BackgroundLow back pain (LBP) is a significant public health problem that can result in physical disability and financial burden for the individual and society. Physical therapy is effective for managing LBP and includes evaluation of posture and movement, interventions directed at modifying posture and movement, and prescription of exercises. However, physical therapists have limited tools for objective evaluation of low back posture and movement and monitoring of exercises, and this evaluation is limited to the time frame of a clinical encounter. There is a need for a valid tool that can be used to evaluate low back posture and movement and monitor exercises outside the clinic. To address this need, a fabric-based, wearable sensor, Motion Tape (MT), was developed and adapted for a low back use case. MT is a low-profile, disposable, self-adhesive, skin-strain sensor developed by spray coating piezoresistive graphene nanocomposites directly onto commercial kinesiology tape. ObjectiveThe objectives of this study were to (1) validate MT for measuring low back posture and movement and (2) assess the acceptability of MT for users. MethodsA total of 10 participants without LBP were tested. A 3D optical motion capture system was used as a reference standard to measure low back kinematics. Retroreflective markers and a matrix of MTs were placed on the low back to measure kinematics (motion capture) and strain (MT) simultaneously during low back movements in the sagittal, frontal, and axial planes. Cross-correlation coefficients were calculated to evaluate the concurrent validity of MT strain in reference motion capture kinematics during each movement. The acceptability of MT was assessed using semistructured interviews conducted with each participant after laboratory testing. Interview data were analyzed using rapid qualitative analysis to identify themes and subthemes of user acceptability. ResultsVisual inspection of concurrent MT strain and kinematics of the low back indicated that MT can distinguish between different movement directions. Cross-correlation coefficients between MT strain and motion capture kinematics ranged from –0.915 to 0.983, and the strength of the correlations varied across MT placements and low back movement directions. Regarding user acceptability, participants expressed enthusiasm toward MT and believed that it would be helpful for remote interventions for LBP but provided suggestions for improvement. ConclusionsMT was able to distinguish between different low back movements, and most MTs demonstrated moderate to high correlation with motion capture kinematics. This preliminary laboratory validation of MT provides a basis for future device improvements, which will also involve testing in a free-living environment. Overall, users found MT acceptable for use in physical therapy for managing LBP.
more »
« less
Physical Therapists’ Acceptance of a Wearable, Fabric-Based Sensor System (Motion Tape) for Use in Clinical Practice: Qualitative Focus Group Study
BackgroundLow back pain (LBP) is a costly global health condition that affects individuals of all ages and genders. Physical therapy (PT) is a commonly used and effective intervention for the management of LBP and incorporates movement assessment and therapeutic exercise. A newly developed wearable, fabric-based sensor system, Motion Tape, uses novel sensing and data modeling to measure lumbar spine movements unobtrusively and thus offers potential benefits when used in conjunction with PT. However, physical therapists’ acceptance of Motion Tape remains unexplored. ObjectiveThe primary aim of this research study was to evaluate physical therapists’ acceptance of Motion Tape to be used for the management of LBP. The secondary aim was to explore physical therapists’ recommendations for future device development. MethodsLicensed physical therapists from the American Physical Therapy Association Academy of Leadership Technology Special Interest Group participated in this study. Overall, 2 focus groups (FGs; N=8) were conducted, in which participants were presented with Motion Tape samples and examples of app data output on a poster. Informed by the Technology Acceptance Model, we conducted semistructured FGs and explored the wearability, usefulness, and ease of use of and suggestions for improvements in Motion Tape for PT management of LBP. FG data were transcribed and analyzed using rapid qualitative analysis. ResultsRegarding wearability, participants perceived that Motion Tape would be able to adhere for several days, with some variability owing to external factors. Feedback was positive for the low-profile and universal fit, but discomfort owing to wires and potential friction with clothing was of concern. Other concerns included difficulty with self-application and potential skin sensitivity. Regarding usefulness, participants expressed that Motion Tape would enhance the efficiency and specificity of assessments and treatment. Regarding ease of use, participants stated that the app would be easy, but data management and challenges with interpretation were of concern. Physical therapists provided several recommendations for future design improvements including having a wireless system or removable wires, customizable sizes for the tape, and output including range of motion data and summary graphs and adding app features that consider patient input and context. ConclusionsSeveral themes related to Motion Tape’s wearability, usefulness, and ease of use were identified. Overall, physical therapists expressed acceptance of Motion Tape’s potential for assessing and monitoring low back posture and movement, both within and outside clinical settings. Participants expressed that Motion Tape would be a valuable tool for the personalized treatment of LBP but highlighted several future improvements needed for Motion Tape to be used in practice.
more »
« less
- Award ID(s):
- 2205093
- PAR ID:
- 10530529
- Publisher / Repository:
- JMIR Publications
- Date Published:
- Journal Name:
- JMIR Human Factors
- Volume:
- 11
- ISSN:
- 2292-9495
- Page Range / eLocation ID:
- e55246
- Format(s):
- Medium: X
- Sponsoring Org:
- National Science Foundation
More Like this
-
-
null (Ed.)Background According to the US Bureau of Labor Statistics, nurses will be the largest labor pool in the United States by 2022, and more than 1.1 million nursing positions have to be filled by then in order to avoid a nursing shortage. In addition, the incidence rate of musculoskeletal disorders in nurses is above average in comparison with other occupations. Robot-assisted health care has the potential to alleviate the nursing shortage by automating mundane and routine nursing tasks. Furthermore, robots in health care environments may assist with safe patient mobility and handling and may thereby reduce the likelihood of musculoskeletal disorders. Objective This pilot study investigates the perceived ease of use and perceived usefulness (acceptability) of a customized service robot as determined by nursing students (as proxies for nursing staff in health care environments). This service robot, referred to as the Adaptive Robotic Nurse Assistant (ARNA), was developed to enhance the productivity of nurses through cooperation during physical tasks (eg, patient walking, item fetching, object delivery) as well as nonphysical tasks (eg, patient observation and feedback). This pilot study evaluated the acceptability of ARNA to provide ambulatory assistance to patients. Methods We conducted a trial with 24 participants to collect data and address the following research question: Is the use of ARNA as an ambulatory assistive device for patients acceptable to nurses? The experiments were conducted in a simulated hospital environment. Nursing students (as proxies for nursing staff) were grouped in dyads, with one participant serving as a nurse and the other acting as a patient. Two questionnaires were developed and administrated to the participants based on the Technology Acceptance Model with respect to the two subscales of perceived usefulness and perceived ease of use metrics. In order to evaluate the internal consistency/reliability of the questionnaires, we calculated Cronbach alpha coefficients. Furthermore, statistical analyses were conducted to evaluate the relation of each variable in the questionnaires with the overall perceived usefulness and perceived ease of use metrics. Results Both Cronbach alpha values were acceptably high (.93 and .82 for perceived usefulness and perceived ease of use questionnaires, respectively), indicating high internal consistency of the questionnaires. The correlation between the variables and the overall perceived usefulness and perceived ease of use metrics was moderate. The average perceived usefulness and perceived ease of use metrics among the participants were 4.13 and 5.42, respectively, out of possible score of 7, indicating a higher-than-average acceptability of this service robot. Conclusions The results served to identify factors that could affect nurses’ acceptance of ARNA and aspects needing improvement (eg, flexibility, ease of operation, and autonomy level).more » « less
-
BackgroundLaypeople have easy access to health information through large language models (LLMs), such as ChatGPT, and search engines, such as Google. Search engines transformed health information access, and LLMs offer a new avenue for answering laypeople’s questions. ObjectiveWe aimed to compare the frequency of use and attitudes toward LLMs and search engines as well as their comparative relevance, usefulness, ease of use, and trustworthiness in responding to health queries. MethodsWe conducted a screening survey to compare the demographics of LLM users and nonusers seeking health information, analyzing results with logistic regression. LLM users from the screening survey were invited to a follow-up survey to report the types of health information they sought. We compared the frequency of use of LLMs and search engines using ANOVA and Tukey post hoc tests. Lastly, paired-sample Wilcoxon tests compared LLMs and search engines on perceived usefulness, ease of use, trustworthiness, feelings, bias, and anthropomorphism. ResultsIn total, 2002 US participants recruited on Prolific participated in the screening survey about the use of LLMs and search engines. Of them, 52% (n=1045) of the participants were female, with a mean age of 39 (SD 13) years. Participants were 9.7% (n=194) Asian, 12.1% (n=242) Black, 73.3% (n=1467) White, 1.1% (n=22) Hispanic, and 3.8% (n=77) were of other races and ethnicities. Further, 1913 (95.6%) used search engines to look up health queries versus 642 (32.6%) for LLMs. Men had higher odds (odds ratio [OR] 1.63, 95% CI 1.34-1.99; P<.001) of using LLMs for health questions than women. Black (OR 1.90, 95% CI 1.42-2.54; P<.001) and Asian (OR 1.66, 95% CI 1.19-2.30; P<.01) individuals had higher odds than White individuals. Those with excellent perceived health (OR 1.46, 95% CI 1.1-1.93; P=.01) were more likely to use LLMs than those with good health. Higher technical proficiency increased the likelihood of LLM use (OR 1.26, 95% CI 1.14-1.39; P<.001). In a follow-up survey of 281 LLM users for health, most participants used search engines first (n=174, 62%) to answer health questions, but the second most common first source consulted was LLMs (n=39, 14%). LLMs were perceived as less useful (P<.01) and less relevant (P=.07), but elicited fewer negative feelings (P<.001), appeared more human (LLM: n=160, vs search: n=32), and were seen as less biased (P<.001). Trust (P=.56) and ease of use (P=.27) showed no differences. ConclusionsSearch engines are the primary source of health information; yet, positive perceptions of LLMs suggest growing use. Future work could explore whether LLM trust and usefulness are enhanced by supplementing answers with external references and limiting persuasive language to curb overreliance. Collaboration with health organizations can help improve the quality of LLMs’ health output.more » « less
-
Abstract BackgroundWith the increasing integration of artificial intelligence (AI) into various aspects of daily life, there is a growing interest among designers and practitioners in incorporating AI into their fields. In health care domains like art therapy, AI is also becoming a subject of exploration. However, the use of AI in art therapy is still undergoing investigation, with its benefits and challenges being actively explored. ObjectiveThis study aims to investigate the integration of AI into art therapy practices to comprehend its potential impact on therapeutic processes and outcomes. Specifically, the focus is on understanding the perspectives of art therapists regarding the use of AI-assisted tools in their practice with clients, as demonstrated through the presentation of our prototype consisting of a deck of cards with words covering various categories alongside an AI-generated image. MethodsUsing a co-design approach, 10 art therapists affiliated with the American Art Therapy Association participated in this study. They engaged in individual interviews where they discussed their professional perspectives on integrating AI into their therapeutic approaches and evaluating the prototype. Qualitative analysis was conducted to derive themes and insights from these sessions. ResultsThe study began in August 2023, with data collection involving 10 participants taking place in October 2023. Our qualitative findings provide a comprehensive evaluation of the impact of AI on facilitating therapeutic processes. The combination of a deck of cards and the use of an AI-generated tool demonstrated an enhancement in the quality and accessibility of therapy sessions. However, challenges such as credibility and privacy concerns were also identified. ConclusionsThe integration of AI into art therapy presents promising avenues for innovation and progress within the field. By gaining insights into the perspectives and experiences of art therapists, this study contributes knowledge for both practical application and further research.more » « less
-
BackgroundFrequent sensor-assisted monitoring of changes in swallowing function may help improve detection of radiation-associated dysphagia before it becomes permanent. While our group has prototyped an epidermal strain/surface electromyography sensor that can detect minute changes in swallowing muscle movement, it is unknown whether patients with head and neck cancer would be willing to wear such a device at home after radiation for several months. ObjectiveWe iteratively assessed patients’ design preferences and perceived barriers to long-term use of the prototype sensor. MethodsIn study 1 (questionnaire only), survivors of pharyngeal cancer who were 3-5 years post treatment and part of a larger prospective study were asked their design preferences for a hypothetical throat sensor and rated their willingness to use the sensor at home during the first year after radiation. In studies 2 and 3 (iterative user testing), patients with and survivors of head and neck cancer attending visits at MD Anderson’s Head and Neck Cancer Center were recruited for two rounds of on-throat testing with prototype sensors while completing a series of swallowing tasks. Afterward, participants were asked about their willingness to use the sensor during the first year post radiation. In study 2, patients also rated the sensor’s ease of use and comfort, whereas in study 3, preferences were elicited regarding haptic feedback. ResultsThe majority of respondents in study 1 (116/138, 84%) were willing to wear the sensor 9 months after radiation, and participant willingness rates were similar in studies 2 (10/14, 71.4%) and 3 (12/14, 85.7%). The most prevalent reasons for participants’ unwillingness to wear the sensor were 9 months being excessive, unwanted increase in responsibility, and feeling self-conscious. Across all three studies, the sensor’s ability to detect developing dysphagia increased willingness the most compared to its appearance and ability to increase adherence to preventive speech pathology exercises. Direct haptic signaling was also rated highly, especially to indicate correct sensor placement and swallowing exercise performance. ConclusionsPatients and survivors were receptive to the idea of wearing a personalized risk sensor for an extended period during the first year after radiation, although this may have been limited to well-educated non-Hispanic participants. A significant minority of patients expressed concern with various aspects of the sensor’s burden and its appearance. Trial RegistrationClinicalTrials.gov NCT03010150; https://clinicaltrials.gov/study/NCT03010150more » « less
An official website of the United States government

