Nearly all frictional interfaces strengthen as the logarithm of time when sliding at ultra-low speeds. Observations of also logarithmic-in-time growth of interfacial contact area under such conditions have led to constitutive models that assume that this frictional strengthening results from purely time-dependent, and slip-insensitive, contact-area growth. The main laboratory support for such strengthening has traditionally been derived from increases in friction during “load-point hold” experiments, wherein a sliding interface is allowed to gradually self-relax down to subnanometric slip rates. In contrast, following step decreases in the shear loading rate, friction is widely reported to increase over a characteristic slip scale, independent of the magnitude of the slip-rate decrease—a signature of slip-dependent strengthening. To investigate this apparent contradiction, we subjected granite samples to a series of step decreases in shear rate of up to 3.5 orders of magnitude and load-point holds of up to 10,000 s, such that both protocols accessed the phenomenological regime traditionally inferred to demonstrate time-dependent frictional strengthening. When modeling the resultant data, which probe interfacial slip rates ranging from 3 . μ m · s − 1 . to less than 10 − 5 μ m · s − 1 , we found that constitutive models where low slip-rate friction evolution mimics log-time contact-area growth require parameters that differ by orders of magnitude across the different experiments. In contrast, an alternative constitutive model, in which friction evolves only with interfacial slip, fits most of the data well with nearly identical parameters. This leads to the surprising conclusion that frictional strengthening is dominantly slip-dependent, even at subnanometric slip rates.
more »
« less
Beyond quality and quantity: Spatial distribution of contact encodes frictional strength
Classically, the quantity of contact area AR between two bodies is considered a proxy for the force of friction. However, bond density across the interface—quality of contact—is also relevant, and contemporary debate often centers around the relative importance of these two factors. In this work, we demonstrate that a third factor, often overlooked, plays a significant role in static frictional strength: The spatial distribution of contact. We perform static friction measurements, μ, on three pairs of solid blocks while imaging the contact plane. By using linear regression on hundreds of image-μ pairs, we are able to predict future friction measurements with three to seven times better accuracy than existing benchmarks, including total quantity of contact area. Our model has no access to quality of contact, and we therefore conclude that a large portion of the interfacial state is encoded in the spatial distribution of contact, rather than its quality or quantity
more »
« less
- Award ID(s):
- 2011754
- PAR ID:
- 10500407
- Publisher / Repository:
- APS
- Date Published:
- Journal Name:
- Physical Review E
- Volume:
- 106
- Issue:
- 3
- ISSN:
- 2470-0045
- Format(s):
- Medium: X
- Sponsoring Org:
- National Science Foundation
More Like this
-
-
In order to improve the predictive abilities of weather and climate models, it is essential to understand the behaviour of wind stress at the ocean surface. Wind stress is contingent on small-scale interfacial dynamics typically not directly resolved in numerical models. Although skin friction contributes considerably to the total stress up to moderate wind speeds, it is notoriously challenging to measure and predict using physics-based approaches. This work proposes a supervised machine learning (ML) model that estimates the spatial distribution of the skin-friction drag over wind waves using solely wave elevation and wave age, which are relatively easy to acquire. The input–output pairs are high-resolution wave profiles and their corresponding surface viscous stresses collected from laboratory experiments. The ML model is built upon a convolutional neural network architecture that incorporates the Mish nonlinearity as its activation function. Results show that the model can accurately predict the overall distribution of viscous stresses; it captures the peak of viscous stress at/near the crest and its dramatic drop to almost null just past the crest in cases of intermittent airflow separation. The predicted area-aggregate skin friction is also in excellent agreement with the corresponding measurements. The proposed method offers a practical pathway for estimating both local and area-aggregate skin friction and can be easily integrated into existing numerical models for the study of air–sea interactions.more » « less
-
Abstract The potential lubrication mechanisms for articular cartilage remain as complex as the material itself. Many studies have examined systematically the effects of sliding velocity on the frictional response of cartilage, but a systematic analysis of probe curvature and contact area remains largely uncharted. Here, we explore this potential effect in three ways: a constant force experiment, a constant pressure experiment, and a nonconstant pressure and force experiment. Hard, impermeable spheres are used as probes and with sizes varied between 1.6 mm and 25.4 mm, allowing a sweep of physiologically relevant pressures. The aim is to effectively isolate the influence of probe curvature on the friction measurements. Articular cartilage samples were collected from horses at necropsy from the left and right distal and medial aspects of the radius. Each test was run for 5 min at a reciprocating sliding speed of 1 mm/s. Smaller probe diameters (and curvature) consistently resulted in high measured coefficients of friction of cartilage. Two lubrication regimes are observed during testing: an area-dependent regime at lower areas and an area-independent regime at higher areas. A power law (−1/3 to −1/2) relationship between friction coefficient and probe diameter is observed. Therefore, measurements made using different probe sizes will most likely result in different measurements of the friction behavior, and great care should be given when comparing these results.more » « less
-
Abstract This paper presents a high-resolution characterization of tool–chip interfacial stress distribution in cutting of a ductile metal using full-field photoelasticity. Our findings reveal the complex nature of stress distribution and friction along the contact, influenced by tool geometry. Notably, for negative rake-angle tools, the measurements reveal a distinct zone near the tool tip where the shear stress decreases as one travels toward the tool tip. Stress measurements are complemented within situvelocimetry of chip flow at the interface to enable correlation between stresses and velocity distribution at the interface. Based on the data, the tool–chip interface is categorized into three distinct zones: (1) a retardation zone near the tool tip, characterized by a high normal stress but small shear stresses, followed by (2) a uniform sliding zone with a relatively constant shear stress and (3) an elastic zone near the contact edge that obeys Coulomb friction. The paper challenges the customary practice of dividing the tool–chip contact into sticking and sliding zones and instead argues for a contact description, in terms of plastic and elastic zones that is more consistent with the experimental observations. The study also highlights the importance of high-resolutionin situcharacterization techniques for resolving the complex nature of friction in cutting and other similar sliding plastic contacts. Graphical abstractmore » « less
-
Abstract Accurate and (near) real-time earthquake monitoring provides the spatial and temporal behaviors of earthquakes for understanding the nature of earthquakes, and also helps in regional seismic hazard assessments and mitigations. Because of the increase in both the quality and quantity of seismic data, an automated earthquake monitoring system is needed. Most of the traditional methods for detecting earthquake signals and picking phases are based on analyses of features in recordings of an individual earthquake and/or their differences from background noises. When seismicity is high, the seismograms are complicated, and, therefore, traditional analysis methods often fail. With the development of machine learning algorithms, earthquake signal detection and seismic phase picking can be more accurate using the features obtained from a large amount of earthquake recordings. We have developed an attention recurrent residual U-Net algorithm, and used data augmentation techniques to improve the accuracy of earthquake detection and seismic phase picking on complex seismograms that record multiple earthquakes. The use of probability functions of P and S arrivals and potential P and S arrival pairs of earthquakes can increase the computational efficiency and accuracy of backprojection for earthquake monitoring in large areas. We applied our workflow to monitor the earthquake activity in southern California during the 2019 Ridgecrest sequence. The distribution of earthquakes determined by our method is consistent with that in the Southern California Earthquake Data Center (SCEDC) catalog. In addition, the number of earthquakes in our catalog is more than three times that of the SCEDC catalog. Our method identifies additional earthquakes that are close in origin times and/or locations, and are not included in the SCEDC catalog. Our algorithm avoids misidentification of seismic phases for earthquake location. In general, our algorithm can provide reliable earthquake monitoring on a large area, even during a high seismicity period.more » « less
An official website of the United States government

