Title: Influence of Porous Inserts and Compact Resonators on Onset of Taconis Oscillations
Taconis oscillations represent excitation of acoustic modes due to large thermal gradients inside narrow tubes penetrating cryogenic vessels from a warm ambient environment. These oscillations are usually harmful, as they may drastically increase heat leakage into cryogenic vessels and result in strong vibrations of measuring instruments. Placing a porous material inside a tube with a goal to increase acoustic damping or attaching a small resonator to the main tube are some of the possible ways to suppress or mitigate Taconis effects. However, when the porous inserts are positioned in locations with large temperature gradients or the resonator parameters are selected incorrectly, these components may augment thermal-to-acoustic energy conversion and enhance Taconis oscillations. A low-amplitude thermoacoustic model has been extended and applied in this study to determine the effects of the insert location and pore radius, as well as the resonator dimensions, on the onset of Taconis phenomena in a hydrogen-filled tube of relevance to lines used in cryogenic hydrogen storage tanks. The presented findings can assist cryogenic specialists interested in suppressing or exciting Taconis oscillations.  more » « less
Award ID(s):
2214235
PAR ID:
10513000
Author(s) / Creator(s):
Publisher / Repository:
ASME
Date Published:
Journal Name:
Journal of Vibration and Acoustics
Volume:
146
Issue:
1
ISSN:
1048-9002
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. Acoustic oscillations in cryogenic systems can either be imposed intentionally, as in pulse-tube cryocoolers, or occur spontaneously due to Taconis-type thermoacoustic instabilities. To predict the propagation of sound waves in ducts with sudden changes in cross-sectional areas, minor losses associated with such transitions in oscillatory flows must be known. However, the current modeling approaches usually rely on correlations for minor loss coefficients obtained in steady flows, which may not accurately represent minor losses in sound waves. In this study, high-fidelity computational fluid dynamics simulations are undertaken for acoustic oscillations at transitions between tubes of different diameters filled with cryogenic hydrogen. The variable parameters include the tube diameter ratios, temperatures (80 K and 30 K), and acoustic impedances corresponding to standing and traveling waves. Computational simulation results are compared with reduced-order acoustic models to develop corrections for minor loss coefficients that describe transition losses in sound waves more precisely. The present findings can improve the accuracy of design calculations for acoustic cryocoolers and predictions of Taconis instabilities. 
    more » « less
  2. Abstract Lithium niobate is a promising material for developing quantum acoustic technologies due to its strong piezoelectric effect and availability in the form of crystalline thin films of high quality. However, at radio frequencies and cryogenic temperatures, these resonators are limited by the presence of decoherence and dephasing due to two-level systems. To mitigate these losses and increase device performance, a more detailed picture of the microscopic nature of these loss channels is needed. In this study, we fabricate several lithium niobate acoustic wave resonators and apply different processing steps that modify their surfaces. These treatments include argon ion sputtering, annealing, and acid cleans. We characterize the effects of these treatments using three surface-sensitive measurements: cryogenic microwave spectroscopy measuring density and coupling of TLS to mechanics, X-ray photoelectron spectroscopy and atomic force microscopy. We learn from these studies that, surprisingly, increases of TLS density may accompany apparent improvements in the surface quality as probed by the latter two approaches. Our work outlines the importance that surfaces and fabrication techniques play in altering acoustic resonator coherence, and suggests gaps in our understanding as well as approaches to address them. 
    more » « less
  3. Abstract Bulk acoustic resonators can be fabricated on the same substrate as other components and can operate at various frequencies with high quality factors. Mechanical dynamic metrology of these devices is challenging as the surface information available through laser Doppler vibrometry lacks information about the acoustic energy stored in the bulk of the resonator. Here we report the spin-acoustic control of naturally occurring negatively charged silicon monovacancies in a lateral overtone bulk acoustic resonator that is based on 4H silicon carbide. We show that acoustic driving can be used at room temperature to induce coherent population oscillations. Spin-acoustic resonance is shown to be useful as a frequency-tunable probe of bulk acoustic wave resonances, highlighting the dynamical strain distribution inside a bulk acoustic wave resonator at ambient operating conditions. Our approach could be applied to the characterization of other high-quality-factor microelectromechanical systems and has the potential to be used in mechanically addressable quantum memory. 
    more » « less
  4. Wind instruments containing a resonator (i.e., pipe) with an open end are expected to exhibit an acoustic standing wave characterized by a density oscillation whose amplitude falls to zero a short distance beyond the end of the resonator. An extrapolation of this amplitude based on the behavior inside the resonator yields an “effective” node of the standing wave (i.e., a point at which the extrapolated amplitude vanishes), and the distance from the end of the resonator to the location of this effective node (which is commonly referred to as simply a “node”) is known as the “end correction.” Recent work using a novel optical technique involving optical speckle patterns surprisingly suggested instead that a node is located inside the resonator with unexpected structure in the standing wave amplitude just beyond the end of the resonator. We have studied this problem by numerically solving the Navier-Stokes equations and find that the effective node of the density oscillation is located at the expected position outside the resonator with no unexpected structure in the functional form of the standing wave. We also show how pressure gradients and the flow pattern found near the end of the resonator can account for the unexpected behavior observed in the experiments. This sensitivity of optical interference effects to flow structure may give a new experimental way to investigate vorticity and other complex flows found in the mouthpiece of a musical instrument and in other situations. 
    more » « less
  5. TolTEC is an upcoming millimeter-wave imaging polarimeter designed to fill the focal plane of the 50-m-diameter Large Millimeter Telescope (LMT). Combined with the LMT, TolTEC will offer high-angular-resolution (5–10 ) simultaneous, polarization-sensitive observations in three wavelength bands: 1.1, 1.4, and 2.0 mm. Additionally, TolTEC will feature mapping speeds greater than 2 deg2∕mJy2∕h , thus enabling wider surveys of large-scale structure, galaxy evolution, and star formation. These improvements are only possible through the integration of approximately 7000 low-noise, high-responsivity superconducting Lumped Element Kinetic Inductance Detectors. Utilizing three focal planes of detector arrays requires the design, fabrication, and characterization of a unique, large-scale cryogenic system. Based on thermal models and expected photon loading, the focal planes must have a base operational temperature below 150 mK. To achieve this base temperature, TolTEC utilizes two cryocoolers, a Cryomech pulse tube cooler and an Oxford Instruments dilution refrigerator, to establish four thermal stages: 45 K, 4 K, 1 K, and 100 mK. During the design phase, we developed an object-oriented Python code to model the heat loading on each stage as well as the thermal gradients throughout the system. This model has allowed us to improve thermal gradients in the system as well as locate areas of poor thermal conductivity prior to ending a cooldown. The results of our model versus measurements from our cooldowns will be presented along with a detailed overview of TolTEC’s cryogenic system. We anticipate TolTEC to be commissioned at the LMT by Spring 2020. 
    more » « less