Title: Predicting 3-D Lower Back Joint Load in Lifting: A Deep Pose Estimation Approach
Goal: Lifting is a common manual material handling task performed in the workplaces. It is considered as one of the main risk factors for work-related musculoskeletal disorders. An important criterion to identify the unsafe lifting task is the values of the net force and moment at L5/S1 joint. These values are mainly calculated in a laboratory environment, which utilizes marker-based sensors to collect three-dimensional (3-D) information and force plates to measure the external forces and moments. However, this method is usually expensive to set up, time-consuming in process, and sensitive to the surrounding environment. In this study, we propose a deep neural network (DNN)-based framework for 3-D pose estimation, which addresses the aforementioned limitations, and we employ the results for L5/S1 moment and force calculation. Methods: At the first step of the proposed framework, full body 3-D pose is captured using a DNN, then at the second step, estimated 3-D body pose along with the subject's anthropometric information is utilized to calculate L5/S1 join's kinetic by a top-down inverse dynamic algorithm. Results: To fully evaluate our approach, we conducted experiments using a lifting dataset consisting of 12 subjects performing various types of lifting tasks. The results are validated against a marker-based motion capture system as a reference. The grand mean ± SD of the total moment/force absolute errors across all the dataset was 9.06 ± 7.60 N·m/4.85 ± 4.85 N. Conclusion: The proposed method provides a reliable tool for assessment of the lower back kinetics during lifting and can be an alternative when the use of marker-based motion capture systems is not possible.  more » « less
Award ID(s):
1703883 1555408 1451292
PAR ID:
10085120
Author(s) / Creator(s):
; ; ; ; ;
Date Published:
Journal Name:
IEEE Transactions on Human-Machine Systems
Volume:
49
Issue:
1
ISSN:
2168-2291
Page Range / eLocation ID:
1 to 10
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. Excessive low back joint loading during material handling tasks is considered a critical risk factor of musculoskeletal disorders (MSD). Therefore, it is necessary to understand the low-back joint loading during manual material handling to prevent low-back injuries. Recently, computer vision-based pose reconstruction methods have shown the potential in human kinematics and kinetics analysis. This study performed L5/S1 joint moment estimation by combining VideoPose3D, an open-source pose reconstruction library, and a biomechanical model. Twelve participants lifting a 10 kg plastic crate from the floor to a knuckle-height shelf were captured by a camera and a laboratory-based motion tracking system. The L5/S1 joint moments obtained from the camera video were compared with those obtained from the motion tracking system. The comparison results indicate that estimated total peak L5/S1 moments during lifting tasks were positively correlated to the reference L5/S1 joint moment, and the percentage error is 7.7%. 
    more » « less
  2. This article presents an optimization formulation and experimental validation of a dynamic-joint-strength-based two-dimensional symmetric maximum weight-lifting simulation. Dynamic joint strength (the net moment capacity as a function of joint angle and angular velocity), as presented in the literature, is adopted in the optimization formulation to predict the symmetric maximum lifting weight and corresponding motion. Nineteen participants were recruited to perform a maximum-weight-box-lifting task in the laboratory, and kinetic and kinematic data including motion and ground reaction forces were collected using a motion capture system and force plates, respectively. For each individual, the predicted spine, shoulder, elbow, hip, knee, and ankle joint angles, as well as vertical and horizontal ground reaction force and box weight, were compared with the experimental data. Both root-mean-square error and Pearson’s correlation coefficient ( r) were used for the validation. The results show that the proposed two-dimensional optimization-based motion prediction formulation is able to accurately predict all joint angles, box weights, and vertical ground reaction forces, but not horizontal ground reaction forces. 
    more » « less
  3. We introduce HuMoR: a 3D Human Motion Model for Robust Estimation of temporal pose and shape. Though substantial progress has been made in estimating 3D human motion and shape from dynamic observations, recovering plausible pose sequences in the presence of noise and occlusions remains a challenge. For this purpose, we propose an expressive generative model in the form of a conditional variational autoencoder, which learns a distribution of the change in pose at each step of a motion sequence. Furthermore, we introduce a flexible optimization-based approach that leverages HuMoR as a motion prior to robustly estimate plausible pose and shape from ambiguous observations. Through extensive evaluations, we demonstrate that our model generalizes to diverse motions and body shapes after training on a large motion capture dataset, and enables motion reconstruction from multiple input modalities including 3D keypoints and RGB(-D) videos. 
    more » « less
  4. We introduce HuMoR: a 3D Human Motion Model for Robust Estimation of temporal pose and shape. Though substantial progress has been made in estimating 3D human motion and shape from dynamic observations, recovering plausible pose sequences in the presence of noise and occlusions remains a challenge. For this purpose, we propose an expressive generative model in the form of a conditional variational autoencoder, which learns a distribution of the change in pose at each step of a motion sequence. Furthermore, we introduce a flexible optimization-based approach that leverages HuMoR as a motion prior to robustly estimate plausible pose and shape from ambiguous observations. Through extensive evaluations, we demonstrate that our model generalizes to diverse motions and body shapes after training on a large motion capture dataset, and enables motion reconstruction from multiple input modalities including 3D keypoints and RGB(-D) videos. See the project page at geometry.stanford.edu/projects/humor. 
    more » « less
  5. Background Context: Pelvic ring fractures are becoming more common in the aging population and can prove to be fatal, having mortality rates between 10% and 16%. Stabilization of these fractures is challenging and often require immediate internal fixation. Therefore, it is necessary to have a biomechanical understanding of the different fixation techniques for pelvic ring fractures. Methods: A previously validated three-dimensional finite element model of the lumbar spine, pelvis, and femur was used for this study. A unilateral pelvic ring fracture was simulated by resecting the left side of the sacrum and pelvis. Five different fixation techniques were used to stabilize the fracture. A compressive follower load and pure moment was applied to compare different biomechanical parameters including range of motion (contralateral sacroiliac joint, L1-S1 segment, L5-S1 segment), and stresses (L5-S1 nucleus stresses, instrument stresses) between different fixation techniques. Results: Trans-iliac–trans-sacral screw fixation at S1 and S2 showed the highest stabilization for horizontal and vertical displacement at the sacral fracture site and reduction of contralateral sacroiliac joint for bending and flexion range of motion by 165% and 121%, respectively. DTSF (Double transiliac rod and screw fixation) model showed highest stabilization in horizontal displacement at the pubic rami fracture site, while the L5_PF_W_CC (L5-Ilium posterior screw fixation with cross connectors) and L5_PF_WO_CC (L5-Ilium posterior screw fixation without cross connectors) showed higher rod stresses, reduced L1-S1 (approximately 28%), and L5-S1 (approximately 90%) range of motion. Conclusions: Longer sacral screw fixations were superior in stabilizing sacral and contralateral sacroiliac joint range of motion. Lumbopelvic fixations displayed a higher degree of stabilization in the horizontal displacement compared to vertical displacement of pubic rami fracture, while also indicating the highest rod stresses. When determining the surgical approach for pelvic ring fractures, patient-specific factors should be accounted for to weigh the advantages and disadvantages for each technique. 
    more » « less