Switchable radiative cooling based on the phase-change material vanadium dioxide (VO2) automatically modulates thermal emission in response to varying ambient temperature. However, it is still challenging to achieve constant indoor temperature control solely using a VO2-based radiative cooling system, especially at low ambient temperatures. Here, we propose a reverse-switching VO2-based radiative cooling system, assisting indoor air conditioning to obtain precise indoor temperature control. Unlike previous VO2-based radiative cooling systems, the reverse VO2-based radiative cooler turns on radiative cooling at low ambient temperatures and turns off radiative cooling at high ambient temperatures, thereby synchronizing its cooling modes with the heating and cooling cycles of the indoor air conditioning during the actual process of precise temperature control. Calculations demonstrate that our proposed VO2-based radiative cooling system significantly reduces the energy consumption by nearly 30 % for heating and cooling by indoor air conditioning while maintaining a constant indoor temperature, even surpassing the performance of an ideal radiative cooler. This work advances the intelligent thermal regulation of radiative cooling in conjunction with the traditional air conditioning technology.
more » « less- Award ID(s):
- 1941743
- PAR ID:
- 10511662
- Publisher / Repository:
- DE Gruyter
- Date Published:
- Journal Name:
- Nanophotonics
- Volume:
- 13
- Issue:
- 5
- ISSN:
- 2192-8614
- Page Range / eLocation ID:
- 701 to 710
- Format(s):
- Medium: X
- Sponsoring Org:
- National Science Foundation
More Like this
-
null (Ed.)Buildings use 40% of the global energy consumption and emit 30% of the CO2 emissions [1]. Of the total building energy, 30-40% are for building heating and cooling systems, which regulate the indoor thermal environment and provide thermal comfort to occupants. In the United States, most buildings use forced air technology to deliver heating/cooling to the targeted thermal zones. However, this system may cause complaints about thermal comfort from inhabitants due to excessive draft movement, inhomogeneous conditioning, and difficulty in accurately controlling the temperature for a system serving multiple rooms. Therefore, researchers have suggested using a radiant heating and cooling system as a better alternative to all-air systems to address these issues. Radiant systems supply heating or cooling directly to the building space using radiation released by the heated or cooled building enclosure via the embedded heating or cooling tubes. In the cooling season, the radiant system often works with a separated dehumidifier to meet space latent and sensible cooling load (called separate sensible and latent cooling system SSLC). The SSLC has shown higher efficiency than forced air systems. However, it is unsure whether the radiant heating and cooling system can provide better thermal comfort to occupants. Moreover, the evaluation method for thermal comfort in the current standard is suitable for forced air systems. Therefore, a new method shall be developed to evaluate the radiation system’s thermal comfort. In this paper, we review the experiment-based studies on the thermal comfort of radiant systems. According to the experimental studies regarding thermal comfort and radiant systems, the key findings are concluded to help guide the evaluation of thermal comfort for radiant systems.more » « less
-
Good indoor air quality in office environments is essential for occupant health and productivity. In open-plan offices, displacement ventilation has been recognized for its higher efficiency compared to mixing ventilation. This study evaluates the performance of displacement ventilation in an open-plan office under cooling and heating conditions, considering various supply ventilation rates, supply air temperatures, and occupancy levels. Field measurements were conducted over three months in a living laboratory office in a high-performance building. The indoor environment was controlled by an independent variable air volume (VAV) air conditioning system. The supply ventilation rate ranged from 6 to 12 h^−1. Real-time measurements of carbon dioxide (CO2) concentrations in the supply air, return air, and breathing zone of the office were conducted to assess occupants’ exposure to CO2 and ventilation efficiency. The results show that the supply ventilation rate plays an important role in shaping the air distribution and overall effectiveness of the mechanical ventilation system. Higher supply ventilation rates can enhance air distribution robustness, improving ventilation efficiency and reducing CO2 exposure under both cooling and heating conditions. These findings also suggest the need for an optimized control logic that differs from the conventional control logic used in VAV systems. Specifically, during the heating condition of displacement ventilation, it is recommended to maintain the supply ventilation rate at a higher level to effectively mitigate the impact of occupant behavior on air quality, minimize CO2 exposure risks, and ensure a more robust and reliable indoor air distribution.more » « less
-
Thermal comfort is a significant factor in the indoor building environment because it influences both human productivity and health. A currently popular method for predicting thermal comfort levels, the Predicted Mean Vote (PMV) and Predicted Percent Dissatisfied (PPD) model, unfortunately, has certain limitations. Consequently, the development of a better method for making accurate predictions (especially for individuals) is needed. Our goal was to develop a tool to predict individual thermal comfort preferences and automatically control the heating, ventilation, and air conditioning (HVAC) systems. This study adopted a series of human-subject experiments to collect essential data. All collected data was analyzed by adopting different machine learning algorithms. The machine learning algorithms predicted individual thermal comfort levels and thermal sensations, based on facial skin temperatures of participants in the experiments. These predictions were input data for the HVAC system control model, and results supported the potential for using facial skin temperatures to predict thermal comfort and thermal sensation levels. Moreover, this tool provided automatic control of the HVAC systems that can help improve the indoor environment of a building.more » « less
-
null (Ed.)In recent years, physiological features have gained more attention in developing models of personal thermal comfort for improved and accurate adaptive operation of Human-In-The-Loop (HITL) Heating, Ventilation, and Air-Conditioning (HVAC) systems. Pursuing the identification of effective physiological sensing systems for enhancing flexibility of human-centered and distributed control, using machine learning algorithms, we have investigated how heat flux sensing could improve personal thermal comfort inference under transient ambient conditions. We have explored the variations of heat exchange rates of facial and wrist skin. These areas are often exposed in indoor environments and contribute to the thermoregulation mechanism through skin heat exchange, which we have coupled with variations of skin and ambient temperatures for inference of personal thermal preferences. Adopting an experimental and data analysis methodology, we have evaluated the modeling of personal thermal preference of 18 human subjects for well-known classifiers using different scenarios of learning. The experimental measurements have revealed the differences in personal thermal preferences and how they are reflected in physiological variables. Further, we have shown that heat exchange rates have high potential in improving the performance of personal inference models even compared to the use of skin temperature.more » « less
-
Abstract Vanadium Dioxide (VO2) is a material that exhibits a phase transition from an insulating state to a metallic state at ≈68 °C. During a temperature cycle consisting of warming followed by cooling, the resistivity of VO2changes by several orders of magnitude over the course of the hysteresis loop. Using a focused laser beam (λ = 532 nm), it is shown that it is possible to optically generate micron‐sized metallic patterns within the insulating phase of a VO2planar junction which can be used to tune, on demand, the resistance of the VO2junction. A resistor network simulation is used to characterize the resulting resistance drops in the devices. These patterns persist while the base temperature is held constant within the hysteretic region while being easily removed totally by simply lowering the base temperature. Surprisingly, it is also observed that the pattern can be partially erased using an atomic force microscope (AFM) tip on the submicron scale. This erasing process can be qualitatively explained by the temperature difference between the VO2surface and the tip which acts as a local cooler. This optical and AFM resistive fine‐tuning offers the possibility of creating controllable synaptic weights between room‐temperature VO2neuristors.