Title: Acoustic-resolution photoacoustic microscopy based on an optically transparent focused transducer with a high numerical aperture

This Letter reports acoustic-resolution-photoacoustic microscopy (AR-PAM) based on a new optically transparent focused polyvinylidene fluoride (PVDF) transducer with a high acoustic numerical aperture (NA) of 0.64. Owing to the improved fabrication process, the new transducer has a much higher NA (0.64) than the previously reported low-NA transducer (NA=0.23). The acoustic center frequency and (pulse-echo) bandwidth are also increased to 36 and 44 MHz, respectively, which provides a 38 µm acoustic focal spot size and 210 µm acoustic depth of focus. For demonstration, AR-PAM was conducted on a twisted wire target in water and chicken breast tissue, andin vivoon a mouse tail. The imaging results show that high acoustic resolution and sensitivity can be achieved with a simple and compact setup to resolve the target at different depths. Such capabilities can be useful for the development of new AR-PAM systems for handheld, wearable, and even endoscopic imaging applications.

 
more » « less
Award ID(s):
1925037 2036134
NSF-PAR ID:
10258376
Author(s) / Creator(s):
;
Publisher / Repository:
Optical Society of America
Date Published:
Journal Name:
Optics Letters
Volume:
46
Issue:
13
ISSN:
0146-9592; OPLEDP
Page Range / eLocation ID:
Article No. 3280
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. Capable of imaging blood perfusion, oxygenation, and flow simultaneously at the microscopic level, multi-parametric photoacoustic microscopy (PAM) has quickly emerged as a powerful tool for studying hemodynamic and metabolic changes due to physiological stimulations or pathological processes. However, the low scanning speed poised by the correlation-based blood flow measurement impedes its application in studying rapid microvascular responses. To address this challenge, we have developed a new, to the best of our knowledge, multi-parametric PAM system. By extending the optical scanning range with a cylindrically focused ultrasonic transducer (focal zone,76µ<#comment/>m×<#comment/>4.5mm) for simultaneous acquisition of 500 B-scans, the new system is 112 times faster than our previous multi-parametric system that uses a spherically focused transducer (focal diameter, 40 µm) and enables high-resolution imaging of blood perfusion, oxygenation, and flow over an area of4.5×<#comment/>1mm2at a frame rate of 1 Hz. We have demonstrated the feasibility of this system in the living mouse ear. Further development of this system into reflection mode will enable real-time cortex-wide imaging of hemodynamics and metabolism in the mouse brain.

     
    more » « less
  2. High-resolution strain sensing based on long, high-finesse fiber Fabry–Perot interferometers (FFPIs) has been demonstrated with a special focus on the infrasonic frequency range. A novel dual-FFPI scheme allows the large environment-induced background at low frequencies to be suppressed, permitting high strain resolution limited only by excess electronic noise. Noise-equivalent strain resolution of257pε<#comment/>/√<#comment/>Hzhas been achieved at 6 mHz, and the resolution improves to∼<#comment/>200fε<#comment/>/√<#comment/>Hzbetween 4–20 Hz. Without the use of any additional optical frequency references and with only off-the shelf commercial components, these resolutions are much better than most in the prior reports. Especially, an improvement of a factor of 1.8 is achieved in comparison with the highest resolution reported so far near 5 Hz. The limiting factors of the current scheme have been analyzed in detail, and the application prospects have been demonstrated using an acoustic transducer. The work lays out the potential of using long FFPIs with high finesse for high-resolution fiber-optic sensing in the infrasonic frequency range.

     
    more » « less
  3. Compound eyes found in insects provide intriguing sources of biological inspiration for miniaturized imaging systems. Inspired by such insect eye structures, we demonstrate an ultrathin arrayed camera enabled by a flat multi-level diffractive microlens array for super-resolution visible imaging. We experimentally demonstrate that the microlens array can achieve a large fill factor (hexagonal close packing withpitch=120µ<#comment/>m), thickness of 2.6 µm, and diffraction-limited (Strehlratio=0.88) achromatic performance in the visible band (450 to 650 nm). We also demonstrate super-resolution imaging with resolution improvement of∼<#comment/>1.4times by computationally merging 1600 images in the array.

     
    more » « less
  4. We experimentally demonstrate a camera whose primary optic is a cannula/needle (diameter=0.22mmandlength=12.5mm) that acts as a light pipe transporting light intensity from an object plane (35 cm away) to its opposite end. Deep neural networks (DNNs) are used to reconstruct color and grayscale images with a field of view of 18° and angular resolution of∼<#comment/>0.4∘<#comment/>. We showed a large effective demagnification of127×<#comment/>. Most interestingly, we showed that such a camera could achieve close to diffraction-limited performance with an effective numerical aperture of 0.045, depth of focus∼<#comment/>16µ<#comment/>m, and resolution close to the sensor pixel size (3.2 µm). When trained on images with depth information, the DNN can create depth maps. Finally, we show DNN-based classification of the EMNIST dataset before and after image reconstructions. The former could be useful for imaging with enhanced privacy.

     
    more » « less
  5. Improving the imaging speed of multi-parametric photoacoustic microscopy (PAM) is essential to leveraging its impact in biomedicine. However, to avoid temporal overlap, the A-line rate is limited by the acoustic speed in biological tissues to a few megahertz. Moreover, to achieve high-speed PAM of the oxygen saturation of hemoglobin, the stimulated Raman scattering effect in optical fibers has been widely used to generate 558 nm from a commercial 532 nm laser for dual-wavelength excitation. However, the fiber length for effective wavelength conversion is typically short, corresponding to a small time delay that leads to a significant overlap of the A-lines acquired at the two wavelengths. Increasing the fiber length extends the time interval but limits the pulse energy at 558 nm. In this Letter, we report a conditional generative adversarial network-based approach that enables temporal unmixing of photoacoustic A-line signals with an interval as short as∼<#comment/>38ns, breaking the physical limit on the A-line rate. Moreover, this deep learning approach allows the use of multi-spectral laser pulses for PAM excitation, addressing the insufficient energy of monochromatic laser pulses. This technique lays the foundation for ultrahigh-speed multi-parametric PAM.

     
    more » « less