Title: Vibration Analysis of a Piezoelectric Ultrasonic Atomizer to Control Atomization Rate
In this work, a mechanical vibrational analysis of an ultrasonic atomizer is carried out to control its atomization mass transfer rate. An ultrasonic atomizer is a device constructed with a piezoelectric ring coupled to a metallic circular thin plate with micro-apertures. The mechanism of mass transfer by atomization is a complex phenomenon to model because of the coupling effect between the fluid transfer and dynamic mechanics controlled by a piezoelectric vibrating ring element. Here, the effect of the micro-apertures shape of the meshed thin plate coupled to a piezoelectric ring during vibration, as well as the resonance frequency modes, are numerically studied using a finite element analysis and compared with theoretical and experimental results. Good correlations between the predicted and experimental results of the resonant frequencies and atomization rates were found.  more » « less
Award ID(s):
1762530
PAR ID:
10337846
Author(s) / Creator(s):
; ; ;
Date Published:
Journal Name:
Applied Sciences
Volume:
11
Issue:
18
ISSN:
2076-3417
Page Range / eLocation ID:
8350
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. null (Ed.)
    We study the enhanced atomization of viscous liquids by employing a novel two-fluid atomizer. The nozzle establishes a countercurrent flow configuration in which the gas and liquid are directed in opposite directions, establishing a two-phase mixing layer. Detailed measurements of droplet size distributions were carried out using laser shadowgraphy, along with high speed flow visualization. The measurements suggest that the liquid emerges as a spray with little further secondary atomization. The performance of this nozzle is compared to the ‘flow-blurring’ nozzle studied by other investigators for four test liquids of viscosity ranging from 1 to 133.5 mPa.s. The counterflow nozzle produces a spray whose characteristics are relatively insensitive to fluid viscosity over the range studied, for gas-liquid mass flow ratios between 0.25 and 1. To gain insight into the mixing process inside the nozzle, simulations are carried out using an Eulerian-Eulerian Volume of Fluid (VoF) approach for representative experimental conditions. The simulation reveals the detailed process of self-sustained flow oscillations and the physical mechanism that generate liquid filaments and final droplets. 
    more » « less
  2. Flow-blurring atomization is an innovative twin-fluid atomization approach that has demonstrated superior effectiveness in producing fine sprays compared to traditional airblast atomization methods. In flow-blurring atomizers, the high-speed gas flow is directed perpendicular to the liquid jet. Under specific geometric and physical conditions, the gas penetrates back into the liquid nozzle, resulting in a highly unsteady bubbly two-phase mixing zone. Despite the remarkable atomization performance of flow-blurring atomizers, the underlying dynamics of the two-phase flows and breakup mechanisms within the liquid nozzle remain poorly understood, primarily due to the challenges in experimental measurements of flow details. In this study, detailed interface-resolved numerical simulations are conducted to investigate the two-phase flows generated by a planar flow-blurring atomizer. By varying key dimensionless parameters, including the dynamic-pressure ratio, density ratio, and Weber number, over wide ranges, we aim to comprehensively characterize their effects on the two-phaseflow regimes and breakup dynamics. 
    more » « less
  3. The softening effect of ultrasonic vibration on pure copper is studied from a new perspective with micro-tensile tests, where the gauge length of the specimen is one order of magnitude smaller than the ultrasonic wavelength. With this configuration, the amount of flow stress reduction increases linearly with vibration amplitude whereas the flow stress reduction is insensitive to the studied strain rate ranging from 0.06/s to 1/s. Temperature rise associated with ultrasonic vibration is minimal from infrared thermal imaging. In situ digital image correlation (DIC) analysis shows strain localization near ultrasonic source whereas uniform strain distribution was observed during conventional tensile test. Optical microstructure characterization shows that area fraction of annealing twins in the deformed copper reduced from 3.3% to 1.8% with ultrasonic vibration. This is possibly attributed to enhanced interaction of dislocation between twin boundaries which act as non-regenerative dislocation source. Electron backscatter diffraction (EBSD) results show that ultrasonic vibration promotes preferential grain re-orientation and reduces the misorientation within grains. 
    more » « less
  4. We report a fiber-optic silicon Fabry–Perot temperature sensor with high speed by considering the end conduction effect, which refers to the unwanted heat transfer between the sensing element and the fiber stub delaying the sensor from reaching thermal equilibrium with the ambient environment. The sensor is constructed by connecting the narrow edge surface of a thin silicon plate to the edge of the microtube attached to the fiber tip. Compared to the traditional design where the silicon plate is attached to the fiber end face on its large plate surface, the new sensor design minimizes the heat transfer path to the fiber stub for improved sensor speed. It has the additional benefit of increased cavity length for improved resolution. We show that, compared with the sensor of traditional design, the sensor of the new design shortened the characteristic response time in still air from 83 ms to 13 ms and improved the sensor resolution by a factor of 12, from 0.15 K to 0.012 K. 
    more » « less
  5. One of the fundamental issues in the Fused Filament Fabrication (FFF) additive manufacturing process lies in the mechanical property anisotropy where the strength of the FFF-3D printed part in the build-direction can be significantly lower than that in other directions. The physical phenomenon that governs this issue is the coupled effect of macroscopic thermal mechanical issues associated with the thermal history of the interface, and the microscopic effect of the polymer microstructure and mass transfer across interfaces. In this study it was found that the use of 34.4 kHz ultrasonic vibrations during FFF-3D printing results in an increase of up to 10% in the interlayer adhesion in Acrylonitrile Butadiene Styrene (ABS), comparing the printing in identical thermal conditions to that in conventional FFF printing. This increase in the interlayer adhesion strength is attributed to the increase in polymer reptation due to ultrasonic vibration-induced relaxation of the polymer chains from secondary interactions in the interface regions. 