Title: Implementing Inertial Control for PMSG-WTG in Region 2 using Virtual Synchronous Generator with Multiple Virtual Rotating Masses
With the increasing integration of renewable energy, the problems associated with deteriorating grid frequency profile and potential power system instability have become more significant. In this paper, the inertial control algorithm using Virtual Synchronous Generator (VSG) is implemented on type-4 Permanent Magnet Synchronous Generator (PMSG) - wind turbine generator (WTG). The overall nonlinear dynamic model and its small-signal linearization of PMSG-WTG using VSG is established and comprehensively analyzed. Inevitably, the direct application of VSG introduces large inertia which causes conflict between the fast-varying of available wind power and inverter control with slow dynamics, particularly in region 2 of wind turbine. Aiming to address such issue, VSG with multiple virtual rotating masses is proposed in order to improve the active power tracking performance as well as to boost inertial control of a VSG. The inertial responses are verified in a modified 10MVA IEEE 14 bus microgrid system. The assessment of the simulation results demonstrates the applicability of VSG on renewable energy generation units.  more » « less
Award ID(s):
1711951
NSF-PAR ID:
10202218
Author(s) / Creator(s):
; ; ;
Date Published:
Journal Name:
2019 IEEE Power & Energy Society General Meeting (PESGM)
Page Range / eLocation ID:
1 to 5
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. With the proliferation of large-scale grid-connected wind farms, subsynchronous oscillation (SSO) incidents associated with Type-4 wind turbines (WTs) with a permanent magnet synchronous generator (PMSG) have occurred frequently. These incidents have caused severe reliability risks to the power grid. Conventionally, P-Q capability charts are utilized to ensure the safety operating region of a synchronous generator. However, a PMSG WT exhibits completely different and dynamic P-Q capability characteristics due to the difference in energy conversion technique and several critical factors related to the WT power converters. This paper presents a comprehensive dynamic P-Q capability study of a PMSG WT with sufficient and accurate considerations of the WT control and operation in the dq reference frame, its power converter constraints, and grid dynamics. Models of a PMSG WT are first developed based on its control principle in the dq reference frame. Then, algorithms for obtaining the P-Q capability charts of the WT are developed with the considerations of complete WT constraints in different aspects. The study analyzes the root cause of many abnormal operations of grid-connected PMSG WTs, reported in the literature, from the dynamic P-Q capability perspectives. The proposed study is verified via an electromagnetic transient (EMT) model of a grid-connected Type-4 WT.

     
    more » « less
  2. With the proliferation of large-scale grid-connected wind farms, subsynchronous oscillations (SSOs) incidents associated with Type-4 wind turbines (WTs) with a permanent magnet synchronous generator (PMSG) occurred frequently. These incidents have caused severe reliability risks to the power grid. Conventionally, P-Q capability charts are utilized to ensure the safety operating region of a synchronous generator. However, a PMSG WT exhibits a complete different and dynamic P-Q capability characteristics due to the difference in energy conversion technique and several other critical factors related to the power converters of the WT. This paper presents a comprehensive dynamic P-Q capability study of a PMSG WT with sufficient and accurate considerations of the WT control and operation in the dq reference frame, its specific power converter constraints, variable grid conditions, etc. Models of a PMSG WT are first developed based on its control principle in the dq reference frame. Then, algorithms for obtaining the P-Q capability charts of the WT are developed with the considerations of complete WT constraints in different aspects. The proposed study is verified via an electromagnetic transient (EMT) model of a grid-connected Type-4 WT. 
    more » « less
  3. Improved integration of wind farms into frequency regulation services is vital for increasing renewable energy production while ensuring power system stability. This work generalizes a recently proposed model-based receding horizon wind farm controller for secondary frequency regulation to arbitrary wind farm layouts and augments the controller to enable power modulation through storage of kinetic energy in the rotor. The new design explicitly includes actuation of blade pitch and generator torque, which facilitates implementation in existing farms as it takes advantage of current wind turbine control loops. This generalized control design improves control authority by individually controlling each turbine and using kinetic energy stored in the rotor in a coordinated manner to achieve farm level control goals. Numerical results demonstrate the effectiveness of this approach; in particular, the controller achieves accurate power tracking and reduces loss of revenue in the bulk power market by requiring less setpoint reduction (derate) than the power level control range. 
    more » « less
  4. Abstract

    This paper presents the genetic algorithm (GA) and particle swarm optimization (PSO) based frequency regulation for a wind‐based microgrid (MG) using reactive power balance loop. MG, operating from squirrel cage induction generator (SCIG), is employed for exporting the electrical power from wind turbines, and it needs reactive power which may be imported from the grid. Additional reactive power is also required from the grid for the load, directly coupled with such a distributed generator (DG) plant. However, guidelines issued by electric authorities encourage MGs to arrange their own reactive power because such reactive power procurement is defined as a local area problem for power system studies. Despite the higher cost of compensation, static synchronous compensator (STATCOM) is a fast‐acting FACTs device for attending to these reactive power mismatches. Reactive power control can be achieved by controlling reactive current through the STATCOM. This can be achieved with modification in current controller scheme of STATCOM. STATCOM current controller is designed with reactive power load balance for the proposed microgrid in this paper. Further, gain values of the PI controller, required in the STATCOM model, are selected first with classical methods. In this classical method, iterative procedures which are based on integral square error (ISE), integral absolute error (IAE), and integral square of time error (ISTE) criteria are developed using MATLAB programs. System performances are further investigated with GA and PSO based control techniques and their acceptability over classical methods is diagnosed. Results in terms of converter frequency deviation show how the frequency remains under the operating boundaries as allowed by IEEE standards 1159:1995 and 1250:2011 for integrating renewable‐based microgrid with grid. Real and reactive power management and load current total harmonic distortions verify the STATCOM performance in MG. The results are further validated with the help of recent papers in which frequency regulation is investigated for almost similar power system models. The compendium for this work is as following: (i) modelling of wind generator‐based microgrid using MATLAB simulink library, (ii) designing of STATCOM current controller with PI controller, (iii) gain constants estimation using classical, GA and PSO algorithm through a developed m codes and their interfacing with proposed simulink model, (v) dynamic frequency responses for proposed grid connected microgrid during starting and load perturbations, (vi) verification of system performance with the help of obtained real and reactive power management between STATCOM and grid, and (vii) validation of results with available literature.

     
    more » « less
  5. null (Ed.)
    With more and more renewable energy resources integrated into the power grid, the system is losing inertia because power electronics-based generators do not provide natural inertia. The low inertia will cause the microgrid to be more sensitive to disturbance and thus a small load change may result in a severe deviation in frequency. Based on the basic VSG algorithm, which is to mimic the characteristic of the traditional synchronous generator, the frequency can be controlled to a stable value faster and more smoothly when there is a fluctuation in the PV power generation and/or load change. However, characteristic of the VSG depends on the system structure in consideration of multiple generations, such as Synchronous Generator (SG), PV and Battery Energy Storage System (BESS), which greatly increases the complexity of applying VSG in practical power system. Furthermore, with BESS-VSG, Maximum Power Point (MPP) operation of PV is guaranteed. In addition, an adaptive VSG method is developed for a microgrid system, and the corresponding simulation in Matlab/Simulink shows the effectiveness of the adaptive VSG method. 