Title: Rapid detection of radiation susceptible regions in electronics
Radiation susceptibility of electronics has always been about probing electrical properties in either transient or time-accumulated phenomena. As the size and complexity of electronic chips or systems increase, detection of the most vulnerable regions becomes more time consuming and challenging. In this study, we hypothesize that localized mechanical stress, if overlapping electrically sensitive regions, can make electronic devices more susceptible to radiation. Accordingly, we develop an indirect technique to map mechanical and electrical hotspots to identify radiation-susceptible regions of the operational amplifier AD844 to ionizing radiation. Mechanical susceptibility is measured using pulsed thermal phase analysis via lock-in thermography and electrical biasing is used to identify electrically relevant regions. A composite score of electrical and mechanical sensitivity was constructed to serve as a metric for ionizing radiation susceptibility. Experimental results, compared against the literature, indicate effectiveness of the new technique in the rapid detection of radiation-vulnerable regions. The findings could be attractive for larger systems, for which traditional analysis would take —two to three orders of magnitude more time to complete. However, the indirect nature of the technique makes the study more approximate and in need for more consistency and validation efforts.  more » « less
Award ID(s):
2015795
PAR ID:
10507809
Author(s) / Creator(s):
; ; ; ;
Publisher / Repository:
American Vaccum Society
Date Published:
Journal Name:
Journal of Vacuum Science & Technology B
Volume:
41
Issue:
4
ISSN:
2166-2746
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. As electronic systems become larger and more complex, detection of the most vulnerable regions (MVR) to radiation exposure becomes more difficult and time consuming. We present a heuristic approach where the mechanical and thermal aspects of devices are exploited to quickly identify MVRs. Our approach involves the topological mapping of two device conditions. The first condition identifies regions with the highest mechanical strain or density of defects and interfaces via thermal wave probing and phase analysis. The second condition identifies regions with high electrical field. It is hypothesized that the region with the highest thermal wave penetration resistance and electrical field will exhibit the highest sensitivity to incoming radiation for single events and potentially, total ionizing dose. Our approach implements a simplistic design that improves analysis time by ∼2–3 orders of magnitude over current radiation sensitivity mapping methods. The design is demonstrated on the well-studied operational amplifier LM124, which shows agreement with the literature in identifying sensitive transistors–QR1, Q9, and Q18–with relatively high phase percentile values (>70%) and ΔT percentiles (>50%), satisfying conditions for elevated radiation susceptibility. This is followed by experimental results on a static random access memory (HM-6504) and a Xilinx Artix-7 35 T system on a chip. 
    more » « less
  2. Abstract Conductive adhesives are required for the integration of dissimilar material components to create soft electronic and robotic systems. Here, a heterogeneous liquid metal‐based conductive adhesive is developed that reversibly attaches to diverse surfaces with high stretchability (>100% strain), low modulus (<100 kPa), and strain‐invariant electrical conductivity. This SofT integrated composite with tacK through liquid metal (STICK‐LM) adhesive consists of a heterogeneous graded film with a liquid metal‐rich side that is embossed at prescribed locations for electrical conductivity and an electrically insulating adhesive side for integration. Adhesion behavior is tuned for adhesion energies > 70 Jm2(≈ 25x enhancement over unmodified composites) and described with a viscoelastic analysis, providing design guidelines for controllable yet reversible adhesion in electrically conductive systems. The architecture of STICK‐LM adhesives provides anisotropic and heterogeneous electrical conductivity and enables direct integration into soft functional systems. This is demonstrated with deformable fuses for robotic joints, repositionable electronics that rapidly attach on curvilinear surfaces, and stretchable adhesive conductors with nearly constant electrical resistance. This study provides a methodology for electrically conductive, reversible adhesives for electrical and mechanical integration of multicomponent systems in emerging technologies. 
    more » « less
  3. Abstract Radiation susceptibility of electronic devices is commonly studied as a function of radiation energetics and device physics. Often overlooked is the presence or magnitude of the electrical field, which we hypothesize to play an influential role in low energy radiation. Accordingly, we present a comprehensive study of low-energy proton irradiation on gallium nitride high electron mobility transistors (HEMTs), turning the transistor ON or OFF during irradiation. Commercially available GaN HEMTs were exposed to 300 keV proton irradiation at fluences varying from 3.76 × 1012to 3.76 × 1014cm2, and the electrical performance was evaluated in terms of forward saturation current, transconductance, and threshold voltage. The results demonstrate that the presence of an electrical field makes it more susceptible to proton irradiation. The decrease of 12.4% in forward saturation and 19% in transconductance at the lowest fluence in ON mode suggests that both carrier density and mobility are reduced after irradiation. Additionally, a positive shift in threshold voltage (0.32 V and 0.09 V in ON and OFF mode, respectively) indicates the generation of acceptor-like traps due to proton bombardment. high-resolution transmission electron microscopy and energy dispersive x-ray spectroscopy analysis reveal significant defects introduction and atom intermixing near AlGaN/GaN interfaces and within the GaN layer after the highest irradiation dose employed in this study. According toin-situRaman spectroscopy, defects caused by irradiation can lead to a rise in self-heating and a considerable increase in (∼750 times) thermoelastic stress in the GaN layer during device operation. The findings indicate device engineering or electrical biasing protocol must be employed to compensate for radiation-induced defects formed during proton irradiation to improve device durability and reliability. 
    more » « less
  4. Parametric amplification of ultrasmall signals from electromechanical transducers directly in the mechanical domain, prior to electrical readout, is an intriguing challenge and is important for both scientific measurements and technologies utilizing micro/nanoelectromechanical systems (MEMS/NEMS). Here, we report on parametric amplification of aluminum nitride (AlN) multimode NEMS resonators (with broad intrinsic dynamic ranges up to 90 dB) for enabling detection of their thermomechanical resonances in both optical and electrical readout schemes simultaneously. The experiments demonstrate that, upon parametric pumping, the electrically transduced thermomechanical motions experience significant amplification, surpassing the extrinsic electronic noise level, while still below the parametric pumping threshold. We achieve noise matching that enables room temperature force sensitivity of 0.46 fN/Hz1/2. We observe high parametric gain up to 650, accompanied by a strong boost (over 3.5×) in the effective quality factor (Qeff, from 9000 to 32 000). These findings underscore the utilities of parametric amplification in noise matching and improving force sensitivity for NEMS transducers and their emerging applications. 
    more » « less
  5. Abstract Electronic devices are ubiquitous in modern society, yet their poor recycling rates contribute to substantial economic losses and worsening environmental impacts from electronic waste (E‐waste) disposal. Here, recyclable and healable electronics are reported through a vitrimer‐liquid metal (LM) microdroplet composite. These electrically conductive, yet plastic‐like composites display mechanical qualities of rigid thermosets and recyclability through a dynamic covalent polymer network. The composite exhibits a high glass transition temperature, good solvent resistance, high electrical conductivity, and recyclability. The vitrimer synthesis proceeds without the need for a catalyst or a high curing temperature, which enables facile fabrication of the composite materials. The as‐synthesized vitrimer exhibits a fast relaxation time with reconfigurability and shape memory. The electrically conductive composite exhibits high electrical conductivity with LM volume loading as low as 5 vol.%. This enables the fabrication of fully vitrimer‐based circuit boards consisting of sensors and indicator LEDs integrated with LM‐vitrimer conductive wiring. Electrical self‐healing and thermally triggered material healing are further demonstrated with the composites. The vitrimer and LM‐composite provide a pathway toward fully recyclable, mechanically robust, and reconfigurable electronics, thus advancing the field of electronic materials. 