolution, but also to nanofabricate structures on a surface using methods such as dip-pen nanolithography (DPN). DPN involves using the tip of the AFM to deposit a small amount of material on the surface. Typically, this process is done in open loop, leading to large variations in the amount of material transferred. One of the first steps to closing this loop is to be able to accurately and rapidly measure the amount of deposition. This can be done by measuring the change in the resonance frequency of the cantilever before and after a write as that shift is directly related to the change in mass on the cantilever. Currently, this is done using a thermal-based system identification, a technique which uses the natural Brownian excitation of the cantilever as a white noise excitation combined with a fast Fourier transform to extract a Bode plot. However, thermal-based techniques do not have a good signal to noise ratio at typical cantilever resonance frequencies and thus do not provide the needed resolution in the DPN application. Here we develop a scheme that iteratively uses a stepped-sine approach. At each step of the iteration, three frequencies close to the approximate location of the resonance are injected and used to fit a model of the magnitude of the transfer function. The identified peak is used to select three new frequencies in a smaller range in a binary search to reduce the uncertainty of the measured resonance peak location. The scheme is demonstrated through simulation and shown to produce an accuracy of better than 0.5 Hz on a cantilever with a 14 kHz resonance in a physically realistic noise scenario. 
    more » « less